CSA Group Datasheets for Standards and Technical Documents
Standards and technical documents includes standards, codes, regulation, handbooks, manuals, comprehensive guides and other formal publications. Standards, codes, and regulation establish uniform specifications, procedures or technical criteria.
Standards and Technical Documents: Learn more
| Product Name | Notes |
|---|---|
| Adds new clauses dealing with intermediate frequency and differential gain and phase characteristics. | |
| Applicable to d.c. potentiometers assembled from resistors and switches and operating entirely on direct current, having accuracy classes of 0.0005 ... 0.1, as well as to auxiliary equipment which is... | |
| Applicable to d.c. resistive volt ratio boxes with fixed ratios having a ratio input voltage up to 1.5 kV and a class index of 0.1 or better, as well as... | |
| Applicable to non-dispersive infra-red analyzers specified for installation either indoors or outdoors and used for the continuous determination of certain aspects of air quality by measuring the gaseous constituents. Special... | |
| Applicable to post insulators of organic material for indoor service in electrical installations or equipment operating in air at atmospheric pressure on alternating current with a nominal voltage greater than... | |
| Applicable to testing of towers and structures of overhead lines for voltages above 45 kV. Codifies methods of tests. | |
| Applies specifically to antennas used for transmitting and receiving in the mobile services. Defines terms and conditions of measurement used to ascertain the performance of antennas within the scope of... | |
| Applies to a group of related rectangular, multicontact, two-part printed board connectors with male and female contacts in conjunction with either solder or solderless terminations (such as wrap type). All... | |
| Applies to a group of related two-part connectors for printed boards for board-to-board and board-to-wire connection, with tin or gold plated contact area according to the style. The free or... | |
| applies to all types of industrial-process control valves (hereinafter referred to as control valves). This part establishes a partial basic terminology list and provides guidance on the use of all... | |
| Applies to antennas used in satellite earth stations. Describes methods of measurement of cross-polarization discrimination and power gain. Contains appendices dealing with error analysis and gain measurement accuracy. | |
| Applies to cellulosic papers for electrical purposes. It specifies the methods of test to be used in testing cellulosic papers for electrical purposes to meet the requirements prescribed in the... | |
| Applies to circular connectors for low-frequency audio and video applications such as audio, video and audio-visual equipment. Specifies dimensions, general requirements and tests. | |
| Applies to coaxial connectors associated with electrical measuring instruments used in nuclear instrumentation. Establishes standard dimensions of the mating parts, construction and mounting rules, voltage rating and test voltages, mininium... | |
| Applies to coupling devices for power line carrier (PLC) systems which are connected between the coupling capacitor(s) and the carrier-frequency connection to the PLC terminal and gives requirements for safety,... | |
| Applies to crêped kraft insulating papers, either hard and made from base papers of low or medium permeability, or soft, porous, made from base papers of high permeability. | |
| Applies to electric coffee makers for household use, not commercial or industrial use. It defines the main performance characteristics which are of interest to the user and describes the standard... | |
| Applies to electric kettles and jugs with a capacity up to 2,5 l. States and defines the principal performance characteristics which are of interest to the user and describes the... | |
| Applies to electric storage heaters intended to heat the room in which they are located. It defines the main performance characteristics and describes methods for measuring these characteristics. It does... | |
| Applies to electrically operated food preparation appliances for household use. States and defines test methods for measuring the functions that can be done by means of household electrical food preparation... | |
| Applies to electroheat installations for remelting and, in some cases, for refining processes of metals through direct resistance heating of a conductive slag. To be used in conjunction with IEC... | |
| Applies to frequency division multiplex multiple-access/freq uency-modulated systems. Gives methods of measurement for return loss, input and output levels, amplitude/frequency characteristic, static automatic gain control characteristic and 'group-delay/frequen cy characteristic'. | |
| Applies to instruments designed primarily for the measurement of acoustic impedance/admittance in the human external acoustic meatus using a stated probe tone. It is recognized that other probe signals may... | |
| applies to interface systems used to interconnect both programmable and nonprogrammable electronic measuring apparatus with other apparatus and accessories necessary to assemble instrumentation systems. It applies to the interface of... | |
| Applies to loudspeakers and loudspeaker systems provided with a baffle or enclosure. Also applies to systems intended to be assembled by the user (so-called 'loudspeaker kits') provided that the instructions... | |
| Applies to magnetic video recording and/or reproducing using 25.4 mm (1 in) tape on type B helical-scan recorders suitable for broadcast applications. Defines the electrical and mechanical characteristics of equipment... | |
| Applies to pressboard and presspaper for electrical purposes. The series does not apply to laminated material. This part specifies the test methods to be used in testing pressboard and presspaper... | |
| Applies to quality control and acceptance testing of oils. Two methods of analysis are given: infra-red spectrophotometry and adsorption chromatography. The contents of the corrigendum of July 1978 have been... | |
| Applies to radio transmitting and receiving equipment and systems used in the mobile services. Is restricted to land and mobile stations in the mobile services and to portable and personal... | |
| Applies to string insulator units of the can and pin type and also of the long rod type as well as to the fittings used with such insulators. Defines dimensions... | |
| Applies to tape spools used with video recorders for broadcast purposes. Standardizes the spools used in the various broadcast video recording formats. | |
| Applies to terminology for high-voltage direct current (HVDC) systems and especially to HVDC converter substations where electronic converters are used for the conversion from a.c. to d.c. or vice versa. | |
| Applies to the basic safety and essential performance of ultrasonic diagnostic equipment. The approach and philosophy used in drafting this particular standard for safety of ultrasonic diagnostic equipment are consistent... | |
| Applies to the classification of degrees of protection provided by enclosures for electrical equipment with a rated voltage not exceeding 72,5 kV. Has the status of a basic safety publication... | |
| Applies to the determination of whether or not ionizable soluble organic and inorganic materials are present by measuring the increase in volume conductivity of a liquid extract. The contents of... | |
| Applies to the safety and essential performance of laser equipment for either surgical, therapeutic, medical diagnostic, cosmetic, or veterinary applications, intended for its use on humans or animals, classified as... | |
| Classification. Class index system. Permissible errors for each class. Conditions for testing. Conditions for use. Methods of testing. Markings. Information to be supplied by the manufacturer. | |
| Complementary document to IEC 60510-1. Describes D.C. sources and the methods of measurement of their characteristics. | |
| Comprises maximum lamp outlines for tungsten filament lamps for domestic and similar general lighting purposes. | |
| Concerns the re-use of sulfur hexafluoride (SF6) after removal from electrical equipment (for maintenance, or at the end of life). This standard recommends procedures for reclaiming used SF... | |
| Considers the corrosive and erosive industrial environment to which land-based and offshore industrial-process measurement and control systems or parts of systems may be exposed during operation, during periods when they... | |
| Considers the specific operating conditions of vibration, shock, seismic and mechanical stress conditions to which land-based and offshore industrial-process measurement and control systems or parts of systems may be exposed... | |
| Consists of requirements common to both induction and conduction heating installations and induction melting installations, and specific requirements for induction and conduction heating installations, and specific requirements for induction melting... | |
| Contains requirements for capacitor kraft paper: Type 2.1: Kraft capacitor paper, Type 2.2: Kraft capacitor paper, high reliability, Type 2.3: Kraft capacitor paper low loss, Type 2.4: Kraft capacitor paper,... | |
| Contains requirements for general purpose electrical paper as described in Table I of IEC Publication 60554-1. | |
| Contains the requirements for electrolytic capacitor paper of the following types: -absorbent separator paper, long fibres; -short fibres; -non-absorbent paper. | |
| Contains the requirements for special papers which may be used for cables, transformers and conductor wrapping. | |
| Contains the requirements relating to the physical, chemical and electrical properties of two types of askarel for capacitors and four types of askarel for transformers. | |
| Covers 'precision autotransformers', 'decade transformer dividers', 'inductive dividers', 'ratio transformers', etc. Classification, limits of intrinsic error, conditions for the determination of intrinsic errors, permissible variations, additional electrical and mechanical requirements,... | |
| Covers a range of connectors with 2.54 mm (0.1 in) contact spacing intended to connect a single or double-sided printed board to another printed board or wires. Two kinds are... | |
| Covers a range of connectors with 2.54 mm (0.1 in) spacing intended to connect a double-sided printed board to another printed board or wires. Two kinds of connector are available:... | |
| Covers a range of two-part connectors with contact arrangements having spacings of 2,54 mm (0,1 in) in both directions. | |
| Covers concentric connectors for use in LF (low-frequency) audio applications such as the interconnection of headphones and microphones in sound system components. Specifies the dimensions, general requirements and tests for... | |
| Covers dimensions, general requirements and tests for a range of sockets designed for use with integrated circuits in dual-in-line format. Sockets include standard type and low-profile type. | |
| Covers specifications and test methods for unused mineral insulating oils, as delivered, intended for use in cables with oil ducts. These include hollow core cables, pipe type cables and any... | |
| Covers the definitions, the conditions and the methods of measurement used to ascertain the performance of transmitters having audio-frequency bandwidths generally not exceeding 10 kHz for the transmission of voice... | |
| Covers the dimensional and constructional characteristics for toroidal cores wound from strips of magnetically soft steel or alloy having thickness between 0.003 mm and 0.35 mm. Includes standard ranges of... | |
| Covers the methods of measurement to be used in order to evaluate the noise temperature and the noise figure of sub-systems, and/or combinations of sub-systems, under linear conditions where appropriate... | |
| Covers vulcanized fibre sheets, flat or corrugated sheets, round rods and round tubes suitable as electrical insulation. Materials made by combining with an adhesive several thicknesses of vulcanized fibre are... | |
| Deals with baseband measurements on simulated radio-relay systems which are not directly related to a particular type of signal actually being transmitted. These measurements are carried out typically at the... | |
| Deals with baseband-to-baseband measurements of the noise performance of simulated radio-relay systems used for frequency division multiplex telephony. These measurements are additional to those already given in Part 3, Section... | |
| Deals with basic measurements which are equally applicable to a sub-system such as an amplifier, or to a combination of sub-systems assembled to simulate a satellite earth station. Methods of... | |
| Deals with essential dimensions to ensure mechanical interchangeability recommended dimensions, wiring connections to contacts of plug and socket, and marking of contacts of plug and socket. The contents of the... | |
| Deals with measurements for monochrome and colour television transmission over simulated radio-relay systems. The measurements are additional to those already given in Part 3, Section Two of this publication. | |
| Deals with measurements for sub-systems used for stand-by channel switching. Gives methods of measurement for the transmission characteristics of sub-systems inserted in the transmission chain. | |
| Deals with measurements normally made at radio frequencies for transmitting and receiving equipment used in earth stations for communication through orbiting satellites. | |
| Deals with measurements on diversity equipment used for making two or more receivers at a radio-relay station suitable for diversity reception. Diversity equipment is assumed to comprise the circuit for... | |
| Deals with methods of measurement for monochrome and colour television transmission which are additional to the measurements in the baseband in IEC 60510-1-4, and which are common to telephony and... | |
| Deals with methods of measurement for sound-programme analogue channels carried by radio-relay systems. Concerned only with the audio-frequency band and is additional to the measurement described in sections three, four... | |
| Deals with safety of electroheat installations with electron guns and applies to all electroheat applications with electron guns. May also be used for non-thermal applications with electron guns and equipment... | |
| Deals with the definitions, the conditions and the methods of measurement used to ascertain the performance of receivers having audio-frequency bandwidths generally not exceeding 10 kHz for the reception of... | |
| Deals with the measurements of interference on simulated radio-relay systems for television and f.d.m. telephony transmission. Measurements carried out both with and without the interfering source present in order to... | |
| Defines a standard test method for detecting contact disturbance of electromechanical components under specified dynamic conditions. | |
| Defines a standard test method for measuring the resistance between component housings (shells) which are intended to provide electrical continuity when mated. | |
| Defines a standard test method for measuring the shielding effectiveness of a connector, or a connector fitted with an accessory and terminated with a cable. The complete assembly has a... | |
| Defines a standard test method for the examination of dimension and mass of electromechanical components (essentially connectors). The measurements are made on the actual parts with the aid of suitable... | |
| Defines a standard test method for the visual examination of electromechanical components (essentially connectors). The visual examination checks the identification, appearance, workmanship and finish of an item against the relevant... | |
| Defines a standard test method to assess the ability of a component to function in a specified manner, in a specified environment which might be encountered during normal use, including... | |
| Defines a standard test method to assess the ability of a connector to withstand driving fine sand and dust. | |
| Defines a standard test method to assess the ability of an electromechanical component (essentially a connector) to be used under specified voltage conditions without showing partial discharges. | |
| Defines a standard test method to assess the ability of components (essentially connectors) to be stored and/or to function in a specified manner under conditions of high relative humidity. | |
| Defines a standard test method to assess the ability of components (essentially connectors) to be stored and/or to function in a specified manner under specified conditions of cold. | |
| Defines a standard test method to assess the ability of components (essentially connectors) to be stored and/or to function in a specified manner under specified conditions of dry heat. | |
| Defines a standard test method to assess the ability of components (essentially connectors) to be stored and/or to function in a specified manner under specified conditions of low air pressure,... | |
| Defines a standard test method to assess the ability of components (essentially connectors) to be stored and/or to function under conditions of high relative humidity and to observe the effects... | |
| Defines a standard test method to assess the ability of components (essentially connectors) to function in a specified manner, during and after subjection to the conditions which prevail in an... | |
| Defines a standard test method to assess the ability of components (essentially connectors) to withstand rapid change of temperature in air such as might occur during storage, transportation and use. | |
| Defines a standard test method to assess the ability of components (essentially connectors) to withstand specified severities of acceleration. | |
| Defines a standard test method to assess the ability of components (essentially connectors) to withstand specified severities of bump. | |
| Defines a standard test method to assess the ability of components (essentially connectors) to withstand specified severities of shock. | |
| Defines a standard test method to assess the ability of components (essentially connectors) to withstand specified severities of sinusoidal vibration. | |
| Defines a standard test method to assess the ability of the terminations of a connector to remain covered with solder when being brought into contact with molten solder under specified... | |
| Defines a standard test method to assess the effects of a controlled atmosphere polluted by gases at very low concentration on electrical contacts or connections. | |
| Defines a standard test method to assess the effects of accidental exposure to fluids and lubricants on electrical connecting devices. | |
| Defines a standard test method to assess the effects of impacting water or specified fluid on electrical connecting devices. | |
| Defines a standard test method to assess the extent and the effect of a controlled salt-laden atmosphere on the finish of a specimen (essentially a connector). | |
| Defines a standard test method to assess the extent and the effect of mould growth on the functioning of a component (essentially a connector) submitted to a mould culture. | |
| Defines a standard test method to assess the insulation resistance of electromechanical components (essentially connectors). | |
| Defines a standard test method to assess the solderability of the terminations of a component designed for use with printed boards or for other applications using similar soldering techniques. | |
| Defines a standard test method to determine the ability of a component to withstand specified test voltages applied in a specified manner. | |
| Defines a standard test method to determine the variation of contact resistance of electromechanical components (essentially connectors) under specified dynamic conditions. | |
| Defines a standard test method to measure the electrical engagement length in a connector. | |
| Defines a standard test method to measure the electrical resistance across a pair of mated contacts or a contact with a measuring gauge. Measurements may be carried out with direct... | |
| Defines a standard test method to measure the electrical resistance across a pair of mated contacts or a contact with a measuring gauge. | |
| Defines a standard test method to verify that gas-tight areas have been formed between wrapped wire and the post of a wrapped connection. | |
| Defines a standard test method to verify the ability of a connector to prevent the accidental touching of its contact by the front of the mating connector. The contents of... | |
| Defines a test method intended to assess the ability of components to withstand specified severities of random vibration. | |
| Defines a test method intended to assess the screening effectiveness of screened non-circular multi-pole, electrically short, connectors by the measurement of the effective (surface) transfer impedance, using a network analyzer,... | |
| Defines and describes the measurements normally made on high-power amplifiers used in satellite earth station transmitters. | |
| Defines certain terms used in this series of publications. Lays down the standard test conditions for the power supply and the environment, and also some conditions deviating from standard test... | |
| defines equipment, methods, and procedures for obtaining laboratory measurements of sound pressure levels radiated by control valves and/or associated piping configurations, including fixed restrictions, through which compressible fluids are passing. | |
| Defines measurement methods for assessing the electrical characteristics of sub-systems in order to facilitate the comparison of results of measurements made by different observers. The methods described are intended for... | |
| Defines principal electromechanical characteristics and test methods enabling the performance of flexible waveguide assemblies to be verified. Contains terminology specific to flexible waveguide assemblies and specifies IEC type designation. | |
| Defines standard test method to check the ability of connectors to withstand the use of standardised tooling for insertion and extraction of contacts. | |
| Defines the concept of permanent filtration in X-ray tube assemblies for medical diagnosis and radiotherapy and describes a method for its determination. It contains requirements for statements of compliance for... | |
| Defines the electrical and mechanical characteristics of equipment which will provide for interchangeability of recording. The requirements given are related to 525 line-60 field and/or for 625 line-50 field systems. | |
| Defines the timing relationships between the various recorded signals and specifies the time-code record flux level. Corrects Figure 5A. | |
| Defines two test methods for evaluating the performance of a connector in a transmission line by measuring the reflections produced by it in the time domain. The connector is treated... | |
| Definitions; classification; limits of intrinsic errors: permissible variations; further requirements; markings; symbols. | |
| Describes a frequency and a time domain method to measure attenuation/insertio n loss as a function of frequency. Is applicable to electrical connectors, sockets, cable assemblies or interconnection systems. | |
| Describes a method for measuring the effect a specimen has on the rise time of a signal passing through it. | |
| Describes a method for measuring the time it takes for a digital signal to propagate from one specified point to a second specified point. | |
| Describes a standard test method to assess the ability of a connector to withstand specified flame and vibration during a 20 min exposure by providing specified electrical performance for the... | |
| Describes characteristics and tests methods for gas-filled radiation detectors used for the protection of nuclear reactors. Applies to the radiation detectors which are installed external to the core of nuclear... | |
| Describes methods for measuring an eye pattern response and jitter in the time domain. | |
| Describes methods for the detection of ionizing radiation and for the direct and indirect measurement of field pattern and exposure rate of random incidental radiation emanating from high-voltage electronic tubes. | |
| Describes methods of measurement of the electrical characteristics of the low-noise amplifier which follows an earth station antenna. | |
| Describes methods of measurement of the electrical characteristics of up-converters and down-converters used in satellite earth station transmitters and receivers. | |
| Describes selected methods of measurement applicable to the electrical characteristics of terrestrial radio-relay receivers, excluding r.f. branching and switching networks. | |
| Describes selected methods of measurement applicable to the electrical characteristics of terrestrial radio-relay transmitters of the heterodyne type excluding r.f. branching and switching networks. | |
| Describes test methods to measure impedance, reflection coefficient, and voltage standing wave ratio in the time and frequency domains. Applies to interconnect assemblies, such as electrical connectors and cable assemblies,... | |
| Describes test procedures for measuring the magnitude of the electric and magnetic coupling between driven and quiet lines of an interconnect assembly. Both time domain and frequency domain methods for... | |
| Describes the electrical applications of askarels, the benefits and risks arising from their use as well as various aspects related to safety, disposal, packaging and labelling. | |
| Describes the test methods which are to be employed to test properties of used and unused askarels. | |
| Describes two procedures each using different apparatus to measure the tendency of insulating liquids to evolve or absorb gas when subjected to electrical stress. The contents of the corrigendum of... | |
| Detail a standard test method to assess the effectiveness of the interfacial sealing of a connector against ingress of water by exposure to low pressure whilst immersed in a salt... | |
| Details a standard method to assess the mechanical strength of solderless connections including integrated strain relief features. | |
| Details a standard method to determine the ability of pre-insulated crimp barrels to withstand the crimp operation without damage to the insulation. | |
| Details a standard test method to assess the ability of a component (essentially a connector) to carry its specified current, at room temperature, without exceeding a specified temperature rise. | |
| Details a standard test method to assess the ability of a connector to withstand the heating stresses produced by a mass soldering operation. | |
| Details a standard test method to assess the ability of a connector to withstand the heating stresses produced by a soldering iron. | |
| Details a standard test method to assess the capability of polarizing and or keying of connectors to allow intended mating and prevent unintended mating. | |
| Details a standard test method to assess the current-carrying capacity of electromechanical components (essentially connectors) at elevated ambient temperature. | |
| Details a standard test method to assess the effectiveness of seals against gas pressure differentials. | |
| Details a standard test method to assess the effectiveness of the sealing of a connector against ingress of water by exposure to low pressure whilst immersed in a salt solution. | |
| Details a standard test method to assess the effectiveness of the sealing of a connector against ingress of water under specified conditions of pressure and time. | |
| Details a standard test method to assess the solderability of the terminations of a connector designed for use with printed boards or for other applications using similar soldering techniques. | |
| Details a standard test method to assess the solderability of the terminations of a connector that are designed to be soldered with a soldering iron and the soldering bath test... | |
| Details a standard test method to measure the force to fully engage or separate mating connectors, including the effect of any locking, latching, sealing, engaging, separating or similar device, that... | |
| Details a standard test method to measure the insertion and withdrawal forces of mating connectors, or of a connector with the mating insertion and/or withdrawal gauge(s) specified in the connector... | |
| Details a standard test method to verify the effectiveness of the sealing of a component against flux and cleaning solvents during the machine soldering process. | |
| Details specific requirements for luminaires for use with tungsten filament, fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V for use in clinical areas in which... | |
| Draws up a standard method to assess the performance of mated contact pairs of connectors with an electrical overload current flowing through them for a limited period of time between... | |
| Establishes a common vocabulary for terms and definitions for determining the functions and characteristics of brush-holders. Covers arrangements of brushes and boxes, pressure systems and characteristics of construction. Contains illustrations... | |
| Establishes mandatory requirements and gives a list of characteristics of equipment for grading and sorting radioactive ores in containers at minehead and in opencast workings. | |
| Establishes recommended values for characteristic input and output quantities of single sideband power line carrier terminals and the definitions essential for an understanding of the requirements. | |
| Establishes suitable procedures for commissioning, operating and maintaining hydraulic turbines and associated equipment. Applies to impulse and reaction turbines of all types, and especially to large turbines directly coupled to... | |
| Establishes uniform conditions for assessing the mechanical and climatic properties of ceramic resonators, describes test methods, gives recommendations for standard values and gives guidance for the use of such resonators. | |
| Gives certain definitions and some general observations on simulated systems. | |
| Gives definitions and general requirements, including a designation system and lists of thicknesses. The contents of the corrigendum of March 1979 have been included in this copy. | |
| Gives definitions and methods of measurement applicable to combinations of sub-systems, for the purpose of assessing the overall performance of a satellite earth station. | |
| Gives definitions, classification, forms and colours, general and geometric requirements. | |
| Gives general conditions of measurements and requirements for interconnection, safety and published data. | |
| Gives general information on the application of test methods on the IEC 60512 series. Is to be used in conjunction with any parts of the IEC 60512 series. | |
| Gives methods for measuring the figure of merit (G/T) of earth station receiving systems using calibrated radio stars. Characteristics of the principal radio stars are specified in the appendix. | |
| Gives methods of measurement for the electrical characteristics of frequency demodulations. Where possible the measurements are limited to the basic demodulator excluding the de-emphasis network and the networks associated with... | |
| Gives methods of measurement for the electrical characteristics of frequency modulators, using where possible only measurement involving the basic modulator. | |
| Gives methods of measurement for the linear and non-linear characteristics of r.f. branching networks for radio-relay receivers and transmitters. | |
| Gives procedures for determining the electrical volume resistivity and mass resistivity of solid (non-stranded) metallic conductor and resistor materials, and the resistance per unit length of solid conductors (of uniform... | |
| Gives standard conditions of measurement and methods of measuring the characteristics common to sub-systems of terrestrial line-of-sight radio-relay systems and to simulated radio-relay systems using frequency modulation. The tests described... | |
| Gives standard outlines of piezoelectric ceramic resonators. | |
| Gives the definitions, the conditions and the methods of measurement used to ascertain the performance of transmitters and to make possible a meaningful comparison of the results of measurements made... | |
| Gives the limiting values for power received by land-based and offshore industrial-process measurement and control systems or parts of systems during operation. Maintenance and repair conditions are not considered. | |
| Gives the overall lengths of following types: segmental ball, eccentric rotary plug, and barstock globe; wafer butterfly valves are excluded. | |
| Gives the requirements for ambient curing finishing varnishes. | |
| IEC 60464-2:2001+A1:2006 Specifies methods of test to be used for testing varnishes used for electrical insulation. This includes methods of test to be applied before and others to be applied... | |
| IEC 60464-3-1:2001+A1:20 06 Gives the requirements for ambient curing finishing varnishes. This consolidated version consists of the second edition (2001) and its amendment 1 (2006). Therefore, no need to order... | |
| IEC 60464-3-2:2001+A1:20 06 This sheet specifies requirements for hot curing impregnating varnishes and includes requirements for certain properties at elevated temperatures. This consolidated version consists of the second edition (2001)... | |
| IEC 60469:2013 provides definitions of terms pertaining to transitions, pulses, and related waveforms and provides definitions and descriptions of techniques and procedures for measuring their parameters. The waveforms considered in... | |
| IEC 60475:2011 is applicable to the procedure to be used for insulating liquids in delivery containers and in electrical equipment such as power and instrument transformers, reactors, bushings, oil-filled cables,... | |
| IEC 60479-1:2018(E) provides basic guidance on the effects of shock current on human beings and livestock. This basic safety publication is primarily intended for use by technical committees in the... | |
| IEC 60493-1:2011 gives statistical methods which may be applied to the analysis and evaluation of the results of ageing tests. It covers numerical methods based on mean values of normally... | |
| IEC 60494-1:2013 specifies the general assembly characteristics which are to be applied to pantographs, to enable current collection from the overhead contact line system. It also specifies the tests the... | |
| IEC 60494-2:2013 defines the general assembly characteristics which are to be applied to pantographs, to enable current collection from the overhead line equipment. It also defines the tests the pantographs... | |
| IEC 60500:2017 specifies the relevant characteristics and properties of hydrophones in the frequency range 1 Hz to 500 kHz, and specifies how to report these characteristics. Provides guidance on the... | |
| IEC 60502-1:2004+A1:2009 specifies the construction, dimensions and test requirements of power cables with extruded solid insulation for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV... | |
| IEC 60502-2:2014 is available as IEC 60502-2:2014 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC... | |
| IEC 60502-2:2014 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60502-4:2010 specifies the test requirements for type testing of accessories for power cables with rated voltages from 3,6/6 (7,2) kV up to 18/30 (36) kV, complying with IEC 60502-2. | |
| IEC 60505:2011 establishes the basis for estimating the ageing of electrical insulation systems (EIS) under conditions of either electrical, thermal, mechanical, environmental stresses or combinations of these (multifactor stresses). It... | |
| IEC 60507:2013 is applicable for the determination of the power frequency withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on a.c. systems... | |
| IEC 60512-1-100:2012 provides a listing of the 60512 series of standards for specific tests that are created for connectors. Further it gives cross-references with the former (60)512 standards, where different... | |
| IEC 60512-1-101:2015 This blank detail (tests and measurements) specification is a supplementary document to the IEC 60512 test and measurements specification series and contains requirements for style, layout and content... | |
| IEC 60512-11-14:2003 defines a standard test method to assess the effects of controlled corrosion in industrial atmospheres, in a specified concentration of polluted gas(es). Is applicable for the testing of... | |
| IEC 60512-15-1:2008 details a standard test method to assess the effectiveness of the contact retaining system to withstand axial loads likely to be encountered during normal use. The contact retaining... | |
| IEC 60512-15-2:2018 This part of IEC 60512, when required by the detail (product) specification, is used for testing connectors within the scope of technical committee 48. It may also be... | |
| IEC 60512-15-3:2008 details a standard test method to assess the effectiveness of the insert retaining system to withstand torsional stresses likely to be encountered during normal use. | |
| IEC 60512-15-4:2008 details a standard test method to determine the forces required to insert contact into, and extract them from, their normal position in the intended connector. | |
| IEC 60512-15-5:2008 details a standard test method to verify the capability of the contact retention system to withstand dynamic mechanical loading of the contacts that tends to dislodge them. | |
| IEC 60512-15-6:2008 details a standard test method to assess the effectiveness of the coupling device to maintain engagement of mated connectors fitted with coupling and / or retaining devices when... | |
| IEC 60512-15-7:2008 details a standard test method to assess the ability of a connector cover and its attachment to withstand mechanical stresses. | |
| IEC 60512-16-11:2008 details a standard test method to determine ability of a component to resist forces that might strip a wrapped connection from its post along the axis of the... | |
| IEC 60512-16-13:2008 details a standard test method to determine if a wrapped connection has been made without damaging the wrapping wire. Such wrapped connections are described in IEC 60352-1. | |
| IEC 60512-16-14:2008 details a standard test method to determine the ability of a fixed male tab and its fixing to withstand a specified bending stress. If so specified in the... | |
| IEC 60512-16-16:2008 details a standard test method to determine the ability of a fixed male tab and its fixing to withstand a specified torque. If so specified in the detail... | |
| IEC 60512-16-17:2008 details a standard test method to determine the ability of a fixed male tab and its fixing to withstand specified tensile and compressive forces. If so specified in... | |
| IEC 60512-16-18:2008 details a standard test method to measure the deflection of a simulated contact in its cavity or housing. Although this test method is intended for cylindrical male contacts,... | |
| IEC 60512-16-1:2008 details a standard test method to assess the effectiveness of the elastic system of contacts to resist damage from the insertion of a specified test probe. | |
| IEC 60512-16-21:2012 The object of this standard is to define a standard test method to assess the possibility of whisker growth by external mechanical stress on the tin and tin-alloy... | |
| IEC 60512-16-2:2008 details a standard test method to assess the effectiveness of the means by which an oversize male contact, or other similar object, is prevented from entering the equivalent... | |
| IEC 60512-16-3:2008 details a standard test method to determine the ability of a contact to withstand a specified bending moment or force. If so specified in the detail specification, forces... | |
| IEC 60512-16-4:2008 details a standard test method to determine the tensile strength of a crimped connection. | |
| IEC 60512-16-5:2008 details a standard test method to determine the holding capacity of contacts with resilient features by means of gauges. | |
| IEC 60512-16-6:2008 details a standard test method to assess the ability of terminations to withstand the mechanical stresses likely to be applied during normal assembly operations. | |
| IEC 60512-16-7:2008 details a standard test method to assess the effectiveness of contacts to resist deformation (damage) from crimping operations. | |
| IEC 60512-16-8:2008 details a standard test method to assess the effectiveness of an insulation grip to hold the insulation of a cable/wire under specified conditions. | |
| IEC 60512-16-9:2008 details a standard test method to determine the holding capacity of grounding contact springs by means of gauges. | |
| IEC 60512-17-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-17-2:2011 when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when... | |
| IEC 60512-17-3:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-17-4:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-19-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-1:2018 is available as IEC 60512-1:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC... | |
| IEC 60512-1:2018 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides... | |
| IEC 60512-20-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-20-3:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-21-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-22-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-23-2:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-23-3:2018 is available as IEC 60512-23-3:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC... | |
| IEC 60512-23-3:2018 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides... | |
| IEC 60512-24-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-25-9:2008 defines a test method which is intended to assess the near-end alien crosstalk and the far-end alien crosstalk between connectors in close proximity, when mounted in their mounting... | |
| IEC 60512-26-100:2008 specifies the test and measurements and the related measurement setup and reference arrangements for interoperability and backward compatibility tests for the development and qualification of 8-way, free and... | |
| IEC 60512-26-100:2008+A1 :2011 specifies the test and measurements and the related measurement setup and reference arrangements for interoperability and backward compatibility tests for the development and qualification of 8-way, free... | |
| IEC 60512-27-100:2011 specifies the test methods for transmission performance for IEC 60603-7 series connectors up to 500 MHz. It is also suitable for testing lower frequency connectors if they meet... | |
| IEC 60512-28-100:2013 specifies the test methods for transmission performance for IEC 60603-7 and IEC 61076-3 series connectors up to 1 000 MHz. It is also suitable for testing lower frequency... | |
| IEC 60512-29-100:2015 specifies the test methods for transmission performance for M12-style connectors up to 500 MHz. It is also suitable for testing lower frequency connectors if they meet the requirements... | |
| IEC 60512-7-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-7-2:2011 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-8-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-8-2:2011 when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when... | |
| IEC 60512-8-3:2018 this part of IEC 60512, when required by the detail (product) specification, is used for testing connectors within the scope of IEC technical committee 48. It may also... | |
| IEC 60512-9-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-9-2:2011 when required by the detail specification, this part of IEC 60512, is used for testing connectors within the scope of technical committee 48. It may also be used... | |
| IEC 60512-9-3:2011 defines a standard test method to assess the mechanical and electrical operational endurance, i.e. engaging and separating cycles, of a connector in an operating mode which includes a... | |
| IEC 60512-9-4:2011 when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when... | |
| IEC 60512-9-5:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified... | |
| IEC 60512-99-001:2012 used for the assessment of connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO/IEC 11801 Class... | |
| IEC 60519-10:2013 provides safety requirements for electrical resistance trace heating systems used in industrial and commercial applications for piping, vessels, roofs, concrete slab heating and other similar applications. This second... | |
| IEC 60519-12:2016 specifies safety requirements for industrial electroheating equipment and installations in which infrared radiation – usually generated by infrared emitters – is significantly dominating over heat convection or heat... | |
| IEC 60519-1:2015 specifies general safety requirements for industrial installations or equipment intended for electroheating (EH) and electroheating based treatment technologies as well as for electromagnetic processing of materials (EPM). This... | |
| IEC 60519-21:2008 is applicable to indirect resistance heating equipment for the heating and melting of glass, operating in voltage bands 1 and 2. These particular requirements also apply to equipment... | |
| IEC 60519-4:2013 provides particular safety requirements for electric arc furnace installations and its operating and maintenance personnel. These safety provisions concern the protection of persons and the environment against dangers... | |
| IEC 60519-6:2011 is applicable to equipment using microwave energy alone or in combination with other kinds of energy for industrial heating of materials. This part is applicable to industrial microwave... | |
| IEC 60529:1989 Applies to the classification of degrees of protection provided by enclosures for electrical equipment with a rated voltage not exceeding 72,5 kV. It has the status of a... | |
| IEC 60529:1989+A1:1999+A 2:2013 Applies to the classification of degrees of protection provided by enclosures for electrical equipment with a rated voltage not exceeding 72,5 kV. Has the status of a... | |
| IEC 60532:2010 applies to installed dose rate meters, warning assemblies and monitors that are used to prevent or mitigate a minor radioactive release, or minor degradation of fuel, within the... | |
| IEC 60533:2015 is available as IEC 60533:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC... | |
| IEC 60533:2015 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60534-2-1:2011 includes equations for predicting the flow of compressible and incompressible fluids through control valves. The equations for incompressible flow are based on standard hydrodynamic equations for Newtonian incompressible... | |
| IEC 60534-2-3:2015(E) is applicable to industrial-process control valves and provides the flow capacity test procedures for determining the following variables used in the equations given in IEC 60534-2-1: a) flow... | |
| IEC 60534-2-4:2009 applies to all types of industrial-process control valves. It defines how to state typical control valve inherent flow characteristics and inherent rangeabilities. It also defines how to establish... | |
| IEC 60534-7:2010 provides a list of requirements that are necessary for the procurement of the majority of control valves for process systems. The list is arranged to assist the specification... | |
| IEC 60534-8-2:2011 includes the method for measuring the sound pressure level due to liquid flow through a control valve and the method for determining the characteristic increase of noise due... | |
| IEC 60534-8-3:2010 establishes a theoretical method to predict the external sound-pressure level generated in a control valve and within adjacent pipe expanders by the flow of compressible fluids. This method... | |
| IEC 60534-8-4:2015 establishes a method to predict the noise generated in a control valve by liquid flow and the resulting noise level measured downstream of the valve and outside of... | |
| IEC 60539-1:2016 is applicable to directly heated negative temperature coefficient thermistors, typically made from transition metal oxide materials with semiconducting properties. It establishes standard terms, inspection procedures and methods of... | |
| IEC 60539-2:2003 is applicable to surface mount directly heated negative temperature coefficient thermistors, typically made from transition metal oxide materials with semiconducting properties. These thermistors have metallized connecting pads or... | |
| IEC 60539-2:2003+A1:2010 is applicable to surface mount directly heated negative temperature coefficient thermistors, typically made from transition metal oxide materials with semiconducting properties. These thermistors have metallized connecting pads or... | |
| IEC 60544-1:2013 deals broadly with the aspects to be considered in evaluating the effects of ionizing radiation on all types of organic insulating materials. It also provides, for X-rays, gamma-rays,... | |
| IEC 60544-2:2012 specifies the controls maintained over the exposure conditions during and after the irradiation of insulating materials with ionizing radiation prior to the determination of radiation-induced changes in physical... | |
| IEC 60544-5:2011 covers ageing assessment methods which can be applied to components based on polymeric materials (e.g. cable insulation and jackets, elastomeric seals, polymeric coatings, gaiters) which are used in... | |
| IEC 60546-1:2010 is intended to specify uniform methods of test for evaluating the performance of industrial-process PID controllers with analogue input and output signals. The test conditions specified in this... | |
| IEC 60546-2:2010 applies to pneumatic and electrical industrial-process controllers using analogue signals which are in accordance with IEC 60381-1 and IEC 60381-2. The provisions of this standard are applicable in... | |
| IEC 60549:2013 applies to external fuses used with high-voltage capacitors according to IEC 60871-1, Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part... | |
| IEC 60556:2006 describes methods of measuring the properties used to specify polycrystalline microwave ferrites in accordance with IEC 60392 and for general use in ferrite technology. These measuring methods are... | |
| IEC 60556:2006+A1:2016 describes methods of measuring the properties used to specify polycrystalline microwave ferrites in accordance with IEC 60392 and for general use in ferrite technology. These measuring methods are... | |
| IEC 60567:2011 deals with the techniques for sampling free gases from gas-collecting relays from power transformers. Three methods of sampling free gases are described. The techniques described take account, on... | |
| IEC 60570:2003+A1:2017 applies to track systems for ordinary interior use with two or more poles and with provision for earthing (Class 1), with a rated voltage not exceeding 440 V... | |
| IEC 60571:2012 covers the conditions of operation, design, construction, and testing of electronic equipment, as well as basic hardware and software requirements considered necessary for competent, reliable equipment. Applies to... | |
| IEC 60584-1:2013 specifies reference functions and tolerances for letter-designated thermocouples (Types R, S, B, J, T, E, K, N, C and A). Temperatures are expressed in degrees Celsius based on... | |
| IEC 60587:2007 describes two test methods for the evaluation of electrical insulating materials for use under severe ambient conditions at power frequencies (45 Hz to 65 Hz) by measurement of... | |
| IEC 60598-1:2014 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover:... | |
| IEC 60598-1:2014+A1:2017 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover:... | |
| IEC 60598-2-11:2013 specifies requirements for household aquarium luminaires incorporating electric light sources on supply voltages not exceeding 1 000 V. This second edition cancels and replaces the first edition published... | |
| IEC 60598-2-12:2013 specifies requirements for mains socket-outlet mounted nightlights for use with electric light sources, on supply voltages not exceeding 250 V a.c. 50/60 Hz. This second edition cancels and... | |
| IEC 60598-2-13:2006+A1:2 011 specifies requirements for ground recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V, for indoor or outdoor use, e.g. in... | |
| IEC 60598-2-13:2006+A1:2 011+A2:2016 specifies requirements for ground recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V, for indoor or outdoor use, e.g. in... | |
| IEC 60598-2-14:2009 applies to luminaires for cold cathode tubular discharge lamps and similar equipment, operating on a no-load rated output voltage over 1 000 V but not exceeding 10 000... | |
| IEC 60598-2-17:2017 specifies requirements for stage, television, film and photographic studio luminaires (including spot and floodlighting projectors) for use outdoors and indoors, with electric light sources on supply voltages not... | |
| IEC 60598-2-20:2014 specifies requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding... | |
| IEC 60598-2-21:2014 specifies requirements for rope lights (sealed lighting chains) fitted with non-replaceable series- or parallel- or a combination of series/parallel-conn ected light sources for use either indoors or outdoors... | |
| IEC 60598-2-22:2014 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V. This fourth edition cancels and replaces the third edition... | |
| IEC 60598-2-22:2014+A1:2 017 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V. This fourth edition cancels and replaces the third... | |
| IEC 60598-2-24:2013 series specifies requirements for luminaires intended for use where the necessity of limited temperature on the outer surface exists, due to the risk of thermal effects, combustion or... | |
| IEC 60598-2-2:2011 specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V. This section does not apply to air-handling or liquid-cooled... | |
| IEC 60598-2-3:2002+A1:20 11 specifies requirements for: - luminaires for road, street lighting and other public outdoor lighting applications; - tunnel lighting; - column-integrated luminaires with a minimum total height above... | |
| IEC 60598-2-4:2017 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60598-2-5:2015 specifies requirements for floodlights for use with electrical light sources on supply voltages not exceeding 1 000 V. This third edition cancels and replaces the second edition published... | |
| IEC 60598-2-8:2013 specifies requirements for handlamps and similar portable luminaires which are held in the hand, hooked up or resting on a surface for use with electric light sources on... | |
| IEC 60599:2015 is available as IEC 60599:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC... | |
| IEC 60599:2015 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60601-1-10:2007+A1:2 013 Specifies requirements for the development (analysis, design, verification and validation) of a physiologic closed-loop controller (PCLC) as part of a physiologic closed-loop control system (PCLCS) in medical... | |
| IEC 60601-1-11:2015 applies to the basic safety and essential performance of medical electrical equipment and medical electrical systems for use in the home healthcare environment. It applies regardless of whether... | |
| IEC 60601-1-11:2015 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60601-1-12:2014 constitutes a collateral standard to IEC 60601-1: Medical electrical equipment - Part 1: General requirements for basic safety and essential performance hereafter referred to as the general standard. | |
| IEC 60601-1-2:2014 applies to the basic safety and essential performance of Medical Equipment (ME) equipment and ME systems in the presence of electromagnetic disturbances and to electromagnetic disturbances emitted by... | |
| IEC 60601-1-3:2008+A1:20 13 applies to X-ray equipment and to subassemblies of such equipment, where radiological images of a human patient are used for diagnosis, planning or guidance of medical procedures. | |
| IEC 60601-1-6:2010 specifies a process for a manufacturer to analyse, specify, design, verify and validate usability, as it relates to basic safety and essential performance of medical electrical equipment. This... | |
| IEC 60601-1-6:2010+A1:20 13 specifies a process for a manufacturer toanalyse, specify, design, verify and validate usability, as it relates to basic safety and essential performance of medical electrical equipment. This... | |
| IEC 60601-1-8:2006+A1:20 12 Specifies basic safety and essential performance requirements and tests for alarm systems in medical electrical equipment and medical electrical systems and to provide guidance for their application. | |
| IEC 60601-1-9:2007 The objective of this collateral standard is to improve the environmental impact for the entire range of medical electrical equipment, taking into account all stages of the product... | |
| IEC 60601-1-9:2007+A1:20 13 The objective of this collateral standard is to improve the environmental impact for the entire range of medical electrical equipment, taking into account all stages of the... | |
| IEC 60601-1:2005 contains requirements concerning basic safety and essential performance that are generally applicable to medical electrical equipment. For certain types of medical electrical equipment, these requirements are either supplemented... | |
| IEC 60601-1:2005+A1:2012 (E) contains requirements concerning basic safety and essential performance that are generally applicable to medical electrical equipment. For certain types of medical electrical equipment, these requirements are either... | |
| IEC 60601-2-10:2012 specifies the requirements for the safety and essential performance of nerve and muscle stimulators, for use in the practice of physical medicine. This includes transcutaneous electrical nerve stimulators... | |
| IEC 60601-2-10:2012+A1:2 016 specifies the requirements for the safety and essential performance of nerve and muscle stimulators, for use in the practice of physical medicine. This includes transcutaneous electrical nerve... | |
| IEC 60601-2-11:2013 applies to the basic safety and essential performance of gamma beam therapy equipment, including multi-source stereotactic radiotherapy equipment. This particular standard of the 60601 series, establishes requirements to... | |
| IEC 60601-2-16:2018 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60601-2-17:2013 applies to the basic safety and essential performance of automatically-contro lled Brachytherapy Afterloading Medical Equipment. This standard does not specify requirements for sealed radioactive sources. This third edition... | |
| IEC 60601-2-18:2009 establishes particular basic safety and essential performance requirements for endoscopic equipment. The minimum safety requirements specified in this particular standard are considered to provide for a practical degree... | |
| IEC 60601-2-19:2009 specifies safety requirements for infant incubators. This particular standard amends and supplements IEC 60601-1:2005, Medical electrical equipment - Part 1: General requirements for basic safety and essential performance. | |
| IEC 60601-2-19:2009+A1:2 016 specifies safety requirements for infantincubators. This particular standard amends and supplements IEC 60601-1:2005, Medical electrical equipment - Part 1: General requirements for basic safety and essential performance. | |
| IEC 60601-2-1:2009 applies to the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV, used for treatment of patients. This particular standard establishes... | |
| IEC 60601-2-1:2009+A1:20 14 applies to the basic safety and essentialperformance of electron accelerators in the range 1 MeV to 50 MeV, used for treatment of patients. This particular standard establishes... | |
| IEC 60601-2-20:2009 specifies safety requirements for infant transport incubators. This particular standard amends and supplements IEC 60601-1:2005, Medical electrical equipment - Part 1: General requirements for basic safety and essential... | |
| IEC 60601-2-20:2009+A1:2 016 specifies safety requirements for infanttransport incubators. This particular standard amends and supplements IEC 60601-1:2005, Medical electrical equipment - Part 1: General requirements for basic safety and essential... | |
| IEC 60601-2-21:2009 specifies the safety requirements for infant radiant warmers. This particular standard amends and supplements IEC 60601-1:2005, Medical electrical equipment - Part 1: General requirements for basic safety and... | |
| IEC 60601-2-21:2009+A1:2 016 specifies the safety requirements for infant radiant warmers. This particular standard amends and supplements IEC 60601-1:2005, Medical electrical equipment - Part 1: General requirements for basic safety... | |
| IEC 60601-2-22:2007+A1:2 012 applies to the safety and essential performance of laser equipment for either surgical, therapeutic, medical diagnostic, cosmetic, or veterinary applications, intended for its use on humans or... | |
| IEC 60601-2-23:2011 applies to the basic safety and essential performance of transcutaneous partial pressure monitoring equipment. It applies to transcutaneous monitors used with adults, children and neonates, and it includes... | |
| IEC 60601-2-24:2012 applies to the basic safety and essential performance of infusion pumps and volumetric infusion controllers. This standard applies to administration sets insofar as their characteristics influence the basic... | |
| IEC 60601-2-25:2011 applies to the basic safety and essential performance of electrocardiographs intended by themselves or as a part of a medical electrical system, for the production of electrocardiogram reports... | |
| IEC 60601-2-26:2012 standard applies to basic safety and essential performance of electroencephalograp hs used in a clinical environment (e.g., hospital, physician's office, etc.). This standard does not cover requirements for... | |
| IEC 60601-2-27:2011 applies to electrocardiographic monitoring equipments used in a hospital environment as well as when used outside the hospital environment, such as in ambulances and air transport. This particular... | |
| IEC 60601-2-28:2017 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60601-2-29:2008 establishes requirements to be complied with by manufacturers in the design and construction of radiotherapy simulators; it does not attempt to define their optimum performance requirements. Its purpose... | |
| IEC 60601-2-2:2017 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60601-2-31:2008 applies to the basic safety and essential performance of external pacemakers powered by an internal electrical power source. The minimum safety requirements specified in this particular standard are... | |
| IEC 60601-2-31:2008+A1:2 011 consists of the second edition (2008) and its amendment 1 (2011). The technical content is therefore identical to the base edition and its amendment and has been... | |
| IEC 60601-2-33:2010 establishes particular basic safety and essential performance requirements for magnetic resonance equipment to provide protection for the patient and the magnetic resonance worker. This third edition cancels and... | |
| IEC 60601-2-33:2010+A1:2 013 establishes particular basic safety and essential performance requirements for magnetic resonance equipment to provide protection for the patient and the magnetic resonance worker. This third edition cancels... | |
| IEC 60601-2-33:2010+A1:2 013+A2:2015 establishes particular basic safety and essential performance requirements for magnetic resonance equipment to provide protection for the patient and the magnetic resonance worker. It has also been... | |
| IEC 60601-2-34:2011 concerns the basic safety and essential performance of invasive blood pressure monitoring equipment. It amends and supplements IEC 60601-1 (third edition, 2005): Medical electrical equipment - Part 1:... | |
| IEC 60601-2-36:2014 applies to basic safety and essential performance of equipment for extracorporeally induced lithotripsy including equipment for other medical applications of therapeutic extracorporeally induced focused pressure pulses. The applicability... | |
| IEC 60601-2-37:2007+A1:2 015 Applies to the basic safety and essential performance of ultrasonic diagnostic equipment. The approach and philosophy used in drafting this particular standard for safety of ultrasonic diagnostic... | |
| IEC 60601-2-39:2018 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60601-2-3:2012 specifies the requirements for the basic safety and essential performance of short-wave therapy equipment. Short-wave therapy equipment are defined as medical equipment for the therapeutic treatment of a... | |
| IEC 60601-2-3:2012+A1:20 16 specifies the requirements for the basic safety and essential performance of short-wave therapy equipment. Short-wave therapy equipment are defined as medical equipment for the therapeutic treatment of... | |
| IEC 60601-2-40:2016 applies to the basic safety and essential performance of electromyographs and evoked response equipment, hereafter referred to as ME equipment. ME equipment intended for transcutaneous electrical nerve stimulators... | |
| IEC 60601-2-41:2009 applies to the basic safety and essential performance of surgical luminaires and luminaires for diagnosis. It amends and supplements IEC 60601-1 (third Edition 2005), hereinafter referred to as... | |
| IEC 60601-2-41:2009+A1:2 013 applies to the basic safety and essential performance of surgical luminaires and luminaires for diagnosis. It amends and supplements IEC 60601-1 (third Edition 2005), hereinafter referred to... | |
| IEC 60601-2-43:2010 establishes particular basic safety and essential performance requirements for the design and manufacture of X ray equipment for radioscopically guided interventional procedures. It specifies information which is to... | |
| IEC 60601-2-43:2010+A1:2 017 establishes particular basic safety and essential performance requirements for the design and manufacture of X ray equipment for radioscopically guided interventional procedures. It specifies information which is... | |
| IEC 60601-2-44:2009 applies to the basic safety and essential performance of CT scanners. The scope of IEC 60601-2-44:2009 is limited to CT scanners intended to be used for both head... | |
| IEC 60601-2-44:2009+A1:2 012 applies to the basic safety and essential performance of CT scanners. The scope of IEC 60601-2-44:2009 is limited to CT scanners intended to be used for both... | |
| IEC 60601-2-44:2009+A1:2 012+A2:2016 applies to the basic safety and essential performance of CT scanners. The scope of IEC 60601-2-44:2009 is limited to CT scanners intended to be used for both... | |
| IEC 60601-2-45:2011 applies to the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices. IEC 60601-2-45:2011 addresses the system level of mammographic X-ray equipment, which consists... | |
| IEC 60601-2-45:2011+A1:2 015 applies to the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices. IEC 60601-2-45:2011 addresses the system level of mammographic X-ray equipment, which... | |
| IEC 60601-2-46:2016 is available as IEC 60601-2-46:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC... | |
| IEC 60601-2-46:2016 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60601-2-47:2012 concerns the basic safety and essential performance of AMBULATORY ELECTROCARDIOGRAPHIC SYSTEMS. It amends and supplements the general standard IEC 60601-1 (third edition 2005). The requirements of this particular... | |
| IEC 60601-2-4:2010 establishes particular basic safety and essential performance requirements for cardiac defibrillators. This third edition cancels and replaces the second edition published in 2002. This edition constitutes a technical... | |
| IEC 60601-2-4:2010+A1:20 18 establishes particular basic safety and essential performance requirements for cardiac defibrillators. This third edition cancels and replaces the second edition published in 2002. This edition constitutes a... | |
| IEC 60601-2-50:2009 establishes particular basic safety and essential performance requirements for infant phototherapy equipment, which reduce the safety hazards to patients and operators as much as possible, and specifies tests... | |
| IEC 60601-2-50:2009+A1:2 016 establishes particular basic safety and essential performance requirements for infant phototherapy equipment, which reduce the safety hazards to patients and operators as much as possible, and specifies... | |
| IEC 60601-2-52:2009 applies to the basic safety and essentialperformance of medical beds intended for adults IEC 60601-2-52:2009appli es to the basic safety and essential performance of medical beds intendedfor adults. | |
| IEC 60601-2-52:2009+A1:2 015 applies to the basic safety and essential performance of medical beds intended for adults. IEC 60601-2-52:2009 is the realization of much work in alignment, and scope adjustment... | |
| IEC 60601-2-54:2009 applies to the basic safety and essential performance of medical electrical equipment and medical electrical systems intended to be used for projection radiography and radioscopy. The minimum safety... | |
| IEC 60601-2-54:2009+A1:2 015 applies to the basic safety and essential performance of medical electrical equipment and medical electrical systems intended to be used for projection radiography and radioscopy. The minimum... | |
| IEC 60601-2-54:2009+A1:2 015+A2:2018 applies to the basic safety and essential performance of medical electrical equipment and medical electrical systems intended to be used for projection radiography and radioscopy. The minimum... | |
| IEC 60601-2-57:2011 applies to basic safety and essential performance of equipment incorporating one or more sources of optical radiation in the wavelength range 200 nm to 3 000 nm, with... | |
| IEC 60601-2-62:2013 applies to the basic safety and essential performance of HIGH INTENSITY THERAPEUTIC ULTRASOUND EQUIPMENT. This International Standard adds or replaces clauses listed in the IEC 60601-1 that are... | |
| IEC 60601-2-63:2012 applies to the basic safety and essential performance of dental extra-oral X-ray equipment, hereafter also called ME equipment. The scope includes ME systems containing such ME equipment. This... | |
| IEC 60601-2-63:2012+A1:2 017 applies to the basic safety and essential performance of dental extra-oral X-ray equipment, hereafter also called ME equipment. The scope includes ME systems containing such ME equipment. | |
| IEC 60601-2-64:2014 applies to the basic safety and essential performance of Light Ion Beam Medical Electrical equipment, hereafter referred to as ME equipment, used for treatment of patients. This particular... | |
| IEC 60601-2-65:2012 applies to the basic safety and essential performance of dental intra-oral X-ray equipment and its main components. The scope of this standard is restricted to X-ray equipment where... | |
| IEC 60601-2-65:2012+A1:2 017 applies to the basic safety and essential performance of dental intra-oral X-ray equipment and its main components. The scope of this standard is restricted to X-ray equipment... | |
| IEC 60601-2-66:2015 applies to the basic safety of hearing instruments and hearing instrument systems, hereafter also referred to as ME equipment or ME system. This second edition cancels and replaces... | |
| IEC 60601-2-68:2014 applies to the basic safety and essential performance of X-ray based image-guided radiotherapy (IGRT) equipment for use with External Beam Equipment (EBE). This particular standard covers safety aspects... | |
| IEC 60601-2-6:2012 specifies the minimum requirements considered to provide for a practical degree of safety in the operation of microwave therapy equipment. This particular standard amends and supplements IEC 60601-1... | |
| IEC 60601-2-6:2012+A1:20 16 specifies the minimum requirements considered to provide for a practical degree of safety in the operation of microwave therapy equipment. This particular standard amends and supplements IEC... | |
| IEC 60601-2-75:2017 applies to the basic safety and essential performance of photodynamic therapy and photodynamic diagnosis equipment. Hazards inherent in the intended physiological function of ME equipment or ME systems... | |
| IEC 60601-2-76:2018 applies to the basic safety and essential performance of low energy ionized gas haemostasis equipment. Hazards inherent in the intended physiological function of ME Equipment or ME Systems... | |
| IEC 60601-2-8:2010 establishes particular basic safety and essential performance requirements for therapeutic X-ray equipment with nominal X-ray tube voltages in the range 10 kV to 1 MV when connected to... | |
| IEC 60601-2-8:2010+A1:20 15 establishes particular basic safety and essential performance requirements for therapeutic X-ray equipment with nominal X-ray tube voltages in the range 10 kV to 1 MV when connected... | |
| IEC 60603-2:1995 applies to groups of related connectors for use with printed boards. They range from connectors with high contact density for low-voltage applications (Styles B and C) to connectors... | |
| IEC 60603-7-1:2011 covers 8-way shielded free and fixed connectors. It specifies the dimensions, mechanical, electrical and environmental characteristics and tests, in relation to the shield, additional to those in IEC... | |
| IEC 60603-7-2:2010 covers 8-way, unshielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements for frequencies up to... | |
| IEC 60603-7-3:2010 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7 and IEC 60603-7-1, and specifies electrical transmission requirements for... | |
| IEC 60603-7-41:2010 covers 8-way, unshielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements, including power sum alien... | |
| IEC 60603-7-4:2010 covers 8-way, unshielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements for frequencies up to... | |
| IEC 60603-7-51:2010 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements, including power sum alien... | |
| IEC 60603-7-5:2010 covers 8-way, shielded, free and fixed connectors and references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7 and IEC 60603-7-1, and specifies electrical transmission requirements... | |
| IEC 60603-7-71:2010 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements, including power sum alien... | |
| IEC 60603-7-7:2010 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7 and IEC 60603-7-1, and specifies electrical transmission requirements for... | |
| IEC 60603-7-81:2015 Covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements, including power sum alien... | |
| IEC 60603-7-82:2016 covers 8-way, 12 contacts, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7-7, and specifies electrical transmission requirements, including power... | |
| IEC 60603-7:2008 covers 8-way unshielded free and fixed connectors and is intended to specify the common dimensions, mechanical, electrical and environmental characteristics and tests for the family of IEC 60603-7-x... | |
| IEC 60603-7:2008+A1:2011 covers 8-way unshielded free and fixed connectors and is intended to specify the common dimensions, mechanical, electrical and environmental characteristics and tests for the family of IEC 60603-7-x... | |
| IEC 60603-7:2008+A1:2011 +A2:2019 covers 8-way unshielded free and fixed connectors and is intended to specify the common dimensions, mechanical, electrical and environmental characteristics and tests for the family of IEC... | |
| IEC 60613:2010 applies to X-ray tube assemblies either with a rotating anode X-ray tube or a stationary anode X-ray tube, intended for use in medical diagnosis. For an X-ray tube... | |
| IEC 60619-A2-Ed.2 Amendment No. 2 Electrically operated food preparation appliances - Methods for measuring the performance. | |
| IEC 60623:2017 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60626-1:2009 contains the definitions related to and the general requirements to be fulfilled by combined flexible materials for electrical insulation. This standard does not include mica paper, as primary... | |
| IEC 60626-2:2009 provides the test methods for combined flexible materials for electrical insulation. Some properties and relevant test methods, according to the perfomance requirements of IEC 60626-3, were confirmed. Other... | |
| IEC 60626-3:2008 gives dimensional and performance requirements for individual combined flexible materials for electrical insulation. This part is in the form of groups of sheets. This standard contains 31 sheets... | |
| IEC 60626-3:2008+A1:2012 gives dimensional and performance requirements for individual combined flexible materials for electrical insulation. This part is in the form of groups of sheets. This standard contains 31 sheets... | |
| IEC 60627:2013 is applicable to anti-scatter grids used in medical diagnostic X-ray imaging equipment. Anti-Scatter Grids are used to reduce the incidence of scattered radiation, produced particularly in the body... | |
| IEC 60633:1998+A1:2009 applies to terminology for high-voltage direct current (HVDC) systems and especially to HVDC converter substations where electronic converters are used for the conversion from a.c. to d.c. or... | |
| IEC 60633:1998+A1:2009+A 2:2015 applies to terminology for high-voltage direct current (HVDC) systems and especially to HVDC converter substations where electronic converters are used for the conversion from a.c. to d.c. | |
| IEC 60641-3-1:2008 gives the requirements for pressboard for electrical purposes comprised of 100 % sulphate wood pulp or a mixture of sulphate wood pulp and cotton. The main changes with... | |
| IEC 60644:2009 applies primarily to fuse-links used with motors started direct-on-line on alternating current systems of 50 Hz and 60 Hz. Standardizes time-current characteristics to formulate additional pulse withstand requirements... | |
| IEC 60645-1:2017 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60645-6:2009 applies to instruments designed primarily for the measurement of otoacoustic emissions in the human external acoustic meatus evoked by acoustic probe pulses or tones. This standard defines the... | |
| IEC 60645-7:2009 applies to instruments designed for the measurement of auditory evoked potentials from the inner ear, the auditory nerve and the brainstem, evoked by acoustic and/or vibratory stimuli of... | |
| IEC 60662:2011 specifies performance requirements for high-pressure sodium vapour lamps for general lighting purposes which comply with the safety requirements of IEC 62035. This second edition cancels and replaces the... | |
| IEC 60664-1:2007 Deals with insulation coordination for equipment within low-voltage systems. It applies to equipment for use up to 2 000 m above sea level having a rated voltage up... | |
| IEC 60664-3:2016 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way... | |
| IEC 60664-3:2016(E) is available as IEC 60664-3:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC... | |
| IEC 60664-4:2005 Deals with basic, supplementary and reinforced insulation subjected to high-frequency voltage stress within low-voltage equipment. The dimensioning values directly apply for basic insulation; for reinforced insulation additional requirements... | |
| IEC 60665:2018 specifies the performance and the corresponding methods of test of AC ventilating fans for household and similar purposes intended for air forcing and exhaust, driven by single-phase AC... | |
| IEC 60666:2010 provides methods concerning the detection and determination of specified additives in unused and used mineral insulating oils. The detection methods may be applied to assess whether or not... | |
| In addition to above, applicable up to 100 kHz. Resistor characterization. | |
| Intended to permit a variety of positioning devices, which respond to a linear motion, to be mounted on the actuator of a control valve, either directly or by employing an... | |
| Intended to permit a variety of positioning devices, which respond to a rotary motion, to be mounted on the actuator of a control valve, either directly or by employing an... | |
| Is a guide to the use of piezoelectric ceramic resonator units for oscillators, so that the piezoelectric ceramic resonator units may be used to their best advantage. | |
| Is applicable to electrical connectors, sockets, cable assemblies or interconnection systems. Describes a frequency and a time domain method to measure return loss as a function of frequency. | |
| It applies to the design of operating and environmental test cycles referred to in 8.1 and 8.2 of IEC 605-1. | |
| It defines the testing and reporting of the step response of control valves that are used in throttling closed-loop control applications. A control valve consists of the complete, ready-to-use assembly... | |
| It is applicable to printed board connectors designed for use in equipment for telecommunication and electronic data processing and in electronic equipment or devices employing similar techniques. The object is... | |
| It specifies manufacturing tolerances for extension and compensating cables (other than mineral insulated cables) provided directly to users of industrial processes. These tolerances are determined with respect to the e.m.f.-temperature... | |
| Lays down minimum performance requirements for headphones and earphones primarily intended for high-quality reproducing systems for home use. Applies to headphones and earphones with devices, if any, such as preamplifiers,... | |
| Lays down requirements common to installations using the effect of electromagnetic forces on liquid metals; specific requirements for electromagnetic pouring equipment; specific requirements for electromagnetic equipment with lining. The significant... | |
| Lays down the minimum requirements for microphones intended for high-quality reproducing systems for home use. | |
| Lists environmental climatic conditions e.g. air temperature humidity and air pressure in specified locations to which land-based and offshore industrial-process measurement and control systems may be exposed during operation, during... | |
| Methods are given for the measurement of the electrical characteristics of frequency demodulators. Threshold and carrier-to-noise measurements are included because these are essential for satellite systems. Where possible, only measurements... | |
| Methods are given for the measurement of the electrical characteristics of frequency modulators. Furthermore, where possible, only measurements involving the basic modulator are considered, excluding the baseband section comprising the... | |
| NEW! IEC 60598-2-4:2017 is available as IEC 60598-2-4:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. | |
| NEW! IEC 60601-2-16:2018 is available as IEC 60601-2-16:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC... | |
| NEW! IEC 60601-2-28:2017 is available as IEC 60601-2-28:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC... | |
| NEW! IEC 60601-2-2:2017 is available as IEC 60601-2-2:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC... | |
| NEW! IEC 60601-2-39:2018 is available as IEC 60601-2-39:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC... | |
| NEW! IEC 60623:2017 is available as IEC 60623:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC... | |
| NEW! IEC 60645-1:2017 is available as IEC 60645-1:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC... | |
| Primarily intended for the manufacturer. Not applicable to generators with pulsed sinusoidal outputs, television pattern generators, complex function generators, and generators for insulation resistance testing. Lays down a standard list... | |
| Provides a basis for the formulation of guarantees applied to cavitation pitting for reaction hydraulic turbines, storage pumps and pump-turbines. It addresses the measurement and evaluation of the amount of... | |
| Provides a classification system that serves as a guide for the selection and indexing of insulating materials intended to serve in the radiation environment of nuclear reactor facilities, reactor fuel-processing... | |
| Provides guidance for the design of in-core instrumentation for neutron fluence rate measurements in thermal neutron reactors designed for power production. Applies to on-line in-core neutron detectors, together with associated... | |
| Provides statistical methods for evaluating point estimates, confidence intervals, prediction intervals and tolerance intervals for the failure rate of items whose time to failure follows an exponential distribution. | |
| Refers specifically to mobile radio transmitters and receivers for the transmission of data (telegraphy) signals. Is intended to be used in conjunction with IEC 60489-1. The terms and definition and... | |
| Reviews admittance characteristics and equivalent circuits of ceramic resonators vibrating in simple modes. Contains methods for determining resonator parameters and material constants. | |
| Specifies end-to-end dimensions for given nominal sizes and pressure ratings of buttweld, two-way, global-type, straigth pattern control valves for nominal sizes DN 15 through DN 450. Aids users in their... | |
| Specifies face-to-face (FTF) and centre-to-face (CTF) dimensions for given nominal sizes and pressure ratings of flanged, two-way, globe-type, straight pattern and angle pattern control valves. | |
| specifies mandatory and supplementary markings of control valves. Some mandatory markings may be inappropriate for some valves of special design, and some supplementary markings may be appropriate only to specific... | |
| Specifies methods for calibration of hydrophones or reversible transducers when used as a hydrophone, particularly in the frequency range from 0,01 Hz to 1 MHz. Rules for the presentation of... | |
| Specifies methods of test to be used for testing varnishes used for electrical insulation. This includes methods of test to be applied before and others to be applied after drying... | |
| Specifies procedures to verify the assumption of a constant failure rate or constant failure intensity as defined in IEC 60050(191). These procedures are applicable whenever it is necessary to verify... | |
| Specifies requirements for extra low voltage systems for filament lamps intended for ordinary use on supply voltages not exceeding 1 000 V. The luminaires, being connected in parallel, are supplied... | |
| Specifies requirements for fixed general purpose luminaires for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V. | |
| Specifies requirements for fixed luminaires intended for use in water, or in contact with water, for example in swimming pools, fountains, paddling pools, and garden pools, and for use with... | |
| Specifies requirements for flat vulcanized fibre sheets. Not applicable to material made by combining with an adhesive several thicknesses of vulcanized fibre sheet. | |
| Specifies requirements for luminaires for road and street lighting, for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V. | |
| Specifies requirements for photo and film luminaires (non-professional) for use with low-pressure tungsten halogen lamps, specified in IEC 60357. | |
| Specifies requirements for portable child-appealing luminaires for use with tungsten filament lamps on supply voltages not exceeding 24 V (SELV). | |
| Specifies safety requirements for air-handling luminaires for use with a ventilation space (plenum), for use with tubular fluorescent lamps on supply voltages not exceeding 1 000 V. | |
| Specifies tests and requirements for sealed nickel-cadmium prismatic rechargeable single cells. | |
| Specifies the construction, dimensions and test requirements of power cables with extruded solid insulation for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6... | |
| Specifies the performance and testing of dose area product meters with ionization chambers intended to measure dose area product and/or dose area product rate to which the patient is exposed... | |
| Specifies the performance and the corresponding methods of test of ventilating fans for household and similar purposes intended for air forcing and exhaust, not exceeding 0.5 m in size, driven... | |
| specifies the requirements for the inspection and routine testing of control valves manufactured in conformity with the other parts of IEC 60534.is applicable to valves with pressure ratings not exceeding... | |
| States and defines the principal performance characteristics of electric warming plates which are of interest to the user, and describes the standard methods for measuring these characteristics. Contains objective dimensions... | |
| Summarizes the present position on difference in limits and attitudes towards non-ionizing hazards adopted by a number of different countries, and by the IEC and other international organizations, in standards... | |
| The contents of the corrigendum of December 1980 have been included in this copy. | |
| The contents of the corrigendum of July 2014 have been included in this copy. IEC TR 62348:2012 provides a tool to assist users of IEC 60601-1:2005 to assess the impact... | |
| The method described uses the change of electrical characteristics of askarels to eliminate those materials which are not suitable owing to their contaminating effect on the askarels. | |
| The method described uses the changes of electrical and/or chemical characteristics of askarels, as well as various physical tests on materials exposed to askarels, in order to eliminate those materials... | |
| The purpose of this guide is to assist the power equipment operator in evaluating askarels in transformers, reactors and accessory equipment operated at power frequencies and in his efforts to... | |
| This collateral standard applies to X-ray equipment and to subassemblies of such equipment, where radiological images of a human patient are used for diagnosis, planning or guidance of medical procedures. | |
| This Dual Logo International Standard is the result of an agreement between the IEC and the Institute of Electrical and Electronics Engineers, Inc. (IEEE). The original IEEE Standard was submitted... | |
| This International Standard comprises maximum lamp outlines for incadescent lamps (including tungsten-halogen lamps). This consolidated version consists of the second edition (1994), its amendment 1 (1997), its amendment 2 (1998),... | |
| This International Standard comprises maximum lamp outlines for incadescent lamps (including tungsten-halogen lamps). This consolidated version of IEC 60630 is based on the second edition (1994) and its amendments 1... | |
| This Part 2 of IEC 60598 specifies requirements for ground recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V, for indoor or outdoor... | |
| This part of IEC 60641 contains definitions related to a classification of, and the general requirements to be fulfilled by, pressboard and presspaper for electrical purposes. The main changes with... | |
| This part of IEC 60641 gives the requirements for presspaper for electrical purposes comprised of 100 % sulphate wood pulp, 100 % cotton or a mixture of sulphate wood pulp... | |
| This part of IEC 60645 specifies a means of describing the physical characteristics of audiometric reference and test signals of short duration and methods for their measurement. The object of... | |
| This Particular Standard specifies requirements and tests for the safety of ultrasonic physiotherapy equipment. It amends and supplements IEC 60601-1 (second edition, 1988) including Amendments 1 and 2, hereinafter referred... | |
| This section deals with baseband-to-baseband measurements for frequency division multiplex (f.d.m.) telephony. These measurements are additional to those given in part 1, section four of this publication, which are common... | |
| This sheet specifies requirements for hot curing impregnating varnishes and includes requirements for certain properties at elevated temperatures. | |
| This standard applies to microwave measuring apparatus and microwave measuring techniques. | |
| This standard applies to track systems for ordinary interior use with two or more poles and with provision for earthing (Class 1), with a rated voltage not exceeding 440 V... | |
| This standard serves as a basis for the formulation of guarantees on cavitation pitting on Pelton turbine runners. It also provides a basis for the measurement and evaluation of the... | |
| Untitled DocumentSpecifies basic safety and essential performance requirements and tests for alarm systems in medical electrical equipment and medical electrical systems and to provide guidance for their application. This is... | |
| Untitled DocumentSpecifies requirements for the development (analysis, design, verification and validation) of a physiologic closed-loop controller (PCLC) as part of a physiologic closed-loop control system (PCLCS) in medical electrical equipment... |