ENMET Corporation Datasheets for Gas Transmitters

Gas transmitters consist of an enclosure, sensor, and electronics that convert a signal from a gas sensor into an analog output signal (typically 4-20 mA).
Gas Transmitters: Learn more

Product Name Notes
IR-6000 Infrared Hydrocarbon Sensor/Transmitter The IR-6000 hydrocarbon detector is a single source dual wavelength instrument. The sensing and reference elements are self-compensating for optical integrity and other signal inhibitors. The...
ISA-60M 1-3 Channel Oxygen Monitor with MRI-5175 O2 Sensor/Transmitter General Specifications Features Long-life oxygen sensor The ISA-60M has 3 channel capacity utilizing 4-20 mA; Up to 4 channels can be...
P/N 10013-0100, EX-5130 Sensor/Transmitter for Reactive Gas in Hazardous Locations, Br2 The EX-5130 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte...
P/N 10013-0100, EX-5130 Sensor/Transmitter for Reactive Gas in Hazardous Locations, Cl2 The EX-5130 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte...
P/N 10013-0400, EX-5130 Sensor/Transmitter for Reactive Gas in Hazardous Locations, HBr The EX-5130 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte...
P/N 10013-0400, EX-5130 Sensor/Transmitter for Reactive Gas in Hazardous Locations, HCl The EX-5130 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte...
P/N 10013-0700, EX-5130 Sensor/Transmitter for Reactive Gas in Hazardous Locations, HF The EX-5130 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte...
P/N 10013-0800, EX-5130 Sensor/Transmitter for Reactive Gas in Hazardous Locations, O3 The EX-5130 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte...
P/N 10013-4001, EX-5130 Sensor/Transmitter for Reactive Gas in Hazardous Locations, AsH3 The EX-5130 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte...
P/N 10013-5200, EX-5130 Sensor/Transmitter for Reactive Gas in Hazardous Locations, ETO The EX-5130 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte...
P/N 10014-001, EX-5100 Combustible Gas Sensor/Transmitter 0-100% LEL The EX-5100 incorporates a pellistor or catalytic bead sensor. This sensor consists of a matched pair of elements, one active and the...
P/N 10014-003, EX-5120 Infrared Hydrocarbon Sensor/Transmitter The EX-5120 incorporates a sensor that operates on the NDIR principle to monitor the concentration of hydrocarbon gas. It can be calibrated for a...
P/N 10014-008, EX-5150-MOS Sensor/Transmitter for PPM Hydrocarbons and Organic Solvents An MOS sensor consists of a heated mixed metal oxide element that decreases in resistance in the presence of many...
P/N 10014-018, EX-5155 Sensor/Transmitter for Toxic Hydrocarbons & Organic Solvents An MOS sensor consists of a heated mixed metal oxide element that decreases in resistance in the presence of many...
P/N 10014-0200, EX-5175 Explosionproof Sensor/Transmitter, H2S The EX-5175 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier.
P/N 10014-024, EX-5165 Infrared Sensor/Transmitter for Carbon Dioxide, CO2 The EX-5165 incorporates a miniature NDIR type sensor for the measurement of carbon dioxide concentrations ranging from 500 ppm to 100%...
P/N 10014-0500, EX-5175 Explosionproof Sensor/Transmitter, SO2 The EX-5175 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier.
P/N 10014-1100, EX-5175 Explosionproof Sensor/Transmitter, O2 The EX-5175 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier.
P/N 10014-1200, EX-5175 Explosionproof Sensor/Transmitter, CO The EX-5175 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier.
P/N 10014-1500, EX-5175 Explosionproof Sensor/Transmitter, H2 The EX-5175 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier.
P/N 10014-1700, EX-5175 Explosionproof Sensor/Transmitter, NO2 The EX-5175 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier.
P/N 10014-2400, EX-5175 Explosionproof Sensor/Transmitter, NH3 The EX-5175 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier.
P/N 10017-1750, EX-5175 Explosionproof Sensor/Transmitter, NO The EX-5175 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier.
P/N 10022-0100, SDS-97D Series Sensor/Transmitter Chlorine, Cl2 Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant Optional...
P/N 10022-0200, SDS-97D Series Sensor/Transmitter Hydrogen Sulfide, H2S Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant...
P/N 10022-0400, SDS-97D Series Sensor/Transmitter Hydrogen Chloride, HCl Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant...
P/N 10022-0500, SDS-97D Series Sensor/Transmitter Sulfur dioxide, SO2 SDS-97D Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation...
P/N 10022-0700, SDS-97D Series Sensor/Transmitter Hydrogen Fluoride, HF Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant...
P/N 10022-0803, SDS-97D Series Sensor/Transmitter Ozone, O3 SDS-97D Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier.
P/N 10022-1100, SDS-97D Series Sensor/Transmitter Oxygen, O2 Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant Optional...
P/N 10022-1200, SDS-97D Series Sensor/Transmitter Carbon Monoxide, CO Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant...
P/N 10022-1500, SDS-97D Series Sensor/Transmitter Hydrogen, H2 Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant Optional...
P/N 10022-1700, SDS-97D Series Sensor/Transmitter Nitrogen Dioxide, NO2 Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant...
P/N 10022-1750, SDS-97D Series Sensor/Transmitter Nitric Oxide, NO Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant...
P/N 10022-2400, SDS-97D Series Sensor/Transmitter Ammonia, NH3 Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant Optional...
P/N 10022-4001, SDS-97D Series Sensor/Transmitter Arsine, AsH3 Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant Optional...
P/N 10022-4003, SDS-97D Series Sensor/Transmitter Silane, SiH4 SDS-97D Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier.
P/N 10022-5200, SDS-97D Series Sensor/Transmitter Ethylene Oxide, ETO Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant...
P/N 10050-1331, CD-1300-ST Carbon Dioxide Sensor/Transmitter The CD-1300-ST Sensor/Transmitter is easy to install and maintain. The output signal is 4-20 mA or an optional 0 to 10 volt interface. The...