| Product Name | Notes |
|---|---|
| The M100 series current transducers are designed to measure A.C. Current in single and 3 phase systems. They convert the A.C. signal to a D.C. Output that is directly proportional... | |
| The M100 series of frequency transducers are designed to measure frequency in single and 3 phase systems. The A.C. Input is converted to a D.C. Output, that is directly proportional... | |
| The M100 series voltage transducers are designed to measure A.C. Voltage in single and 3 phase system. They convert the A.C. Signal to a D.C. Output that is directly proportional... | |
| The M100-AAS and M100-ALS are A.C. Current summation transducers. Both can have up to 3 inputs of either 1, 5 or 10 amps. These inputs are summed by the transducer... | |
| The M100-AX1 and AX3 are essentially the same as the M100-AA1 and AA3, but they have auxiliaries which allows the working range to be 0-125% rather than 10-125%. Used where... | |
| The M100-DS series of summation transducer take up to four inputs and provide an output signal directly proportional to the sum of the inputs. A typical application is the summation... | |
| The M100-FE1 measure the frequency of the input signal and provides a DC output that is directly proportional to the input frequency. The FE1 can accept frequency or pulse inputs... | |
| The M100-PA series of phase angle transducers measure the phase angle between current and voltage. They can be used on single and 3 phase 3 or 4 wire balanced systems. | |
| The M100-RPN is designed to measure the resistance of 3 wire potentiometers, where the resistance value is proportional to the position of the wiper of the potentiometer. The output value... | |
| The M100-RTD monitors the resistance of either 100 Ohm Platinum, or 120 Ohm Nickel. The RTDs resistance increase as the temperature rises, this resistance change is detected by the M100-RTD,... | |
| The M100-TAP measures the value of resistance on tap position changers, typically used on high voltage transformers. Each position on the selector has an equal value of resistance so that... | |
| The M100-TJ1 and TK1 measure the millivolt drop of J and K type thermocouples respectively. Thermocouples are made from two dissimilar metals and as the temperature rises, the mV across... | |
| The M100-VS1 is a self powered voltage transducer. The suppression allows the transducer to accurately measure a voltage system over a narrow band either side of a nominal voltage. The... | |
| The M100-WA series measure active power in single, 3 phase 3 or 4 wire balanced and unbalanced systems. Using the time division multiplier circuit means that they can be used... | |
| The M100-XA series measure reactive power in single, 3 phase 3 or 4 wire balanced and unbalanced systems. Using the time division multiplier circuit means that they can be used... | |
| The M700 series are 2 wire transmitters. The M700-AL1 converts the A.C. Input current signal to a 4-20mA D.C. Output. The output is directly proportional to the input signal. 2... | |
| The M700 series are 2 wire transmitters. The M700-VL1 converts the A.C. input voltage signal to a 4-20mA D.C. Output. The output is directly proportional to the input signal. 2... |