IEC - International Electrotechnical Commission Datasheets for Standards and Technical Documents

Standards and technical documents includes standards, codes, regulation, handbooks, manuals, comprehensive guides and other formal publications. Standards, codes, and regulation establish uniform specifications, procedures or technical criteria.
Standards and Technical Documents: Learn more

Page: 1 10 20 29 30 31 32 33 34 35 36 37 38 39 40 41 50 60 63
Product Name Notes
Applies to adjustable speed a.c. drive systems that include power conversion, control equipment and a motor. Excluded are traction for railway applications and electrical vehicle drives. Applies to power drive...
Applies to all electronic components covered by the IEC system which require an assessment with respect to their application to surface mounting. Gives a reference set of process conditions and...
Applies to all line-commutated high-voltage direct current (HVDC) converter stations used for power exchange in utility systems. Presumes the use of 12-pulse thyristor converters but can also be used for...
Applies to electromechanical elementary relays (non-specified time all-or-nothing relays) and defines the basic safety-related and functional requirements for applications in all areas of electrical engineering or electronics.
Applies to general purpose adjustable speed a.c. drive systems which include power conversion, control equipment, and also an a.c. motor or motors. Excluded are tractional and electrical vehicle drives. Applies...
Applies to general purpose adjustable speed d.c. driven systems which include the power conversion, control equipment, and also a motor or motors. Excluded are traction and electrical vehicle drives. Applies...
Contains general information concerning connector interfaces (definitions, dimensioning system, tolerance grades, etc.).
Contains the minimum initial test and measurement requirements and severities which a fibre optic attenuator must satisfy in order to be categorised as meeting the requirements of single mode fibre...
Contains the minimum requirements and severities which a fibre optic circulator shall satisfy in order to be categorised as meeting the requirements of circulator devices used in uncontrolled environments. The...
Contains the minimum requirements and severities which a single-mode connector/cable assembly must satisfy in order to be considered as meeting category U (uncontrolled environment). Also contains optional grades of optical...
Covers a test method detailing the tensile test procedures to be carried out on Cu/Nb-Ti superconductive composite wires at room temperature. This test is used to measure modulus of elasticity,...
Covers a test method for the determination of copper to superconductor volume ratio of Cu/Nb-Ti composite superconducting wire. The Cu/Nb-Ti composite test conductor discussed in this method has a monolithic...
Covers a test method for the determination of the d.c. critical current of Cu/Nb-Ti composite superconductors that have a copper/superconducto r ratio larger than 1. This method is intended for...
Covers a test method for the determination of the d.c. critical current of Nb3Sn composite superconductors which are fabricated by either the bronze process or the internal tin diffusion process...
Covers a test method for the determination of the d.c. critical current of short and straight Ag- or Ag alloy-sheathed Bi-2212 and Bi-2223 oxide superconductors that have a monolithic structure...
Covers a test method for the determination of the residual resistance ratio (RRR) of Nb3Sn composite conductors. This method is intended for use with superconductor specimens that have a monolithic...
Covers general information on fibre optic connector performance standards. Includes references, definitions and rules for creating a performance standard, as well as additional information pertinent to the subject.
Covers optical fibres components and subassemblies as they pertain specifically to sensing applications, in those aspects not already addressed by previous or concurrent standardization efforts. Defines, classifies and provides the...
Covers test conditions and provisions for the evaluation of endurance tests using appropriate statistical methods to obtain reliability characteristics for relays.
Defines a set of prescribed conditions that must be maintained in order to satisfy the requirements of attenuation and return loss performance in a randomly mated pair of fibres. Performance...
defines a set of protocol specific communication profiles based primarily on the IEC 61158 series, to be used in the design of devices involved in communications in factory manufacturing and...
Defines the standard interface dimensions for the type CF08 family of connectors which is a single-way plug connector, characterized by a conical ferrule butting against a sphere. It includes a...
Defines the standard interface dimensions for the type FC-PC family of connectors. The parent connector for type FC connector family is a single position plug connector set of plug/adapter configuration...
Defines the standard interface dimensions for the type FS connector family which is a duplex connector set of plug and adaptor configuration. The plug has a pair of cylindrical spring...
Defines the standard interface dimensions for the type LC family of connectors.
Defines the standard interface dimensions for the type LSH family of connectors. The parent connector for the type LSH connector family is a single-position plug connector which is characterized by...
Defines the standard interface dimensions for the type LX.5 family of connectors.
Defines the standard interface dimensions for the type Mini-MPO family of connectors characterized by a rectangular ferrule nominally 4,4 x 2,5 mm which utilize two pins of 0,7 mm diameter...
Defines the standard interface dimensions for the type Mini-MPO family of connectors.
Defines the standard interface dimensions for the type MT family of connectors.
Defines the standard interface dimensions for the type SG family of connectors.
Defines the standard interface dimensions for the type SMI (small multimedia interface) family of connectors.
Defines the standard interface dimensions for type BFOC/2,5 family of connectors which is a single position plug connector characterized by a 2,5 mm nominal ferrule diameter.
Defines the standard interface dimensions for type MPO family of connectors which is a multiway plug connector characterized by a rectangular ferrule normally 6,4 mm x 2,5 mm.
Defines the standard interface dimensions for type MPO family of connectors.
Defines the standard interface dimensions for type MT family of connectors which is a multi-way plug connector characterized by a rectangular ferrule (typically 2,5 m by 6,4 mm).
Defines the standard interface dimensions for type MU family of connectors which is a miniature single-position plug characterized by a cylindrical, spring loaded butting ferrule and a push-pull coupling mechanism.
Defines the standard interface dimensions for type PN family of connectors which is a duplex plug connector characterized by a 10,16 mm pitch, and a 2,5 mm nominal ferrule diameter.
Defines the standard interface dimensions for type SC family of connectors which is characterized by a 2,5 mm nominal ferrule diameter and includes a push-pull coupling mechanism which is spring...
Describes a "reference" method for the determination of the residual resistance ratio (RRR) of a composite superconductor comprised of Nb-Ti filaments and Cu, Cu-Ni or Cu/Cu-Ni matrix. This method is...
Describes considerations for the measurement of hysteretic loss in Cu/Nb-Ti multifilamentary composites using DC- or low-ramp-rate magnetometry. Focuses on the measurement of hysteretic loss in multifilamentary Cu/Nb-Ti composite conductors. Measurements...
Describes measurement of the surface resistance of superconductors at microwave frequencies by the standard two-resonator method. The object of measurement is the temperature dependence of Rs at the resonant frequency.
Describes the test method for determining the copper to non-copper volume ratio of Cu/Nb3Sn wires. The test method given hereunder is applicable to Nb3Sn composite superconducting wires with a cross-sectional...
Describes the transportation and storage conditions for surface mounting devices (SMDs) that are fulfilled in order to enable trouble free processing of surface mounting devices, both active and passive. The...
Gives guidance on the selection, installation, use and maintenance of electrically operated group II apparatus for the detection and measurement of flammable gases complying with the requirements of IEC 61779-1...
IEC 61753-052-6:2016 contains the minimum initial test and measurement requirements and severities which a fibre optic attenuator satisfies in order to be categorised as meeting the requirements of single-mode fibre...
IEC 61753-053-02: 2022 contains the minimum initial test and measurement requirements and severities which non-connectorized single-mode fibre electrically controlled variable optical attenuator needs to satisfy in order to be categorised...
IEC 61753-053-2:2014 contains the minimum initial test and measurement requirements and severities which non-connectorized single-mode fibre electrically controlled variable optical attenuator needs to satisfy in order to be categorised as...
IEC 61753-056-2:2012 contains the minimum initial test and measurement requirements and severities which a fibre optical fuse satisfies in order for it to be categorised as meeting the requirements of...
IEC 61753-057-2:2012 contains the minimum initial test and measurement requirements and severities which a fibre optical fuse satisfies in order to be categorised as meeting the requirements of single mode...
IEC 61753-058-2:2013 contains the minimum initial test and measurement requirements and severities which an optical power limiter needs to satisfy in order to be categorized as meeting the requirements of...
IEC 61753-059-2:2013 contains the minimum initial test and measurement requirements and severities which an optical power limiter needs to satisfy in order to be categorized as meeting the requirements of...
IEC 61753-061-2:2012 contains the minimum test and measurement requirements and severities which a fibre optic isolator as specified by IEC 61202-1 should satisfy in order to be categorized as meeting...
IEC 61753-061-2:2020 contains the minimum test and measurement requirements and severities which a fibre optic isolator as specified by IEC 61202-1 satisfies in order to be categorized as meeting the...
IEC 61753-061-2:2020 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61753-071-02:2020 contains the minimum initial test and measurement requirements and severities which non-connectorized single-mode fibre optic 1 × 2 and 2 × 2 spatial switches need to satisfy in...
IEC 61753-071-02:2020+AM D1:2024 CSV contains the minimum initial test and measurement requirements and severities which non-connectorized single-mode fibre optic 1 × 2 and 2 × 2 spatial switches need to...
IEC 61753-071-2:2014 contains the minimum initial test and measurement requirements and severities which non-connectorized single-mode fibre optic 1 x 2 and 2 x 2 spatial switches need to satisfy in...
IEC 61753-081-02:2023 contains the minimum initial test and measurement requirements and severities which a fibre optic middle-scale 1 × N (16 ≤ N ≤ 64) DWDM (dense wavelength division multiplexing)...
IEC 61753-081-03:2023 contains the minimum initial test and measurement requirements and severities which a fibre optic middle-scale 1 × N (16 ≤ N ≤ 64) DWDM (dense wavelength division multiplexing)...
IEC 61753-081-06:2023 contains the minimum initial test and measurement requirements and severities which a fibre optic middle-scale 1 × N (16 ≤ N ≤ 64) DWDM (dense wavelength division multiplexing)...
IEC 61753-081-2:2009(E) contains the minimum initial test and measurement requirements and severities which a fibre optic middle-scale 1 x N (16 ≤ N ≤ 64) DWDM (Dense Wavelength Division Multiplexing)...
IEC 61753-081-2:2014 contains the minimum initial test and measurement requirements and severities which a fibre optic middle-scale 1 x N (16 ≤N ≤64) DWDM (dense wavelength division multiplexing) device with...
IEC 61753-082-02:2024 contains the minimum initial test, measurement requirements and severities which a fibre optic 1,31/1,55 µm wide wavelength division multiplexing (WWDM) device satisfies in order to be categorised as...
IEC 61753-082-2:2008 gives the minimum initial test and measurement requirements and severities which a fibre optic 1,31/1,55 μm WWDM (wide wavelength division multiplexing) device shall satisfy in order to be...
IEC 61753-085-02:2021 contains the minimum initial test and measurement requirements and severities which a fibre-optic pigtailed coarse wavelength division multiplexing (CWDM) device satisfies in order to be categorised as meeting...
IEC 61753-085-2:2008 contains the minimum initial test and measurement requirements and severities which a fibre optic pigtailed coarse wavelength division multiplexing (CWDM) device needs to satisfy in order to be...
IEC 61753-086-2:2009 contains the minimum initial performance, test and measurement requirements and severities which a fibre optic pigtailed 1 490 / 1 550 nm downstream and 1 310 nm upstream...
IEC 61753-086-6:2010 contains the minimum initial performance, test and measurement requirements and severities which a fibre optic pigtailed 1 490 / 1 550 nm downstream and 1 310 nm upstream...
IEC 61753-087-2:2010 contains the minimum initial performance, test and measurement requirements and severities which a fibre optic pigtailed 1 310 nm upstream and 1 490 nm downstream wide wavelength division...
IEC 61753-087-6:2012 contains the minimum initial performance, test and measurement requirements and severities which a fibre optic pigtailed 1 310 nm upstream and 1 490 nm downstream wide wavelength division...
IEC 61753-088-2:2013 contains the minimum initial test and measurement requirements and severities which a non-connectorized single-mode fibre optic Local Area Network Wavelength Division Multiplexing (LAN WDM) device with channel spacing...
IEC 61753-089-02:2022 contains the minimum initial test and measurement requirements and severities which a fibre-optic pigtailed wide wavelength division multiplexing (WWDM) device for monitoring passive optical networks (PON) using an...
IEC 61753-089-2:2013 contains the minimum initial performance, test and measurement requirements and severities which a fibre optic pigtailed wide wavelength division multiplexing (WWDM) device for monitoring passive optical networks (PON)...
IEC 61753-091-02:2022 contains the minimum test and measurement requirements and severities which a fibre optic circulator as specified by IEC 62077 is expected to satisfy in order to be categorized...
IEC 61753-091-2:2012 contains the minimum test and measurement requirements and severities which a fibre optic circulator as specified by IEC 62077 should satisfy in order to be categorized as meeting...
IEC 61753-1 deals with performance standards for all passive fibre optic products, including connectors, passive optical components, fibre management systems and closures. It defines those tests and severities which form...
IEC 61753-1-3:2014 defines the minimum initial performance, test and measurement requirements and severities which a connector or cable assembly with single-mode fibres needs to satisfy in order to be categorized...
IEC 61753-101-03:2021 contains the minimum tests, test severities and measurement requirements which a fibre management system need to meet in order to be categorised as meeting the IEC standard, category...
IEC 61753-111-07:2021 contains the minimum tests, test severities and measurement requirements which a sealed fibre optic closure need to meet in order to be categorised as meeting the IEC standard...
IEC 61753-111-08:2021 contains the minimum tests, test severities and measurement requirements which a sealed fibre optic closure need to meet in order to be categorised as meeting the IEC standard...
IEC 61753-111-09:2021 contains the minimum tests, test severities and measurement requirements which a sealed fibre optic closure need to meet in order to be categorised as meeting the IEC standard...
IEC 61753-111-7:2009 contains the minimum test and measurement requirements and severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting the IEC standard for...
IEC 61753-111-8:2009 contains the minimum test and measurement requirements and severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting the IEC standard for...
IEC 61753-111-9:2009 contains the minimum test and measurement requirements and severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting the IEC standard for...
IEC 61753-121-2:2010 specifies the test requirements for finished cable assemblies for use as patchcords, work area cords and equipment cords for applications in a controlled (C) environment according to IEC...
IEC 61753-121-2:2017 specifies the test requirements for cords including reference cords used in a controlled (Category C) environment according to IEC 61753-1, where the connectors already comply with the Category...
IEC 61753-121-3:2010 specifies the test requirements for finished cable assemblies for use as patchcords, work area cords and equipment cords for applications in a uncontrolled (U) environment according to IEC...
IEC 61753-131-03:2021 contains the minimum tests, test severities and measurement requirements which a mechanical fibre splice need to satisfy in order to be categorised as meeting the requirements of single-mode...
IEC 61753-131-3:2010 contains the minimum initial test and measurement requirements and severities which a mechanical fibre splice will satisfy in order to be categorised as meeting the requirements of single-mode...
IEC 61753-141-2:2011 contains the minimum test and measurement requirements and severity levels that a fibre optic passive chromatic dispersion compensator (PCDC) using single-mode dispersion compensating fibre (DCF) must satisfy in...
IEC 61753-143-2:2012 contains the minimum test and measurement requirements and severity levels that a passive chromatic dispersion compensator (PCDC) using virtually imaged phased array (VIPA) must satisfy in order to...
IEC 61753-1:2018 provides guidance for the drafting of performance standards for all passive fibre optic products. This document defines the tests and severities which form the performance categories or general...
IEC 61753-1:2018 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61753-1:2018+A1:2020 provides guidance for the drafting of performance standards for all passive fibre optic products. This document defines the tests and severities which form the performance categories or general...
IEC 61753-381-2:2016 contains the minimum initial test and measurement requirements and severities which a Gaussian-passband-pr ofile cyclic arrayed waveguide grating (AWG) for single-mode and bidirectional transmission systems satisfies in order...
IEC 61753-381-6:2016 contains the minimum initial test and measurement requirements and severities which a Gaussian-passband-pr ofile cyclic arrayed waveguide grating (AWG) for single bidirectional transmission systems satisfies in order to...
IEC 61753-382-2:2015 contains the minimum initial performance, test and measurement requirements and severities which a fibre optic pigtailed wide wavelength division multiplexing (WWDM) device for combining and splitting gigabit-capable passive...
IEC 61754-13:2024 CMV contains both the official standard and its commented version. The commented version provides you with a quick and easy way to compare all the changes between IEC...
IEC 61754-13:2024 defines the standard interface dimensions for the type FC-PC family of connectors. This third edition cancels and replaces the second edition published in 2006. This edition constitutes a...
IEC 61754-15:2009 defines the standard interface dimensions for the type LSH family of connectors. The main changes with regard to the previous edition are to reconsider the figures and the...
IEC 61754-18:2001 defines the standard interface dimensions for the type MT-RJ family of connectors. Keywords: type MT-RJ family of connectors
IEC 61754-1:2013 covers general information on the subject of fibre optic connector interfaces. It includes references, definitions and rules for creating and interpreting the standard drawings. This second edition cancels...
IEC 61754-20-100:2012 covers connectors with protective housings. The housing is defined as variant 4 in IEC 61076-3-106:2006. These connectors use a push-pull coupling mechanism. To connect the fibres inside the...
IEC 61754-20:2012 defines the standard interface dimensions for the type LC family of connectors. The changes with respect to the previous edition are to reconsider the whole document and to...
IEC 61754-20:2012+AMD1:2 022 CSV defines the standard interface dimensions for the type LC family of connectors. The changes with respect to the previous edition are to reconsider the whole document...
IEC 61754-24-11:2009 serves as an interface standard and describes an SC-RJ fibre optic connector equipped with a protective housing for upgrading the existing interface described in IEC 61754-24 to IP65...
IEC 61754-24-21:2009 serves as an interface standard and describes an SC-RJ fibre optic connector equipped with a protective housing based on IEC 61076-3-106, variant 06, for upgrading the existing interface...
IEC 61754-24:2009 defines the standard interface dimensions for the type SC-RJ family of connectors.
IEC 61754-25:2008 defines the standard interface dimensions for the type RAO family of connectors.
IEC 61754-26:2012 defines the standard interface dimensions for the type SF optical board connector that uses a normal glass fibre and the physical contact technique to connect flexible optical boards...
IEC 61754-27:2013 defines the standard interface dimensions for the type M12-FO family of connectors. This connector is of duplex plug/adaptor/plug configuration and designed for industrial environment as described in ISO/IEC/TR...
IEC 61754-28:2012 defines the standard interface dimensions for the type LF3 family of connectors.
IEC 61754-29:2012 defines the standard interface dimensions for the type BLINK series of connectors.
IEC 61754-30:2014 defines the standard interface dimensions for the type CLIK series of connectors. Keywords: interface dimensions, type CLIK, connectors
IEC 61754-31:2016 defines the standard connector interface dimensions for the two way and four way type N-FO family of connectors. Keywords: standard connector interface dimensions for the two way and...
IEC 61754-32:2016 defines the standard interface dimensions for the type DiaLink family of connectors. Keywords: interface dimensions for the type DiaLink family of connectors
IEC 61754-34:2016 defines the standard interface dimensions for the type URM family of connectors. Keywords: interface dimensions for type URM connectors
IEC 61754-35: 2020 defines the standard connector interface dimensions for LSHE family of connectors with up to four termini. This connector family is targeting deployment under harsh environmental conditions.
IEC 61754-3:1996 defines the standard interface dimensions for type LSA family of connectors. Keywords: interface dimensions for type LSA family of connectors
IEC 61754-4-100:2015 specifies the standard simplified receptacle interface dimensions for the type SC connector family. The receptacle assembly consists of a simplified receptacle housing and a simplified plug. Keywords: interface...
IEC 61754-4-1:2003 defines the standard interface dimensions of simplified receptacles for the type SC family of connectors. The parent connector for the type SC connector family is a single-position plug...
IEC 61754-4:2013 defines the standard interface dimensions for type SC family of connectors. This second edition cancels and replaces the first edition published in 1997 and constitutes a technical revision.
IEC 61754-4:2021 specifies the standard interface dimensions for type SC family of connectors. This third edition cancels and replaces the second edition published in 2013 and constitutes a technical revision.
IEC 61754-4:2022 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61754-6-100:2015 defines the standard interface dimensions of simplified receptacle dimensions for the type MU connector family. The receptacle assembly consists of a simplified receptacle housing and a simplified plug.
IEC 61754-6-1:2003 defines the standard interface dimensions of simplified receptacles for the type MU family of connectors. Keywords: interface dimensions of simplified receptacles for type MU connectors.
IEC 61754-6:2013 defines the standard interface dimensions for type MU family of connectors. This second edition cancels and replaces the first edition published in 1997 and constitutes a technical revision.
IEC 61754-6:2022 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61754-6:2022 specifies the standard interface dimensions for type MU family of connectors. This third edition cancels and replaces the second edition published in 2013 and constitutes a technical revision.
IEC 61754-7-1:2014 defines the standard interface dimensions for type MPO family of connectors with one row of fibres. This first edition of IEC 61754-7-1, along with the first edition of...
IEC 61754-7-2:2017 defines the standard interface dimensions for the type MPO family of connectors with two rows of fibres. This first edition of IEC 61754-7-2, along with the first edition...
IEC 61754-7-3: 2019 defines the standard interface dimensions for type MPO family of connectors with two rows of 16 fibres. Keywords: interface dimensions for type MPO connectors
IEC 61754-7:2008 defines the standard interface dimensions for type MPO family of connectors. This third edition cancels and replaces the second edition published in 2004. This third edition constitutes a...
IEC 61754-9:1996 defines the standard interface dimensions for type DS family of connectors. Keywords: interface dimensions for type DS family of connectors.
IEC 61755-1:2022 covers dispersion unshifted single-mode fibre optic connection interfaces. It includes references, document structure details, definitions, and standardised optical connection grades. The grades are based on random mated connections...
IEC 61755-2-1:2022 defines a set of prescribed conditions for a single-mode fibre optic connection that is maintained in order to satisfy the requirements of attenuation and return loss (RL) performance...
IEC 61755-2-2:2022 defines a set of prescribed conditions for a single-mode fibre optic connection that is maintained in order to satisfy the requirements of attenuation and return loss (RL) performance...
IEC 61755-2-4:2015 defines a set of prescribed conditions that should be maintained in order to satisfy the requirements of non-angled polished reference connections. The prescribed conditions include dimensional limits and...
IEC 61755-2-5:2015 defines a set of prescribed conditions that should be maintained in order to satisfy the requirements of angled polished reference connections. The prescribed conditions include dimensional limits and...
IEC 61755-3-10: 2016 defines certain dimensional limits of a 125 mm diameter single mode silica fibre optical interface and an alignment bore to meet specific requirements for non-angled fibre-to-fibre interconnection...
IEC 61755-3-1:2024 defines the dimensional limits of the optical interface that are necessary for single-mode fibre optic connectors with 2,5 mm or 1,25 mm diameter cylindrical zirconia (ZrO2) ferrules to...
IEC 61755-3-2:2024 defines the dimensional limits of the optical interface that are necessary for single-mode fibre optic connectors with 2,5 mm or 1,25 mm diameter cylindrical zirconia (ZrO2) ferrules polished...
IEC 61755-3-31:2015 defines certain dimensional limits of an angled PC rectangular polyphenylene sulphide (PPS) ferrule optical interface in order to meet specific requirements for fibre-to-fibre interconnection. Ferrules made from the...
IEC 61755-3-32:2015 defines certain dimensional limits of an angled PC rectangular thermoset (TS) ferrule optical interface in order to meet specific requirements for fibre-to-fibre interconnection. Ferrules made from the material...
IEC 61755-3-6:2006+A1:20 12 defines dimensional limits and material properties of a 2,5 mm and a 1,25 mm diameter cylindrical composite ferrule optical interface to meet specific requirements for APC fibre-to-fibre...
IEC 61755-3-7:2009 defines dimensional limits and material properties of a 2,5 mm and a 1,25 mm diameter cylindrical composite ferrule optical interface to meet specific requirements for PC fibre-to-fibre interconnection.
IEC 61755-3-8:2009 defines dimensional limits and material properties of a 2,5 mm and a 1,25 mm diameter cylindrical composite ferrule optical interface to meet specific requirements for APC fibre-to-fibre interconnection.
IEC 61755-6-2: 2018 defines the dimensional limits of an optical interface for reference connectors necessary to meet specific requirements for fibre-to-fibre interconnection of non-angled polished multimode reference connectors with cylindrical...
IEC 61756-1:2019 covers general information on fibre management system interfaces. It includes the definitions and rules under which a fibre management system interface is created and it provides also criteria...
IEC 61757-1-1:2016 defines detail specifications for fibre optic sensors using one or more fibre Bragg gratings (FBG) as the sensitive element for strain measurements. Generic specifications for fibre optic sensors...
IEC 61757-1-1:2020 defines detail specifications for fibre optic sensors using one or more fibre Bragg gratings (FBG) as the sensitive element for strain measurements. Generic specifications for fibre optic sensors...
IEC 61757-1-1:2020 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61757-1-2: 2023 defines detailed specifications for distributed strain measurements with a fibre optic sensor, also known as "fibre optic distributed strain sensing". It is applicable to distributed strain sensing...
IEC 61757-1:2012 is a generic specification covering optical fibres, components and sub-assemblies as they pertain specifically to fibre optic sensing applications. It has been designed to be used as a...
IEC 61757-2-1:2021 specifies the terminology, characteristic performance parameters and related test methods of optical temperature sensors based on fibre Bragg gratings (FBG) that carry out temperature measurements in the temperature...
IEC 61757-2-2:2016 defines detail specifications for distributed temperature measurement by a fibre optic sensor, also known as fibre optic distributed temperature sensing (DTS). DTS includes the use of Raman scattering,...
IEC 61757-3-2:2022 specifies the terminology, characteristic performance parameters, related test and calculation methods, as well as specific test equipment for interrogation units used in distributed fibre optic acoustic sensing and...
IEC 61757-4-3: 2020 defines terminology, structure, and a characteristic test method of an optical current sensor using the polarimetric method. It addresses the current sensing element only and not the...
IEC 61757-5-1:2021 defines the terminology, structure, characteristics and their measurement method including the procedures, for an optical tilt sensor based on fibre Bragg gratings (FBGs) as the sensitive element.
IEC 61757-6-1:2024 defines the terminology, structure, and measurement methods of optical displacement sensors based on fibre Bragg gratings (FBGs) as the sensing element. This document also specifies the most important...
IEC 61757-7-3:2024 defines the terminology, structure, and performance characteristics of fibre optic voltage sensors using a polarimetric measurement method. The document specifies test methods and procedures for measuring key performance...
IEC 61757:2018 is a generic specification covering optical fibres, components and sub-assemblies as they pertain specifically to fibre optic sensing applications. It has been designed to be used as a...
IEC 61758-1:2008 provides general information and guidance on the subject of closures. It includes references, general closure and interface descriptions and definitions. Key words: interface standard for closures
IEC 61760-1:2006-04(en-f r) gives a reference set of process conditions and related test conditions to be used when compiling component specifications of electronic components that are intended for usage in...
IEC 61760-1:2020 defines requirements for component specifications of electronic components that are intended for usage in surface mounting technology. To this end, it specifies a reference set of process conditions...
IEC 61760-2:2007 describes the transportation and storage conditions for surface mounting devices (SMDs) that are fulfilled in order to enable trouble-free processing of surface mounting devices, both active and passive...
IEC 61760-2:2021 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61760-2:2021 specifies the transportation and storage conditions for surface mounting devices (SMDs) that are fulfilled in order to enable trouble-free processing of surface mounting devices, both active and passive.
IEC 61760-3:2010 gives a reference set of requirements, process conditions and related test conditions to be used when compiling specifications of electronic components that are intended for usage in through...
IEC 61760-3:2021 gives a reference set of requirements, process conditions and related test conditions to be used when compiling specifications of electronic components that are intended for usage in through-hole...
IEC 61760-4:2015 specifies the classification of moisture sensitive devices into moisture sensitivity levels related to soldering heat, and provisions for packaging, labelling and handling. It also extends the classification and...
IEC 61760-4:2015+A1:2018 specifies the classification of moisture sensitive devices into moisture sensitivity levels related to soldering heat, and provisions for packaging, labelling and handling. It also extends the classification and...
IEC 61770-amd.1-Ed.1.0 Amendment 1 Electric appliances connected to the water mains - Avoidance of backsiphonage and failure of hose-sets
IEC 61770:2008 provides requirements for appliances for household and similar purposes to prevent the backsiphonage of non-potable water into the water mains. It also specifies requirements for hose-sets used for...
IEC 61770:2008+A1:2015 provides requirements for appliances for household and similar purposes to prevent the backsiphonage of non-potable water into the water mains. It also specifies requirements for hose-sets used for...
IEC 61772:2009 supplements IEC 60964 and presents design requirements for the application of VDUs in main control rooms of nuclear power plants. Assists the designer in specifying VDU applications including...
IEC 61784 3-2:2007 specifies a safety communication layer (services and protocol) based on CPF 2 of IEC 61784-1, IEC 61784-2 and IEC 61158 Type 2. It identifies the principles for...
IEC 61784 3-2:2010 specifies a safety communication layer (services and protocol) based on CPF 2 of IEC 61784-1, IEC 61784-2 and IEC 61158 Type 2. It identifies the principles for...
IEC 61784 3-2:2016 specifies a safety communication layer (services and protocol) based on CPF 2 of IEC 61784-1, IEC 61784-2 and IEC 61158 Type 2. It identifies the principles for...
IEC 61784 3-3:2007 specifies a safety communication layer (services and protocol) based on CPF 3 of IEC 61784-1, IEC 61784-2 (CP 3/1, CP 3/2, CP 3/4, CP 3/5 and CP...
IEC 61784 3-6:2010 specifies a safety communication layer (services and protocol) based on CPF 6 of IEC 61784-1, IEC 61784-2 and IEC 61158 Type 8. It identifies the principles for...
IEC 61784-1-0:2023 series defines several Communication Profile Families (CPF). Each CPF specifies a set of protocol specific communication profiles (CPs) based primarily on the IEC 61158 series, to be used...
IEC 61784-1-16:2023 defines Communication Profile Family 16 (CPF 16). CPF 16 specifies a set of protocol specific communication profiles (CPs) based on the IEC 61158 series (Type 16 and Type...
IEC 61784-1-19:2023 defines Communication Profile Family 19 (CPF 19). CPF 19 specifies a set of protocol specific communication profiles (CPs) based on the IEC 61158 series (Type 24 and Type...
IEC 61784-1-1:2023 defines Communication Profile Family 1 (CPF 1). CPF 1 specifies a set of protocol specific communication profiles (CPs) based on the IEC 61158 series (Type 1, Type 5...
IEC 61784-1-22:2023 defines Communication Profile Family 22 (CPF 22). CPF 22 specifies a protocol specific communication profile (CP) based on the IEC 61158 series (Type 28) and other standards, to...
IEC 61784-1-2:2023 defines Communication Profile Family 2 (CPF 2). CPF 2 specifies a set of protocol specific communication profiles (CPs) based on the IEC 61158 series (Type 2) and other...
IEC 61784-1-3:2023 defines Communication Profile Family 3 (CPF 3). CPF 3 specifies a set of protocol specific communication profiles (CPs) based on the IEC 61158 series (Type 3 and Type...
IEC 61784-1-4:2023 defines Communication Profile Family 4 (CPF 4). CPF 4 specifies a set of protocol specific communication profiles (CPs) based on the IEC 61158 series (Type 4) and other...
IEC 61784-1-5:2023 defines Communication Profile Family 5 (CPF 5). CPF 5 specifies a set of protocol specific communication profiles (CPs) based on the IEC 61158 series (Type 7) and other...
IEC 61784-1-6:2023 defines Communication Profile Family 6 (CPF 6). CPF 6 specifies a set of protocol specific communication profiles (CPs) based on the IEC 61158 series (Type 8) and other...
IEC 61784-1-8:2023 defines Communication Profile Family 8 (CPF 8). CPF 8 specifies a set of protocol specific communication profiles (CPs) based on the IEC 61158 series (Type 18 and Type...
IEC 61784-1-9:2023 defines Communication Profile Family 9 (CPF 9). CPF 9 specifies a set of protocol specific communication profiles (CPs) based on the IEC 61158 series (Type 20) and other...
IEC 61784-1:2007 defines a set of protocol specific communication profiles based primarily on the IEC 61158 series, to be used in the design of devices involved in communications in factory...
IEC 61784-1:2010 defines a set of protocol specific communication profiles based primarily on the IEC 61158 series, to be used in the design of devices involved in communications in factory...
IEC 61784-1:2014 defines a set of protocol specific communication profiles based primarily on the IEC 61158 series, to be used in the design of devices involved in communications in factory...
IEC 61784-1:2019 defines a set of protocol specific communication profiles based primarily on the IEC 61158 series, to be used in the design of devices involved in communications in factory...
IEC 61784-2-0:2023 specifies: basic principles of performance indicators expressing RTE performance of a CP (see 5.1); how an application-dependen t class could be used to find out a suitable CP...
IEC 61784-2-10:2023 defines Communication Profile Family 10 (CPF 10). CPF 10 specifies a Real-Time Ethernet (RTE) communication profile (CP) and related network components based on the IEC 61158 series (Type...
IEC 61784-2-11:2023 defines Communication Profile Family 11 (CPF 11). CPF 11 specifies a set of Real-Time Ethernet (RTE) communication profiles (CPs) and related network components based on the IEC 61158...
IEC 61784-2-12:2023 defines Communication Profile Family 12 (CPF 12). CPF 12 specifies a set of Real-Time Ethernet (RTE) communication profiles (CPs) and related network components based on the IEC 61158...
IEC 61784-2-13:2023 defines Communication Profile Family 13 (CPF 13). CPF 13 specifies a Real-Time Ethernet (RTE) communication profile (CP) and related network components based on the IEC 61158 series (Type...
IEC 61784-2-14:2023 defines Communication Profile Family 14 (CPF 14). CPF 14 specifies a set of Real-Time Ethernet (RTE) communication profiles (CPs) and related network components based on the IEC 61158...
IEC 61784-2-15:2023 defines Communication Profile Family 15 (CPF 15). CPF 15 specifies a set of Real-Time Ethernet (RTE) communication profiles (CPs) and related network components based on the IEC 61158...
IEC 61784-2-16:2023 defines extensions of Communication Profile Family 16 (CPF 16) for Real-Time Ethernet (RTE). CPF 16 specifies a Real-Time Ethernet (RTE) communication profile (CP) and related network components based...
IEC 61784-2-17:2023 defines Communication Profile Family 17 (CPF 17). CPF 17 specifies a Real-Time Ethernet (RTE) communication profile (CP) and related network components based on the IEC 61158 series (Type...
IEC 61784-2-18:2023 defines Communication Profile Family 18 (CPF 18). CPF 18 specifies a set of Real-Time Ethernet (RTE) communication profiles (CPs) and related network components based on the IEC 61158...
IEC 61784-2-19:2023 defines extensions of Communication Profile Family 19 (CPF 19) for Real-Time Ethernet (RTE). CPF 19 specifies a Real-Time Ethernet (RTE) communication profile (CP) and related network components based...
IEC 61784-2-20:2023 defines Communication Profile Family 20 (CPF 20). CPF 20 specifies a set of Real-Time Ethernet (RTE) communication profiles (CPs) and related network components based on the IEC 61158...
IEC 61784-2-21:2023 defines Communication Profile Family 21 (CPF 21). CPF 21 specifies a Real-Time Ethernet (RTE) communication profile (CP) and related network components based on the IEC 61158 series (Type...
IEC 61784-2-2:2023 defines extensions of Communication Profile Family 2 (CPF 2) for Real-Time Ethernet (RTE). CPF 2 specifies a set of Real-Time Ethernet (RTE) communication profiles (CPs) and related network...
IEC 61784-2-3:2023 defines extensions of Communication Profile Family 3 (CPF 3) for Real-Time Ethernet (RTE). CPF 3 specifies a set of Real-Time Ethernet (RTE) communication profiles (CPs) and related network...
IEC 61784-2-4:2023 defines extensions of Communication Profile Family 4 (CPF 4) for Real-Time Ethernet (RTE). CPF 4 specifies a Real-Time Ethernet (RTE) communication profile (CP) and related network components based...
IEC 61784-2-6:2023 defines extensions of Communication Profile Family 6 (CPF 6) for Real-Time Ethernet (RTE). CPF 6 specifies a set of Real-Time Ethernet (RTE) communication profiles (CPs) and related network...
IEC 61784-2-8:2023 defines extensions of Communication Profile Family 8 (CPF 8) for Real-Time Ethernet (RTE). CPF 8 specifies a set of Real-Time Ethernet (RTE) communication profiles (CPs) and related network...
IEC 61784-2:2007 specifies the performance indicators supporting classification schemes for Real-Time Ethernet (RTE) requirements; the profiles and related network components based on ISO/IEC 8802-3, IEC 61158 series, and IEC 61784-1...
IEC 61784-2:2010 specifies performance indicators supporting classification schemes for Real-Time Ethernet (RTE) requirements; profiles and related network components based on ISO/IEC 8802-3, IEC 61158 series, and IEC 61784-1; RTE solutions...
IEC 61784-2:2014 specifies the performance indicators supporting classification schemes for Real-Time Ethernet (RTE) requirements; the profiles and related network components based on ISO/IEC 8802-3 or IEEE 802.3, IEC 61158 series,...
IEC 61784-2:2019 specifies the performance indicators supporting classification schemes for Real-Time Ethernet (RTE) requirements; the profiles and related network components based on ISO/IEC 8802-3 or IEEE 802.3, IEC 61158 series,...
IEC 61784-3-12:2010 specifies a safety communication layer (services and protocol) based on CPF 12 of IEC 61784-2 and IEC 61158 Type 12. It identifies the principles for functional safety communications...
IEC 61784-3-12:2010+A1:2 019 specifies a safety communication layer (services and protocol) based on CPF 12 of IEC 61784-2 and IEC 61158 Type 12. It identifies the principles for functional safety...
IEC 61784-3-13:2010 specifies a safety communication layer (services and protocol) based on CPF 13 of IEC 61784-2 and IEC 61158 Type 13. It identifies the principles for functional safety communications...
IEC 61784-3-13:2016 specifies a safety communication layer (services and protocol) based on CPF 13 of IEC 61784-2 and IEC 61158 Type 13. It identifies the principles for functional safety communications...
IEC 61784-3-13:2021 specifies a safety communication layer (services and protocol) based on CPF 13 of IEC 61784 2 and IEC 61158 Type 13. It identifies the principles for functional safety...
IEC 61784-3-14:2010 specifies a safety communication layer (services and protocol) based on CPF 14 of IEC 61784-2 and IEC 61158 Type 14. It identifies the principles for functional safety communications...
IEC 61784-3-17:2016 specifies a safety communication layer (services and protocol) based on CPF 17 of IEC 61784-2 (CP 17/1) and IEC 61158 Type 21. It identifies the principles for functional...
IEC 61784-3-18:2011 specifies a safety communication layer (services and protocol) based on CPF 18 of IEC 61784-2 and IEC 61158 Type 22. It identifies the principles for functional safety communications...
IEC 61784-3-18:2011+A1:2 016 specifies a safety communication layer (services and protocol) based on CPF 18 of IEC 61784-2 and IEC 61158 Type 22. It identifies the principles for functional safety...
IEC 61784-3-18:2011+A1:2 016+A2:2021 specifies a safety communication layer (services and protocol) based on CPF 18 of IEC 61784-2 and IEC 61158 Type 22. It identifies the principles for functional safety...
IEC 61784-3-19:2024 specifies a safety communication layer (services and protocol) based on IEC 61784‑1-19, IEC 61784-2-19 and the IEC 61158 series (Type 24 and Type 27). It identifies the principles...
IEC 61784-3-1:2007 specifies a safety communication layer (services and protocol) based on CPF 1 of IEC 61784-1 and IEC 61158 Type 1 and 9. It identifies the principles for functional...
IEC 61784-3-1:2010 specifies a safety communication layer (services and protocol) based on CPF 1 of IEC 61784-1 and IEC 61158 Types 1 and 9. It identifies the principles for functional...
IEC 61784-3-2:2021 specifies a safety communication layer (services and protocol) based on CPF 2 of IEC 61784 1, IEC 61784 2 and IEC 61158 Type 2. It identifies the principles...
IEC 61784-3-3:2010 specifies a safety communication layer (services and protocol) based on CPF 3 of IEC 61784-1, IEC 61784-2 (CP 3/1, CP 3/2, CP 3/4, CP 3/5 and CP 3/6)...
IEC 61784-3-3:2016 specifies a safety communication layer (services and protocol) based on CPF 3 of IEC 61784-1, IEC 61784-2 (CP 3/1, CP 3/2, CP 3/4, CP 3/5 and CP 3/6)...
IEC 61784-3-3:2021 specifies a safety communication layer (services and protocol) based on CPF 3 of IEC 61784-1, IEC 61784-2 (CP 3/1, CP 3/2, CP 3/4, CP 3/5 and CP 3/6)...
IEC 61784-3-6:2007 specifies a safety communication layer (services and protocol) based on CPF 6 of IEC 61784-1, IEC 61784-2 and IEC 61158 Type 8. It identifies the principles for functional...
IEC 61784-3-8:2010(E) specifies a safety communication layer (services and protocol) based on CPF 8 of IEC 61784-1 and IEC 61158 Type 18. It identifies the principles for functional safety communications...
IEC 61784-3-8:2016 specifies a safety communication layer (services and protocol) based on CPF 8 of IEC 61784-1, IEC 61784-2 and IEC 61158 Type 18 and Type 23. It identifies the...
IEC 61784-3-8:2021 specifies a safety communication layer (services and protocol) based on CPF 8 of IEC 61784 1, IEC 61784-2 and IEC 61158 Type 18 and Type 23. It identifies...
IEC 61784-3:2007 explains some common principles than can be used in the transmission of safety-relevant messages among participants within a distributed network using fieldbus technology in accordance with the requirements...
IEC 61784-3:2010 explains some common principles than can be used in the transmission of safety-relevant messages among participants within a distributed network using fieldbus technology in accordance with the requirements...
IEC 61784-3:2016 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61784-3:2016 series explains some common principles that can be used in the transmission of safety-relevant messages among participants within a distributed network which use fieldbus technology in accordance with...
IEC 61784-3:2016+A1:2017 series explains some common principles that can be used in the transmission of safety-relevant messages among participants within a distributed network which use fieldbus technology in accordance with...
IEC 61784-3:2021 explains some common principles that can be used in the transmission of safety-relevant messages among participants within a distributed network which use fieldbus technology in accordance with the...
IEC 61784-3:2021+AMD1:20 24 CSV explains some common principles that can be used in the transmission of safety-relevant messages among participants within a distributed network which use fieldbus technology in accordance...
IEC 61784-5-10:2007 is one document of a series produced to facilitate the use of communication networks in industrial control systems. It specifies the installation profile for CPF 10 (Vnet/IPTM). The...
IEC 61784-5-10:2010 specifies the installation profiles for CPF 10 (Vnet/IP ).The installation profiles are specified in the annex. This second edition cancels and replaces the first edition published in 2007.
IEC 61784-5-10:2010+A1:2 015 specifies the installation profiles for CPF 10 (Vnet/IP). The installation profiles are specified in the annex. This second edition cancels and replaces the first edition published in...
IEC 61784-5-11:2007 specifies the installation profile for CPF 11 (TCnet). The installation profile is specified in the annex. This annex is read in conjunction with IEC 61918:2007. This bilingual version...
IEC 61784-5-11:2010 specifies the installation profiles for CPF 11 (TCnet). The installation profiles are specified in the annex. This annex is read in conjunction with IEC 61918:2010. This second edition...
IEC 61784-5-11:2013 specifies the installation profiles for CPF 11 (TCnet). Each CP installation profile is specified in a separate part of this standard. The IEC 61784 series is produced to...
IEC 61784-5-12:2010 specifies the installation profiles for CPF 12 (EtherCAT). The installation profiles are specified in the annex. This annex is read in conjunction with IEC 61918:2010. This bilingual version...
IEC 61784-5-12:2010+A1:2 015 specifies the installation profiles for CPF 12 (EtherCAT). The installation profiles are specified in the annex. This bilingual version (2012-02) corresponds to the monolingual English version, published...
IEC 61784-5-12:2018 specifies the installation profiles for CPF 12 (EtherCAT™) . This deliverable contains a number of related files covering the communication profiles to be used in conjunction with IEC...
IEC 61784-5-12:2024 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61784-5-12:2024 specifies the installation profile for CPF 12 (EtherCAT™). The installation profile is specified in Annex A. This annex is read in conjunction with IEC 61918:2018, IEC 61918:2018/AMD1:2022 and...
IEC 61784-5-13:2013 specifies installation profiles for CPF 13 (Ethernet POWERLINK). Each CP installation profile is specified in a separate part of this series of standards. The IEC 61784 series is...
IEC 61784-5-14:2010 specifies the installation profiles for CPF 14 (EPA). The installation profiles are specified in the annex. This annex is read in conjunction with IEC 61918:2010. This bilingual version...
IEC 61784-5-14:2013 specifies the installation profiles for CPF 14 (EPA). Each CP installation profile is specified in a separate part of this standard. The IEC 61784 series is produced to...
IEC 61784-5-15:2010 specifies the installation profiles for CPF 15/1 (MODBUS -TCP) and CPF 15/2 (RTPS).The installation profiles are specified in the annex. This annex is read in conjunction with IEC...
IEC 61784-5-15:2010+A1:2 015 specifies the installation profiles for CPF 15/1 (MODBUS -TCP) and CPF 15/2 (RTPS).The installation profiles are specified in the annex. This bilingual version (2012-02) corresponds to the...
IEC 61784-5-16:2013 specifies installation profiles for CPF 16 (SERCOS). Each CP installation profile is specified in a separate part of this series of standards. The IEC 61784 series is produced...
IEC 61784-5-17:2013 specifies installation profiles for CPF 17 (RAPIEnet). Each CP installation profile is specified in a separate part of this series of standards. The IEC 61784 series is produced...
IEC 61784-5-18:2013 specifies installation profiles for CPF 18 (SafetyNET p). Each CP installation profile is specified in a separate part of this series of standards. The IEC 61784 series is...
IEC 61784-5-18:2018 specifies the installation profiles for CPF 18 (SafetyNETp). This contribution contains a number of related files covering the communication profiles to be used with IEC 61918. This installation...
IEC 61784-5-19:2013 specifies installation profiles for CPF 19 (MECHATROLINK). Each CP installation profile is specified in a separate part of this series of standards. The IEC 61784 series is produced...
IEC 61784-5-19:2024 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61784-5-19:2024 specifies the installation profile for CPF 19 (MECHATROLINKTM[1]). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2018, IEC 61918:2018/AMD1:2022 and...
IEC 61784-5-1:2013 specifies installation profiles for CPF 1 (FOUNDATION Fieldbus). Each CP installation profile is specified in a separate part of this series of standards. The IEC 61784 series is...
IEC 61784-5-20:2018 specifies the installation profiles for CPF 20 (ADS-net). This contribution contains a number of related files covering the communication profiles to be used with IEC 61918. This installation...
IEC 61784-5-21:2018 specifies the installation profiles for CPF 21 (FL-net). This contribution contains a number of related files covering the communication profiles to be used with IEC 61918. This installation...
IEC 61784-5-21:2018+AMD1 :2024 CSV specifies the installation profiles for CPF 21 (FL-net). This contribution contains a number of related files covering the communication profiles to be used with IEC 61918.
IEC 61784-5-22:2024 specifies the installation profile for CPF 22 (AUTBUSTM [1]). The installation profile is specified in Annex A. This annex is read in conjunction with IEC 61918:2018, IEC 61918:2018/AMD1:2022...
IEC 61784-5-2:2010 specifies the installation profiles for CPF 2 (CIPTM1). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2010. This second edition...
IEC 61784-5-2:2013 specifies the installation profiles for CPF 2 (CIPTM1). Each CP installation profile is specified in a separate annex of this standard. The IEC 61784 series is produced to...
IEC 61784-5-2:2018 specifies the installation profiles for CPF 2 (CIP™ ). This contribution contains a number of related files covering the communication profiles to be used in conjunction with IEC...
IEC 61784-5-2:2018+AMD1: 2024 CSV specifies the installation profiles for CPF 2 (CIP™ ). This contribution contains a number of related files covering the communication profiles to be used in conjunction...
IEC 61784-5-3:2007 specifies the installation profiles for CPF 3 (PROFIBUS/PROFINET). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2007. This bilingual version...
IEC 61784-5-3:2010(E) specifies the installation profiles for CPF 3 (PROFIBUS/PROFINET). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2010. This second edition...
IEC 61784-5-3:2013 specifies the installation profiles for CPF 3 (PROFIBUS/PROFINET). Each CP installation profile is specified in a separate annex of this standard. The IEC 61784 series is produced to...
IEC 61784-5-3:2018 specifies the installation profiles for CPF 3 (PROFIBUS/PROFINET). This contribution contains a number of related files covering the communication profiles to be used in conjunction with IEC 61918.
IEC 61784-5-3:2018+AMD1. 2024 CSV specifies the installation profiles for CPF 3 (PROFIBUS/PROFINET). This contribution contains a number of related files covering the communication profiles to be used in conjunction with...
IEC 61784-5-4:2010 specifies the installation profiles for CPF 4 (P-NET). The installation profiles are specified in the annexes. This bilingual version (2012-02) corresponds to the monolingual English version, published in...
IEC 61784-5-4:2010+A1:20 15 specifies the installation profiles for CPF 4 (P-NET). The installation profiles are specified in the annexes. This bilingual version (2012-02) corresponds to the monolingual English version, published...
IEC 61784-5-6:2007 specifies the installation profiles for the media specified in CPF 6 (INTERBUS). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC...
IEC 61784-5-6:2010 specifies the installation profiles for CPF 6 (INTERBUS). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2010. This second edition...
IEC 61784-5-6:2013 specifies the installation profiles for CPF 6 (INTERBUS). Each CP installation profile is specified in a separate annex of this standard. The IEC 61784 series is produced to...
IEC 61784-5-6:2018 specifies the installation profiles for CPF 6 (INTERBUS). This contribution contains a number of related files covering the communication profiles to be used in conjunction with IEC 61918.
IEC 61784-5-6:2024 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61784-5-6:2024 specifies the installation profiles for CPF 6 (INTERBUSTM)[1]. The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2018, IEC 61918:2018/AMD1:2022 and...
IEC 61784-5-8:2013 specifies installation profiles for CPF 8 (CC-Link). Each CP installation profile is specified in a separate part of this series of standards. The IEC 61784 series is produced...
IEC 61784-5-8:2018 specifies the installation profiles for CPF 8 (CC-Link ). This deliverable contains a number of related files covering the communication profiles to be used with IEC 61918. This...
IEC 61784-5-8:2024 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61784-5-8:2024 specifies the installation profiles for CPF 8 (CC-LinkTM[1]). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2018, IEC 61918:2018/AMD1:2022 and...
IEC 61786-1:2013 provides guidance for measuring instruments used to measure the field strength of quasi-static magnetic and electric fields that have a frequency content in the range 1 Hz to...
IEC 61786-1:2013+AMD1:20 24 CSV provides guidance for measuring instruments used to measure the field strength of quasi-static magnetic and electric fields that have a frequency content in the range 1...
IEC 61786-2:2014 provides requirements for the measurement of quasi-static magnetic and electric fields that have a frequency content in the range 1 Hz to 100 kHz, and DC magnetic fields,...
IEC 61788-11:2011 covers a test method for the determination of the residual resistance ratio (RRR) of Nb3Sn composite superconductors. This method is intended for use with superconductor specimens...
IEC 61788-12:2013 describes a test method for determining the copper to non-copper volume ratio of Cu/Nb3Sn wires. The test method given hereunder is applicable to Nb3Sn...
IEC 61788-13:2012 describes considerations for the measurement of hysteretic loss in Cu/Nb-Ti multifilamentary composites using DC- or low-ramp-rate magnetometry. This international standard specifies a method of the measurement of hysteretic...
IEC 61788-14:2010 provides general requirements for characteristic tests of conventional as well as superconducting current leads to be used for powering superconducting equipment. Current leads are indispensable components of superconducting...
IEC 61788-15:2011 describes measurements of the intrinsic surface impedance (Zs) of HTS films at microwave frequencies by a modified two-resonance mode dielectric resonator method. The object of measurement...
IEC 61788-16:2013 involves describing the standard measurement method of power-dependent surface resistance of superconductors at microwave frequencies by the sapphire resonator method. The measuring item is the power dependence of...
IEC 61788-17:2013 describes the measurements of the local critical current density (Jc) and its distribution in large-area high-temperature superconducting (HTS) films by an inductive method using third-harmonic voltages. The most...
IEC 61788-17:2021 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61788-17:2021 specifies the measurements of the local critical current density (Jc) and its distribution in large-area high-temperature superconducting (HTS) films by an inductive method using third-harmonic voltages. The most...
IEC 61788-18:2013 specifies a test method detailing the tensile test procedures to be carried out on Ag/Bi-2223 and Ag/Bi-2212 superconductive composite wires at room temperature. This test is used to...
IEC 61788-19:2013 covers a test method detailing the tensile test procedures to be carried out on reacted Cu/Nb3Sn composite superconducting wires at room temperature. The object of this test is...
IEC 61788-21:2015 specifies the test methods used for validating the mechanical, electrical, and superconducting properties of practical SC wires.
IEC 61788-22-1:2017 describes general items concerning the specifications for superconducting sensors and detectors, which are the basis for specifications given in other parts of IEC 61788 for various types of...
IEC 61788-22-2:2021 is applicable to high-Tc Josephson junctions. It specifies terms, definitions, symbols and the measurement and estimation method for normal state resistance (Rn) and intrinsic critical current (Ici), based...
IEC 61788-22-3:2022 is applicable to the measurement of the dark count rate (DCR, RD) of superconductor strip photon detectors (SSPDs). It specifies terms, definitions, symbols and the measurement method of...
IEC 61788-23:2018 addresses a test method for the determination of the residual resistance ratio (RRR) of cavity-grade niobium. The test method should be valid for specimens with rectangular or round...
IEC 61788-23:2021 addresses a test method for the determination of the residual resistance ratio (RRR), rRRR, of cavity-grade niobium. This method is intended for high-purity niobium grades with 150 <
IEC 61788-23:2021 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61788-23:2024 addresses a test method for the determination of the residual resistance ratio (RRR), rRRR, of cavity-grade niobium. This method is intended for high-purity niobium grades with 150 <
IEC 61788-23:2024 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61788-24:2018 describes a test method for determining the retained critical current after double bending at room temperature of short and straight Ag- and/or Ag alloy-sheathed Bi-2223 superconducting wires that...
IEC 61788-25:2018 specifies the test method and procedures for testing tensile mechanical properties of REBCO superconductive composite tapes at room temperature. This test is used to measure the modulus of...
IEC 61788-26:2020 specifies a test method for determining the DC critical current of short RE (rare earth)-Ba-Cu-O (REBCO) composite superconductor specimens that have a shape of straight flat tape. This...
IEC 61788-4:2011 covers a test method for the determination of the residual resistance ratio (RRR) of composite superconductors comprised of Nb-Ti filaments and Cu, Cu-Ni or Cu/Cu-Ni matrix. This method...
IEC 61788-4:2016 specifies a test method for the determination of the residual resistance ratio (RRR) of Nb-Ti and Nb3Sn composite superconductors with Cu, Cu-Ni, Cu/Cu-Ni and Al matrix.
IEC 61788-4:2020 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61788-4:2020 specifies a test method for the determination of the residual resistance ratio (RRR) of Nb-Ti and Nb3Sn composite superconductors with Cu, Cu-Ni, Cu/Cu-Ni and Al matrix in a...
IEC 61788-5:2013 covers a test method for the determination of copper to superconductor volume ratio of Cu/Nb-Ti composite superconducting wires. This test method and the alternate method in Annex are...
IEC 61788-6:2011 covers a test method detailing the tensile test procedures to be carried out on Cu/Nb-Ti superconductive composite wires at room temperature. This test is used to measure modulus...
IEC 61788-7:2006 describes measurement of the surface resistance of superconductors at microwave frequencies by the standard two-resonator method. The object of measurement is the temperature dependence of Rs at the...
IEC 61788-7:2020 describes measurement of the surface resistance (Rs) of superconductors at microwave frequencies by the standard two-resonator method. The object of measurement is the temperature dependence of Rs at...
IEC 61788-7:2020 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61788-8:2010 specifies the measurement method of total AC losses by the pickup coil method in composite superconducting wires exposed to a transverse alternating magnetic field. The losses may contain...
IEC 61800-1:2021 applies to adjustable speed electric DC power drive systems, which include semiconductor power conversion and the means for their control, protection, monitoring, measurement and the DC motors. It...
IEC 61800-2:2015 applies to adjustable speed electric a.c. power drive systems, which include semiconductor power conversion and the means for their control, protection, monitoring, measurement and the a.c. motors. It...
IEC 61800-2:2021 applies to adjustable speed electric AC power drive systems, which include semiconductor power conversion and the means for their control, protection, monitoring, measurement and the AC motor...
IEC 61800-3:2004+A1:2011 specifies electromagnetic compatibility (EMC) requirements for power drive systems (PDSs). A PDS is defined in 3.1. These are adjustable speed a.c. or d.c. motor drives. Requirements are stated...
IEC 61800-3:2017 is also available as IEC 61800-3:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61800-3:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61800-3:2022 specifies electromagnetic compatibility (EMC) requirements for adjustable speed power drive systems (PDSs) and machine tools (MTs). A PDS is an AC or DC motor drive including an electronic...
IEC 61800-5-1:2007 It specifies requirements for adjustable speed power drive systems, or their elements, with respect to electrical, thermal and energy safety considerations. It does not cover the driven equipment...
IEC 61800-5-1:2007+A1:20 16 It specifies requirements for adjustable speed power drive systems, or their elements, with respect to electrical, thermal and energy safety considerations. It does not cover the driven...
IEC 61800-5-1:2022 specifies requirements for adjustable speed electrical power drive systems (PDS) or their elements, with respect to electrical, thermal, fire, mechanical, energy and other relevant hazards. It does not...
IEC 61800-5-2:2007 specifies requirements and makes recommendations for the design and development, integration and validation of PDS(SR)s in terms of their functional safety considerations. It applies to adjustable speed electric...
IEC 61800-5-2:2016 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61800-5-2:2016 specifies requirements and makes recommendations for the design and development, integration and validation of safety related power drive systems (PDS(SR)) in terms of their functional safety considerations. It...
IEC 61800-5-3:2021, which is a product standard, specifies requirements and makes recommendations for the design and development, integration and validation of safety-related encoder (Encoder(SR)) in terms of their...
IEC 61800-7-1:2007 specifies a generic interface between power drive system(s) (PDS) and the application control program in a controller. The generic PDS interface is not specific to any particular communication...
IEC 61800-7-1:2015 specifies a generic interface between power drive system(s) (PDS) and the application control program in a controller. The generic PDS interface is not specific to any particular communication...
IEC 61800-7-201:2007 specifies profiles for Power Drive Systems (PDS) and their mapping to existing communication systems by use of a generic interface model as well as profile type 1 for...
IEC 61800-7-201:2015 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61800-7-201:2015 specifies profile type 1 for power drive systems (PDS). Profile type 1 can be mapped onto different network technologies. This edition includes the following significant technical changes with...
IEC 61800-7-202:2007 specifies profiles for Power Drive Systems (PDS) and their mapping to existing communication systems by use of a generic interface model. It also specifies profile type 2 (CIP...
IEC 61800-7-202:2015 specifies profile type 2 (CIP MotionTM) for Power Drive Systems (PDS). Profile type 2 can be mapped onto different communication network technologies. This edition includes the following significant...
IEC 61800-7-203:2007 specifies profiles for Power Drive Systems (PDS) and their mapping to existing communication systems by use of a generic interface model as well as specifies profile type 3...
IEC 61800-7-203:2015 specifies profile type 3 for power drive systems (PDS). Profile type 3 can be mapped onto different communication network technologies. This edition includes the following significant technical changes...
IEC 61800-7-204:2007 specifies profiles for Power Drive Systems (PDS) and their mapping to existing communication systems by use of a generic interface model as well as profile type 4 for...
IEC 61800-7-204:2015 specifies profile type 4 for power drive systems (PDS). Profile type 4 can be mapped onto different communication network technologies. This edition includes the following significant technical change...
IEC 61800-7-301:2007 specifies profiles for Power Drive Systems (PDS) and their mapping to existing communication systems by use of a generic interface model. It also specifies the mapping of the...
IEC 61800-7-301:2015 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61800-7-301:2015 specifies the mapping of the profile type 1 (CiA 402) specified in IEC 61800-7-201 onto different network technologies. This edition includes the following significant technical changes with respect...
IEC 61800-7-302:2007 specifies profiles for Power Drive Systems (PDS) and their mapping to existing communication systems by use of a generic interface model. It also specifies the mapping of the...
IEC 61800-7-302:2015 specifies the mapping of the profile type 2 (CIP MotionTM) specified in IEC 61800-7-202 onto different network technologies. This edition includes the following significant technical changes with respect...
IEC 61800-7-303:2007 specifies profiles for Power Drive Systems (PDS) and their mapping to existing communication systems by use of a generic interface model. It also specifies how the profile type...
IEC 61800-7-303:2015 specifies the mapping of the profile type 3 (PROFIdrive) specified in IEC 61800-7-203 onto different network technologies. This edition includes the following significant technical changes with respect to...
IEC 61800-7-304:2007 specifies profiles for Power Drive Systems (PDS) and their mapping to existing communication systems by use of a generic interface model. It also specifies the mapping of the...
IEC 61800-7-304:2015 specifies the mapping of the profile type 4 (SERCOS) specified in IEC 61800-7-204 onto different network technologies. This edition includes the following significant technical change with respect to...
IEC 61800-9-1:2017 specifies the general methodology to energy efficiency standardization for any extended product by using the guidance of the extended product approach (EPA). This document specifies the methodology of...
IEC 61800-9-2:2017 specifies energy efficiency indicators of power electronics (complete drive modules, CDM), power drive systems (PDS) and motor starters, all used for motor driven equipment. It specifies the methodology...
IEC 61800-9-2:2023 specifies energy efficiency indicators of power electronics (complete drive modules (CDM), input or output sub drive modules (SDM), power drive systems (PDS) and motor starters, all used for...
IEC 61803:1999+A1:2010 applies to all line-commutated high-voltage direct current (HVDC) converter stations used for power exchange in utility systems. This standard presumes the use of 12-pulse thyristor converters but can,...
IEC 61803:1999+A1:2010+A 2:2016 applies to all line-commutated high-voltage direct current (HVDC) converter stations used for power exchange in utility systems. This standard presumes the use of 12-pulse thyristor converters but...
IEC 61803:2020 applies to all line-commutated high-voltage direct current (HVDC) converter stations used for power exchange (power transmission or back-to-back installation) in utility systems. This document presumes the use of...
IEC 61803:2020 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy...
IEC 61804-2:2006 Specifies FB (Function Bloks) by using the result of harmonization work as regards several elements: - the device model which defines the components of an IEC 61804-2 conformant...
IEC 61804-2:2018 specifies FB (function blocks) by using the result of a harmonization work as regards several elements. a) The device model which defines the components of an IEC 61804-2...
IEC 61804-3:2006 specifies the Electronic Device Description Language (EDDL) technology, which enables the integration of real product details using the tools of the engineering life cycle. It specifies EDDL as...
IEC 61804-3:2010 specifies the Electronic Device Description Language (EDDL) technology, which enables the integration of real product details using the tools of the engineering life cycle. It specifies EDDL as...
IEC 61804-3:2015 specifies the Electronic Device Description Language (EDDL) technology, which enables the integration of real product details using the tools of the engineering life cycle. It specifies EDDL as...
IEC 61804-3:2020 specifies the electronic device description language (EDDL) technology, which enables the integration of real product details using the tools of the engineering life cycle. This document specifies EDDL...
IEC 61804-4:2015 specifies EDD interpretation for EDD applications and EDDs to support EDD interoperability. This document is intended to ensure that field device developers use the EDDL constructs consistently and...
IEC 61804-4:2020 specifies EDD interpretation for EDD applications and EDDs to support EDD interoperability. This document is intended to ensure that field device developers use the EDDL constructs consistently and...
IEC 61804-5:2015 specifies the EDDL Builtin library and provides the profiles of the various fieldbuses.
IEC 61804-5:2020 specifies the EDDL builtin library and provides the profiles of the various fieldbuses. This second edition cancels and replaces the first edition published in 2015. This edition constitutes...
IEC 61810-10:2019, with functional and safety aspects, applies to electromechanical elementary relays (non-specified time all-or-nothing relays) with high capability requirements like breaking or short circuit capabilities and similar for incorporation...
IEC 61810-1:2008 Applies to electromechanical elementary relays (non-specified time all-or-nothing relays) for incorporation into equipment. Defines the basic functional requirements and safety-related aspects for applications in all areas of electrical...
IEC 61810-1:2015 applies to electromechanical elementary relays (non-specified time all-or-nothing relays) for incorporation into low voltage equipment (circuits up to 1 000 V alternate current or 1 500 V direct...
IEC 61810-2-1:2011 specifies reliability test procedures for electromechanical elementary relays when enhanced requirements for the verification of reliability apply. Particular provisions are given for relays incorporated in safety-related control systems...
IEC 61810-2-1:2017 specifies reliability test procedures for electromechanical elementary relays when enhanced requirements for the verification of reliability apply. Particular provisions are given for relays incorporated in safety-related control systems...
IEC 61810-2:2011 covers test conditions and provisions for the evaluation of endurance tests using appropriate statistical methods to obtain reliability characteristics for relays. The main changes with respect to the...
IEC 61810-2:2017 covers test conditions and provisions for the evaluation of endurance tests using appropriate statistical methods to obtain reliability characteristics for relays. This document applies to electromechanical elementary relays...
IEC 61810-3:2015 specifies special requirements and tests for elementary relays with forcibly guided contacts, also known as mechanically linked contacts. These special requirements apply in addition to the general requirements...
IEC 61810-4:2020 applies to electromechanical elementary relays with reed switches (reed contacts) incorporated into general control circuits. It defines the basic functional and safety requirements in all areas of electrical...
IEC 61810-7:2006 Lays down the test and measurement procedures for electromechanical elementary relays. Covers basic considerations which are common to all types of electromechanical elementary relays. Supplementary requirements may be...
IEC 61811-10:2002 is based on the basic relay standard IEC 61810-1 as well as on the generic specification IEC 61811-1 and selects from IEC 61810-7 the appropriate test and measurement...
is applicable to Function Blocks (FB) for process control and specifies the Electronic Device Description Language (EDDL), specifies FB by using the result of harmonization work as regards several elements.
Is applicable to the testing procedures for foundations of overhead line structures. The contents of the corrigendum of March 1997 have been included in this copy.
It specifies the installation profiles for CPF 2 (CIP). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2007.
Provides guidance for measuring the values of magnetic and electric fields with regard to exposure of human beings. The frequency range spans 15 Hz to 9 kHz. The standard covers...
Provides the minimum requirements and severities which a fibre optic isolator shall satisfy in order to be categorised as meeting the requirements of isolator devices used in uncontrolled environments. The...
Specifies a test method for the determination of the trapped field (trapped flux density) of bulk high temperature superconductors. This International Standard is applicable to large grain bulk oxide superconductors...
Specifies a test method for the resistive determination of the critical temperature of composite superconductors for industrial use. The composite superconductors covered in this standard include Cu/Nb-Ti, Cu/Cu-Ni/Nb-Ti and Cu-Ni/Nb-Ti...
specifies electromagnetic compatibility (EMC) requirements for power drive systems (PDSs). A PDS is defined in 3.1. These are adjustable speed a.c. or d.c. motor drives. Requirements are stated for PDSs...
Specifies EMC requirements for adjustable speed a.c. or d.c. motor drives connected to mains supplies up to 1000v a.c.. Defines limits and test methods
Specifies general requirements for construction and testing and describes the test methods that apply to portable, transportable and fixed apparatus for the detection and measurement of flammable gas or vapour...
specifies requirements for adjustable speed power drive systems, or their elements, with respect to electrical, thermal and energy safety considerations. It does not cover the driven equipment except for interface...
Specifies requirements for group I (as defined in part 1) portable, transportable and fixed apparatus for the detection and measurement of methane concentrations in mine air. The apparatus, or parts...
Specifies requirements for group II (as defined in part 1) portable, transportable and fixed apparatus for the detectino and measurement of combustible gas or vapour concentrations with air. The apparatus,...
Specifies requirements for group II (as defined in part 1) portable, transportable and fixed apparatus for the detection and measurement of combustible gas or vapour concentrations with air. The apparatus,...
Specifies requirements for the connection of appliances to the water mains to prevent backsiphonage of non-potable water into the water mains and flooding due to failure of hose-sets. Appliances include...
Specifies tests and requirements for portable sealed alakline secondary cells and batteries (other than button) for their safe operation under intended use and reasonably foreseable misuse.
Specifies tests and requirements for sealed nickel-metal hydride button rechargeable single cells, suitable for use in any orientation.
Specifies the general requirements for the insulation coordination of electromechanical non-specified time all-or-nothing relays; it is based on the basic safety standard for insulation coordination IEC 60664-1.
Specifies the main dimensions of coil formers for transformers and inductors, using a square stack of the laminations inserted in the coil formers.
Specifies the measurement method of total AC losses by the pickup coil method in Cu/Nb-Ti composite superconducting wires exposed to a transverse alternating magnetic field. The losses may contain both...
Specifies the minimum initialisation test and measurement requirements and severities for a branching device. The requirements cover balanced non-connectorised single-mode 1xN and 2xN non-wavelength-selec tive branching devices (N is the...
Specifies verification and validation procedures for the design of t he control-room system of nuclear power plants and gives verificatio n and validation criteria for the assignment of functions and...
Standard
States basic requirements for electromechanical non-specified time all-or-nothing relays. Comprises indications and explanations necessary for the understanding of the relevant basic characteristics of such relays.
States, for electromechanical all-or-nothing relays, special terms and definitions used, and test and measurement procedures.
Supplements IEC 60964 and presents design requirements for the application of VDUs in main control rooms of nuclear power plants.
This part of IEC 61753 contains the minimum initial test and measurement requirements and severities which a fibre optic C-band/L-band WDM device shall satisfy in order to be categorised as...
This part of IEC 61753 contains the minimum initial test and measurement requirements and severities which a fibre optic pigtailed 980/1 550 nm WWDM device must satisfy in order to...
This part of IEC 61753 contains the minimum test and measurement requirements and severities which a fibre optic circulator should satisfy in order to be categorized as meeting the requirements...
This part of IEC 61753 contains the minimum test and measurement requirements and severities which a fibre optic isolator must satisfy in order to be categorized as meeting the requirements...
This part of IEC 61753 contains the minimum test and measurement severities which a specific product must satisfy in order to be categorised as meeting the IEC standard, Category C...
This part of IEC 61753 contains the minimum test and measurement severities which a specific product must satisfy in order to be categorised as meeting the IEC standard, Category U...
This part of IEC 61754 defines the standard interface dimensions for the type F-SMA family of connectors.
This part of IEC 61755 covers singlemode optical interfaces. It includes references, document structure details, definitions, preferred grades and the rules under which an optical interface is created. This standard...
This part of IEC 61755 defines a set of prescribed conditions that must be maintained in order to satisfy the requirements of attenuation and return loss performance in a randomly...
This part of IEC 61755 defines certain dimensional limits of a 2,5 mm and a 1,25 mm diameter cylindrical zirconia (ZrO2) PC ferrule optical interface to meet specific requirements for...
This part of IEC 61755 defines certain dimensional limits of a 2,5 mm and a 1,25mm diameter cylindrical zirconia (ZrO2) 8 degrees angled-PC (APC) ferrule optical interface to meet specific...
This part of IEC 61755 defines dimensional limits and material properties of a 2,5 mm and a 1,25 mm diameter cylindrical composite ferrule optical interface to meet specific requirements for...
This part of IEC 61756 covers general information on the subject of fibre management system (FMS) interfaces. It includes references, document structure details, definitions and the rules under which a...
This part of IEC 61788 covers a test method detailing the tensile test procedures to be carried out on Cu/Nb-Ti superconductive composite wires at room temperature. This test is used...
This part of IEC 61788 covers a test method for the determination of the d.c. critical current of either Cu/Nb-Ti composite superconductors that have a copper/superconducto r ratio larger than...
This part of IEC 61788 covers a test method for the determination of the d.c. critical current of Nb3Sn composite superconductors which are fabricated by either the bronze process or...
This part of IEC 61788 covers a test method for the determination of the dc critical current of short and straight Ag- and/or Ag alloy-sheathed Bi-2212 and Bi-2223 oxide superconductors...
This part of IEC 61788 covers a test method for the determination of the residual resistance ratio (RRR) of a composite superconductor comprised of Nb-Ti filaments and Cu, Cu-Ni or...
This part of IEC 61788 specifies a test method for the resistive determination of the critical temperature of composite superconductors for industrial use. The composite superconductors covered in this standard...

<< Prev Next >>