Hamilton Company Datasheets for Syringes and Needles
Syringes utilize a cylinder and plunger for precise delivery of liquids or gases in analytical, medical, pharmaceutical or biotechnology applications. Many times needles are included with the syringe.
Syringes and Needles: Learn more
| Product Name | Notes |
|---|---|
| At the heart of a Microlab 500 instrument is the Hamilton Gastight syringe. The precision glass barrel and finely machined polymer components result in unmatched precision and accuracy. Additionally the... | |
| For over 50 years Hamilton has been the trusted partner for robotic and clinical diagnostic instrumentation. Our syringes provide the accuracy and precision that enables many of the automated processes... | |
| Gastight syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes... | |
| Gel electrophoresis is used in forensics, molecular biology, genetics, microbiology and biochemistry. The results can be analyzed quantitatively by visualizing the gel with UV light and a gel imaging device. | |
| Hamilton Company offers a calibration service for precision syringes and Digital Syringes. A Certificate of Calibration is provided with the product and the procedure is performed with an unbroken chain... | |
| Hamilton offers two quality syringe options for the Autosystem and Clarus 500 GCs Autosamplers. | |
| Hamilton's PTFE tipped plungers set the standard for quality and reliability. Process improvements over the past 5 years have enabled a 7-10 fold improvement in syringe life when used in... | |
| Hat type needles are designed to be connected directly to a flat bottom valve port. Use the Needle Bushing part number 35056 to connect the needle directly to any 1/4-28... | |
| In order to meet user requirements, as HPLC applications continue to diversify, two new models, the SIL-10AF and the SIL-10AP, have been added to the Shimadzu High Performance Liquid Chromatograph... | |
| Kel-F hub (KF) needles can be used with Luer Tip (LT) and PTFE Luer Lock (TLL) syringes and connectors. Standard needle length is 2" / 51 mm. Kel-F hub (KF)... | |
| Large Hub Removable (RN) needles can be used with removable (RN)-style syringes that are 250 μL and larger. Standard needle length is 2" / 51 mm. Removable (RN) needles are... | |
| Long-life syringes were developed for extreme conditions that include harsh chemicals as well as abrasive particulate matter. The plunger tip is made from UHMWPE (Ultra High Molecular Weight Poly Ethylene)... | |
| Metal hub (nickel plated brass) needles can be used with TLL syringes and LT or TLL connectors. The needles are 304 stainless steel. Standard needle length is 2" / 51... | |
| Multi-Channel Gel Loading Syringes are designed for multiplex DNA sequencing methodologies. You can rapidly transfer 8 or 12 samples to sequencing gels, MICROTITER® plates or nylon membranes. It accurately... | |
| Pipette Controllers are intended to be used in place of rubber bulbs to easily and precisely fill glass pipettes. The free-sliding plunger coarsely fills the pipette, and the knurled plunger... | |
| Small Hub Removable (RN) needles can be used with removable (RN)-style syringes that are 100 μL and smaller. Standard needle length is 2" / 51 mm. Removable (RN) needles are... | |
| Split/splitless injection consists of a heated chamber with a glass liner into which the sample is injected through the septum. A microsyringe is used to inject the sample through a... | |
| Syringes for U6K valve come with a 25s gauge needle specifically designed for this valve. 16 Syringes for Waters U6K Injection Valve One priming syringe for Waters 510 HPLC pump... | |
| Syringes for Valco VISF-1 Injection Valves | |
| The 1000 series syringes are a mid volume Gastight syringe. This series of syringes is ideal for dispensing volumes from 100 μL up to 100 mL. A variety of different... | |
| The 1700 series syringes are the Gastight version of the original 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. | |
| The 1800 series syringes are the reinforced plunger version of the 1700 series syringes. Attached to the flange of the syringe is a blue Syringe Holder. The Syringe Holder provides... | |
| The 600 series syringes are a half stroke version of the original 700 series syringes. This series of syringes is ideal for dispensing volumes from 0.25 μL up to 5... | |
| The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different... | |
| The 7000 series syringes are considered modified Microliter syringes for their unique design. This series of syringes is ideal for dispensing volumes from 0.05 μL up to 5 μL. The... | |
| The 7693A builds on the proven Agilent Autosampler technologies that have worked reliably for customers in the past, including dual simultaneous injection and patented fast injection. The 7693A takes it... | |
| The 800 series syringes are the reinforced plunger version of the original 700 series syringes. Attached to the flange of the syringe is a blue Syringe Holder. The Syringe Holder... | |
| The 900 series syringe is the economical version of the 800 series syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 10 μL. The... | |
| The CR700 Constant Rate Syringes have preset volumes that can be dispensed at a constant flow rate. The volume is adjustable with a precise adjustable micrometer screw. The adjusted volume... | |
| The Hamilton Super Syringe is a large volume Gastight syringe. These syringes are ideal for dispensing volumes from 50 mL up to 2 L. The Super Syringe is the only... | |
| The thin layer chromatography (TLC) needles are coated with PTFE 3/4" up the needle from the tip. The coating reduces the surface tension between the needle and the liquid making... | |
| The VDRL Antigen Test is a microscopic nontreponemal flocculation test to be used for the detection of reagin. The procedure is based on the VDRL antigen being combined at a... | |
| These are replacement needles for the fixed width Gel Loading Syringe. The needles are available in 0.2, 0.3, and 0.4 mm outer diameters. The 0.2 and 0.3 mm needles are... | |
| Threaded Plunger Syringes are for applications requiring extremely precise plunger movement or minute fluid manipulation. The Luer tip (LT) syringe terminations allow easy connection of Kel-F® hub needles; Kel-F... |
| << Prev | Next >> |