| Product Name | Notes |
|---|---|
| A common convention for naming physical and virtual intelligent electronic devices (IEDs) is provided in this guide. The various environments where device names are needed and how a common naming... | |
| A common format for data files used for the interchange of various types of event data collected from electrical power systems or power system models is defined. Extensibility, extension mechanisms... | |
| A phasor data concentrator (PDC) is defined in this standard as a set of functions that may be performed on synchrophasor data. It describes the PMU measurement network and indicates... | |
| A practical basis is provided for the selection of voltage and current tests to be applied in evaluating the surge withstand capability of equipment connected to utility power circuits, primarily... | |
| A procedure to be used to perform a failure analysis is recommended. The procedure is primarily focused on power transformers used on electric utility systems, although it may be used... | |
| A review of generally accepted applications and coordination of protection for power system distribution lines is presented. The advantages and disadvantages of schemes presently being used in protecting distribution lines... | |
| A standard procedure for 1 naming time sequence data (TSD) files, such as files produced by digital fault recorders, power swing recorders, power quality monitors, and so on is specified. | |
| A test procedure is established to provide a uniform method for investigating the effect of operating temperature on the life expectancy of liquid-immersed transformers. The test procedures are intended to... | |
| A tutorial style document that provides additional guidelines, beyond those in IEEE C37.48(TM), for the application and coordination of high-voltage power- and distribution class current-limiting fuses. | |
| A uniform 1 method is established for determining the temperature classification for the insulation systems for open-wound, solid-cast and resin-encapsulated power and distribution transformers by testing rather than by chemical... | |
| A uniform method is established for determining the temperature classification for the insulation systems for dry-type power and distribution transformers by testing rather than by chemical composition. These insulation systems... | |
| A uniform method is established for determining the temperature classification for the insulation systems for open-wound, solid-cast and resin-encapsulated power and distribution transformers by testing rather than by chemical composition. | |
| Additional guidelines for application and coordination of high-voltage power- and distribution-class current-limiting fuses are provided. | |
| All oil-immersed or dry-type, single-phase or three-phase, outdoor or indoor shunt reactors rated over 500 kVA are covered. Terminology and general requirements are stated, and the basis for rating shunt... | |
| An error has been identified in the 2014 published version of IEEE Std C57.12.38(TM). Two dimensions were provided for the high voltage bushing height above the base of the transformer. | |
| An extended common profile for the use of Precision Time Protocol (PTP) of IEEE Std 1588-2008 in power system protection, control, automation, and data communication applications utilizing an 2 Ethernet... | |
| An extended profile for the use of Precision Time Protocol (PTP) of IEEE Std 1588-2008 in power system protection, control, automation, and data communication applications utilizing an Ethernet communications architecture... | |
| An introduction to a series of guides on the application of surge protectors and protective circuits used in information and communications technology circuits, including Smart Grid data networks, is provided... | |
| An optical interface for use between teleprotection and digital multiplexer equipment that can operate at a data rate of N times 64 kilobit per second where N = 1, 2... | |
| Applications information on fixed voltage and gated thyristor surge protective components (SPCs) is provided. Key device parameters and their sensitivities are explained. Several worked telecommunication circuit design examples are given. | |
| Assistance to equipment manufacturers and service companies to evaluate the suitability of unused natural ester insulating liquids being received from suppliers is provided in this guide. Information for transformer operators... | |
| Avalanche breakdown diodes used for surge protection on systems with voltages equal to or less than 1000 V rms or 1200 V dc are discussed in this standard. The avalanche... | |
| Bar code label requirements for specific types of distribution transformers and stepvoltageregulator s are covered in this standard. Data content for temporary and permanent barcode labeling is described as well... | |
| Certain electrical, dimensional, and mechanical characteristics and safety features of single- and three-phase, 60 Hz, liquid-immersed, self-cooled, overhead-type distribution transformers 500 kVA and smaller, high voltages 34 500 V and... | |
| Certain electrical, dimensional, and mechanical characteristics and safety features of single-and three-phase, 60 Hz, liquid-immersed, self-cooled, overhead-type distribution transformers 500 kVA and smaller, high voltages 34 500 V and below,... | |
| Certain electrical, dimensional, and mechanical characteristics are covered in this standard, and certain safety features of single-phase, 60 Hz, mineral-oil-immersed , self-cooled, pad-mounted, compartmental-type distribution transformers are taken into consideration. | |
| Certain electrical, dimensional, and mechanical characteristics are covered in this standard, and certain safety features of single-phase, 60-Hz, mineral-oil-immersed , self-cooled, pad-mounted, compartmental-type distribution transformers are taken into consideration. Thesetransformers... | |
| Certain electrical, dimensional, and mechanical characteristics are covered in this standard, It also and takes into consideration certain safety features of three-phase, 60 Hz, liquid immersed, self-cooled, submersible transformers with... | |
| Certain electrical, dimensional, and mechanical characteristics are set forth as well as certain safety features of three-phase, 60 Hz., mineral-oil-immersed , self-cooled, pad-mounted, compartmental-type distribution transformers. These transformers are rated... | |
| Certain electrical, dimensional, and mechanical characteristics are set forth as well ascertain safety features of three-phase, 60 Hz., mineral-oil-immersed , self-cooled, pad-mounted,compartm ental-type distribution transformers. These transformers are rated 5... | |
| Characteristics of ventilated dry-type transformers relating to performance, limited electrical and mechanical interchangeability, as well as recommended practice for installation of equipment are set forth in this guide. Specific rating... | |
| Common requirements for associating time tags with data items recorded or transmitted by Intelligent Electronic Devices (IEDs) are established in this standard. Time tag attributes and requirements for describing time... | |
| Concepts of power bus protection are discussed in this guide. Consideration is given to availability and location of breakers, current transformers and disconnectors as well as bus switching scenarios, and... | |
| Concepts of power bus protection are discussed in this guide. Consideration is given to availability and location of breakers, current transformers, and disconnectors as well as bus-switching scenarios, and their... | |
| Conformance tests and requirements for the coating integrity of carbon steel pole mounted enclosures containing apparatus energized in excess of 600 volts, typically located out of reach of the general... | |
| Conformance tests and requirements for the coating integrity of carbon steel pole-mounted enclosures containing apparatus energized in excess of 600 V, typically located out of reach of the general public,... | |
| Conformance tests and requirements for the coating integrity of pole mounted enclosures for application in coastal environments containing apparatus energized in excess of 600 volts, typically located out of reach... | |
| Conformance tests and requirements for the integrity of above-grade pad-mounted enclosures for application in coastal environments that contain apparatus energized in excess of 600 V and that may be exposed... | |
| Corrigenda concerning required procedures for 1 performing design tests for high voltage fuses are specified. These design tests, are appropriate to expulsion fuses, and cover interrupting tests and fuses using... | |
| Corrigenda concerning required procedures for performing design tests for high-voltage fuses are specified. These design tests, are appropriate to expulsion fuses, and cover interrupting tests and fuses using polymeric insulators. | |
| Cyber security measures require that a balance be achieved between technical feasibility and economic feasibility, and that this balance addresses the risks expected to be present at a substation. Further,... | |
| Description of design types, tables of 50 and 60 Hz ratings, supplementary ratings, construction and available accessories are provided. Methods for performing routine and design tests applicable to liquid-immersed single... | |
| Description of design types, tables of 50 Hz and 60 Hz ratings, supplementary ratings, construction, and available accessories are provided. Methods for performing routine and design tests applicable to liquid-immersed... | |
| Descriptions of products, methods, and procedures relating to stationary batteries, battery electrolyte spill mechanisms, electrolyte containment and control methodologies, and firefighting considerations are provided. | |
| Design and production tests and requirements for the integrity of submersible electrical equipment intended for installation in submerged or partially submerged environments are covered in this standard. These enclosures contain... | |
| Detailed procedures for analyzing gas from gas spaces or gas-collecting devices as well as gas dissolved in oil are described. The procedures cover: (1) the calibration and use of field... | |
| Detailed procedures for analyzing gas from gas spaces or gas-collecting devices as well as gas dissolved in oil are described. The procedures cover: 1) the calibration and use of field... | |
| Detailed procedures for interpreting Dissolved Gas Analysis results are described in this guide. The document details: 1) Overview of gas generation in transformer and DGA process; 2) The purpose and... | |
| Detailed procedures for interpreting Dissolved Gas Analysis results are described. The document details: 1) Overview of gas generation in transformer and DGA process. 2) The purpose and application of DGA. | |
| Diagnostic tests and measurements that are performed in the field on fluid-filled power transformers and regulators are described. Whenever possible, shunt reactors are treated in a similar manner to transformers. | |
| Dielectric Frequency Response (DFR) test methods of liquid immersed transformers are discussed in this guide. The guide includes recommendations for instrumentation, procedures for performing the tests, and techniques for analyzing... | |
| Directions and requirements are provided for the conversion of qualified power switchgear equipment. Examples such as low-voltage power circuit breakers; high-voltage outdoor, and medium-voltage indoor drawout power circuit breakers; medium-voltage... | |
| Electrical and mechanical requirements are set forth for liquid-immersed distribution and power transformers, and autotransformers and regulating transformers; single and polyphase, with voltages of 601 V or higher in the... | |
| Electrical and mechanical requirements for liquid-immersed distribution and power transformers, and auto transformers and regulating transformers; single- and polyphase, with voltages of 601 V or higher in the highest voltage... | |
| Electrical and mechanical requirements for liquid-immersed distribution and powertransformers, and autotransformers and regulating transformers; single- and polyphase, withvoltages of 601 V or higher in the highest voltage winding, are set... | |
| Electrical and mechanical requirements of ventilated, non-ventilated, and sealed dry-type distribution and power transformers or autotransformers (single and polyphase, with a voltage of 601 V or higher in the highest... | |
| Electrical, dimensional, and mechanical characteristics and certain safety features of single-phase, 60 Hz, liquid-immersed, self-cooled, submersible distribution transformers are covered in this standard. This standard is intended for use as... | |
| Electrical, dimensional, and mechanical characteristics are covered, taking into consideration certain safety features, for current and inductively coupled voltage transformers of types generally used in the measurement of electricity and... | |
| Electrical, dimensional, and mechanical charasteristics and certain safety features of single-phase, 60Hz, liquid-immersed, self cooled, submersible distribution transformers are covered. This standard is intended for use as a basis for... | |
| Electrical, dimensional, and related requirements for power transformer and reactor bushings that have basic impulse insulation levels (BILs) of 150 kV and above are covered. Specific values for dimensional and... | |
| Electrical, mechanical, and safety requirements of ventilated, non-ventilated, and sealed dry-type distribution and power transformers or autotransformers (single and polyphase, with a voltage of 601 V or higher in the... | |
| Errors identified in IEEE Std.C62.21-2003 are addressed in this corrigendum. | |
| General and specifi c recommendations on specifi cation, design, and application of liquid-immersed and dry-type transformers in distributed photovoltaic (DPV) power generation systems for commercial, industrial, and utility systems are... | |
| General recommendations for loading 65 C rise mineral-oil-immersed distribution and power transformers are covered. | |
| General recommendations for measuring voltage transients in dry-type distribution and power transformers are provided. Recurrent surge voltage generator circuitry, instrumentation, test sample, test point location, mounting the test coil, conducting... | |
| General test procedures for performing routine quality control test that is suitable for high volume, production line testing. Transformer connections, test methods, circuit configurations and failure detection methods are addressed. | |
| General types of LTC mechanisms, breathing configurations, and electrical designs are described for reference for determining methods of testing and evaluating dissolved gases in mineral based transformer oils in Load... | |
| Generally accepted methods of protection for ac motors are provided. This guide identifies and summarizes the functions necessary for adequate protection of motors based on type, size, and application. This... | |
| Guidance for synchronization, calibration, testing, and installation of phasor measurement units (PMUs) applied in power systems is provided. The following are addressed in this guide: (a) Considerations for the installation... | |
| Guidance is offered on the application and use of optical voltage and current sensor systems for protective relaying, covering the selection, installation, testing, and operation of sensors. Information is provided... | |
| Guidance on and recommended practices for the installation and maintenance of liquid-immersed power transformers rated 501 kVA and above with secondary voltages of 1000 V and above are provided in... | |
| Guidance on the use of outdoor power apparatus bushings is provided. The bushings are limited to those built in accordance with IEEE Std C57.19.00-1991. General information and recommendations for the... | |
| Guidelines for the following are included in the standard: insulating liquid maintenance and diagnostics, liquid reclamation, testing methods for the determination of remaining insulation (paper) life, and upgrades of auxiliary... | |
| IEEE Standard | |
| Information and general recommendations of instrumentation, circuitry, calibration, and measurement techniques of no-load losses (excluding auxiliary losses), excitation current, and load losses of power and distribution transformers are provided. The... | |
| Metal-enclosed (ME) bus assemblies f 35 or indoor and outdoor use are covered in this standard. The types of assemblies covered are nonsegregated-phase bus, cable bus, segregated-phase bus, and isolated-phase... | |
| Metal-oxide surge arresters (MOSAs) designed to repeatedly limit the voltage surges on 48 Hz to 62 Hz power circuits (>1000 V) by passing surge discharge current and automatically limiting the... | |
| Methodologies for determination of the steady-state winding hottest-spot temperature in dry-type distribution and power transformers with ventilated, sealed, solid cast, and encapsulated windings built in accordance with IEEE Std C57.12.01(TM)... | |
| Methodologies for determination of the steady-state winding hottest-spot temperature in dry-type distribution and power transformers with ventilated,scaled, solid cast,and encapsulated windings built in accordance with IEEE std C57.12.01 and IEC... | |
| Methods for determining the value of the power factor for inductive low-voltage (1000 V ac and lower) test circuits are provided. These methods are used in determining the power factor... | |
| Methods for performing tests specified in IEEE Std C57.12.00 and other standards applicable to liquid-immersed distribution, power, and regulating transformers are described. Instrument transformers, step-voltage and induction voltage regulators, arc... | |
| Methods for performing tests specified in IEEE Std C57.12.00TM and other standards applicable to liquid-immersed distribution, power, and regulating transformers are described. Instrument transformers, step-voltage and induction voltage regulators, arc... | |
| Methods for performing tests specified in IEEE Std C57.12.00TM-2006 and other standards applicable to liquid-immersed distribution, power, and regulating transformers are described. Instrument transformers, step-voltage and induction voltage regulators, arc... | |
| Milliampere-range current transformers (CTs) are not addressed in the scope of IEEE Std C57.13-2016. The evaluation, certification, and specification of milliampere CTs is enabled in this standard similar to the... | |
| Natural and synthetic ester-immersed transformers are handled in this guide. Thefollowing is addressed in this guide: a) The theory of combustible gas generation in a natural and synthetic ester-filled transformer; | |
| Protection methods for different types of phase shifting transformers (PST) are provided in this guide, and the interaction between protection and operating conditions of PSTs is discussed. Models representing PSTs... | |
| Provided in this recommended practice are calculation methods for conservatively evaluating the feasibility for an existing installed dry-type or liquid immersed transformer, to supply nonsinusoidal load currents as a portion... | |
| Ratings, construction, and testing of dead-front control switchboards containing, but not limited to, devices such as switches, control devices, instrumentation, metering, monitoring, alarms, annunciators, protective and auxiliary relays, and regulating... | |
| Reaffirmed December 2010. This guide provides assistance in selecting the most appropriate type of surge protector for a particular data, communication, and/or signaling circuit application. The purpose of this guide... | |
| Recommendations are given for reactors intended for series connection, in both transmission and distribution systems, to control power flow under steady-state conditions and/or limit fault current under short-circuit conditions. Dry-Type... | |
| Recommendations are made, where possible, regarding the performance and evaluation of temperature rise tests on liquid-immersed power transformers beyond nameplate ratings in this recommended practice. The intent is to assist... | |
| Recommendations believed essential for the application of overcurrent protective devices applied to limit the exposure time of transformers to short circuit current are set forth. Transformer coordination curves are presented... | |
| Recommendations for operation and maintenance of dry-type distribution and power transformers is provided. | |
| Recommendations regarding mineral oil tests and evaluation procedures are made in this guide; references are made to methods of reconditioning and reclaiming conventional petroleum (mineral) dielectric insulating liquids, the levels... | |
| Required definitions (for cutout type sectionalizers), ratings, procedures for performing design tests and production tests, constructional requirements, and application considerations for overhead and pad-mounted, dry-vault, and submersible automatic line sectionalizers... | |
| Required definitions, ratings, procedures for performing design tests and productiontests, constructional requirements, and application considerations for overhead and padmounted,dry-vault , and submersible automatic line sectionalizers for ac systems are specified. | |
| Required definitions, ratings, procedures for performing design tests, production tests and construction requirements for Overhead, Pad Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for Alternating Current... | |
| Required definitions, ratings, procedures for performing design tests, production tests and construction requirements for Overhead, Pad Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers, cutout mounted reclosers and Fault Interrupters... | |
| Required procedures for performing design tests for high-voltage distribution class and power class fuses, as well as for fuse-disconnecting switches and enclosed single-pole air switches, are specified. These design tests,... | |
| Required procedures for performing design tests for high-voltage fuses, as well as for fuse disconnecting switches, are specified. These design tests, as appropriate to a particular device, include the following... | |
| Required ratings, construction requirements, design test requirements, applications and suggested practices for all high voltage enclosed indoor and outdoor and non-enclosed indoor and outdoor switches rated above 1,000 V are... | |
| Requirements for interrupter switches, interrupters or interrupting aids used on or attached to switches rated for high-voltage ac above 1000 V and used indoors, outdoors, or in enclosures for non-fault... | |
| Series-Connected dry-type air-core single-phase and three-phase outdoor or indoor reactors of distribution and transmission voltage class that are connected in the power system to control power flow under steady-state conditions... | |
| Single-phase instrument transformers of a nominal system voltage of 115 kV and above with capacitive insulation system for line-to-ground connection and for both indoor and outdoor application is discussed in... | |
| Small power transformers have become a significant element in distribution systems supplying large commercial customers like major resort hotels and site-specific industrial customers that desire the local utility to own,... | |
| Specifications for high voltage (abo 32 ve 1000 volts) Class A and Class B expulsion and current-limiting fuses. | |
| Specifications for high voltage (above 1000 volts) Class A and Class B expulsion and current-limiting fuses. This includes: a) Expulsion type Class A [distribution class] fuses, fuse cutouts, fuse disconnecting... | |
| Specifications for high voltage (above 1000 volts) expulsion and current-limiting type power class fuses, fuse disconnecting switches, their associated fuse links, disconnecting cutouts, and accessories for these devices are covered. | |
| Specifications for high voltage (above 1000 volts) expulsion type distribution class fuses, fuse cutouts, fuse disconnecting switches, their associated fuse links, disconnecting cutouts, and accessories for these devices are covered. | |
| Specifications for high-voltage (above 1000 V) distribution class enclosed single-pole air switches and associated accessories with rated voltages from 1 kV through 8.3 kV are established. All of these devices... | |
| Specifications for high-voltage (above 1000 V) distribution Current-limiting fuses and disconnecting switches and associated accessories with rated voltages from 1 kV through 38 kV are established. All of these devices... | |
|
IEEE Draft Standard Requirements for Liquid-Immersed Power Transformers -- PC57.12.10/D2.2, Feb 2017
IEEE Draft Standard Requirements for Liquid-Immersed Power Transformers -- PC57.12.10/D2.5, Jul 2017
|
Standard Docs |
| Standard terminal markings and connections are described for single-phase and three-phase distribution, power, and regulating ransformers. For terminal markings, it covers sequence designation, external terminal designation, neutral terminal designation, grounded... | |
| Standard terminal markings and connections are described for single-phase andthree-phase distribution, power, and regulating transformers. For terminal markings, it coverssequence designation, external terminal designation, neutral terminal designation, grounded terminal designation,... | |
| Surge protective components (SPCs) used in power and telecom surge protective devices (SPDs) and equipment ports are covered in the IEEE C62.42 guide series. The following are covered in this... | |
| Surge protectors for application on multiconductor balanced or unbalanced data, communications, and signaling circuits with voltages equal to or less than 1000 Vrms, or 1200 V dc are covered by... | |
| Technical corrections to 5.1.9 of IEEE Std C57.12.10 are discussed in this corrigendum. | |
| Test code for switching (except capacitive current) and fault making tests for switching devices for alternating current, rated above 1000 V and used indoors, outdoors, or in enclosures is specified... | |
| Test methods and performance criteria for plug-in (portable) multiservice (multiport) surge protective devices (MSPDs) intended to protect equipment connected to one or more metallic conductive telecommunication line(s) and a 120... | |
| The application of tertiary and stabilizing windings in liquid-immersed power transformers, as covered by IEEE Std C57.12.00™, as well as recommendations to evaluate the need or convenience of having such... | |
| The C62.42 guide series covers surge protective components (SPCs) used in power and telecom surge protective devices (SPDs) and equipment ports. This Overview part covers:- Protective functions both non-linear and... | |
| The definition and application of function numbers and acronyms for devices and functions used in electrical substations and generating plants and in installations of power utilization and conversion apparatus are... | |
| The definition of constant k in Equation 2 (in 8.3) and line terminal rated voltage in the last paragraph of 10.8.2 are corrected in this corrigendum. | |
| The detection and location of acoustic emissions (AEs) from partial discharges (PDs) and other sources in liquid-insulated power transformers and reactors are covered in this guide. A means of associating... | |
| The document provides guidance for synchronization, calibration, testing, and installation of Phasor Measurement Units (PMU) applied in power system protection and control. The following are addressed in this guide: (a)... | |
| The document provides guidance for synchronization, calibration, testing, and installation of Phasor Measurement Units (PMU) applied in power system. The following are addressed in this guide: (a) Considerations for the... | |
| The economic loss evaluation of liquid-filled distribution and power transformers, dry-type distribution and power transformers, and reactors is covered in this guide. | |
| The electrical, dimensional, and related special requirements for high current rating power transformer bushings within bus enclosures that have rated continuous current in excess of 5000 A are addressed in... | |
| The evaluation and handling procedures for natural ester transformer insulating fluids are covered. The guide¿s purpose is to assist the transformer operator in evaluating the serviceability of new, unused fluids... | |
| The functional, performance, and testing guidelines for a phasor data concentrator are described in this guide. Supporting information is also provided. | |
| The methods and requirements for qualifying switchgear assemblies for indoor areas outside of the containment in nuclear power generating stations are described in this document. These assemblies include: metal-enclosed low-voltage... | |
| The performance of transformers in the presence of oscillatory transients is addressed in this guide. Oscillatory transients are typically produced by the interaction of the switching device, transformer, load, and... | |
| The performance, electrical and mechanical interchangeability, and the safety of the equipment are covered. The proper selection of such equipment is established as a basis for use in this standard. | |
| The purpose of this document is to guide the power system user in applying, installing and operating digital communication channels for the purpose of protective relaying. | |
| The requirements in this standard are applied to 50 Hz and 60 Hz, two-pole and four pole, cylindrical-rotor synchronous generators driven by steam turbines and/or by combustion gas turbines. The... | |
| The scope of the document is a procedure that is recommended for naming time sequence data (TSD) files, such as, transient records, event sequences and periodic logs. The file names... | |
| The scope of the guide will be the application of relays and other devices for protecting transformers used in electric power utility transmission networks and distribution systems. | |
| The scope of this Recommended Practice will be to identify the means for timely and efficient exchange of information between manufacturers and users of protection related equipment with respect to... | |
| The Standard covers the requirements for the design and construction of control cabinets on power transformers. It does not apply to distribution nor padmount transformers. | |
| Theory, application of phase-shifting transformers, and the difference of specification and testing to standard system transformers are described. Various types of phase-shifting transformers and how to select the optimal design... | |
| This 1 standard is a compilation of terminology and definitions related to electric power and distribution transformers and associated apparatus. It also includes similar terminology relating to power systems and... | |
| This amendment is applicable to mechanical operations tests for all equipment covered by the complete standard. It further defines criteria for acceptance at the completion of the tests. | |
| This corrigendum clarifies temperature control for aging experiments in 4.5.1 that was a result of the combination of the two previous test standards. This corrigendum selects the method from the... | |
| This corrigendum corrects an error where the user of this document was directed to gather the wrong column information from the NOAA website for use in calculations. The document erroneously... | |
| This document describes the methods and requirements for qualifying switchgear assemblies for indoor areas outside of the containment in nuclear power generating stations. These assemblies include: Metal-enclosed low-voltage power circuit... | |
| This document offers guidance on the application and use of optical voltage and current sensor systems for protective relaying, covering selection, installation, testing, and operation of the sensors. This Guide... | |
| This Guide addresses the application of transformers in the presence of oscillatory switching transients. These oscillatory transients are typically produced by the interaction of the switching device, transformer, load, and... | |
| This guide addresses the performance of transformers in the presence of oscillatory transients. Oscillatory transients are typically produced by the interaction of the switching device, transformer, load, and system. This... | |
| This guide addresses the performance of transformers in the presence of oscillatory transients. Oscillatory transients are typically produced by the interaction of the switching device, transformer, load,and system. This Guide... | |
| This guide advises on the economic loss evaluation of liquid filled distribution and power transformers, dry type distribution and power transformers, and reactors. | |
| This guide application is for Natural and Synthetic Ester-immersed transformers. This guide addresses the following: *The theory of combustible gas generation in a natural and synthetic ester filled transformer *Interpretation... | |
| This guide applies to mineral oil used in transformers, load tap changers, voltage regulators, reactors, and circuit breakers. The guide discusses the following: a) Analytical tests and their significance for... | |
| This guide applies to protective relay applications involving electric service to consumers that requires a transformation between the utilitys supply voltage and the consumers utilization voltage. It describes the factors... | |
| This guide applies to the protection of shunt power capacitor banks and filter capacitor banks. Included are guidelines for reliable applications of protection methods intended for use in many shunt... | |
| This guide consolidates most electric utility power industry 1 practices, accepted theories, existing standards/guides, definitions, and technical references as they specifically pertain to surge protection of electric power generating plants. | |
| This guide consolidates most electric utility power industry practices, accepted theories, existing standards/guides, definitions, and technical references as they specifically pertain to surge protection of electric power generating plants. Where... | |
| This guide contains general and specific recommendations fo 1 r grounding current and voltage transformer secondary circuits and cases of connected equipment. Although most diagrams included in this guide show... | |
| This guide covers general recommendations for the loading of dry-type distribution and power transformers installed in ventilated, non-ventilated, and sealed type enclosures. | |
| This guide covers identification of the key parameters that can be monitored for obtaining an indication of the condition of liquid-immersed transformers. It also covers risk/benefit analysis, sensor application, and... | |
| This guide covers mineral insulating oil commonly defined as transformer oil; definition and description of reclaiming procedures; the test methods used to evaluate the progress and end point of the... | |
| This guide covers suggested test requirements for Power System Protection Scheme Testing, System Application Tests, the scope and level of tests based on the application, and benefits of the overall... | |
| This guide covers the application of air gap, gas tube, metal oxide varistor, and avalanche junction semiconductor components used in surge protective devices, equipment, or systems involving low-voltage power, data,... | |
| This guide covers the application of metal-oxide surge arresters to safeguard electric power equipment, with a nominal operating voltage 1000 V and above, against the hazards of abnormally high-voltage surges... | |
| This guide describes field test methods that assure that current transformers are connected properly, are of marked ratio and polarity, and are in a condition to perform as designed both... | |
| This guide describes measures that may be taken to help mitigate tank rupture of energized liquid-immersed power transformers and reactors due to internal electrical faults. This guide does not cover... | |
| This guide describes the effects of Geomagnetic Disturbances (GMD) on power transformers when there is the presence of Geomagnetically Induced Current (GIC) in a power transformer. It establishes specification parameters... | |
| This guide describes the functional, performance and testing guidelines for a Phasor Data Concentrator. Supporting information is also provided. | |
| This guide describes the testing of fault current limiters (FCLs) operating on condition based impedance increase for AC systems 1000 V and above. This guide does not include constant impedance... | |
| This guide discusses and recommends methods of testing and evaluating dissolved gases in mineral based transformer oils found in Load Tap Changers (LTCs). General types of LTC mechanisms, breathing configurations... | |
| This guide discusses and recommends methods of testing and evaluating dissolved gasses in mineral based transformer oils found in Load Tap Changers (LTCs). General types of LTC mechanisms, breathing configurations... | |
| This guide documents accepted protection practices for transmission-to-gene ration interconnections. It is intended to cover the protection system applications at the interconnections between transmission systems and generation facilities greater than... | |
| This guide encompasses the application of surge protective devices (secondary arresters) from the secondary terminals of the distribution transformer to the line side of the service entrance panel. | |
| This guide encompasses the application of surge protective devices (secondary arresters) fromthe secondary terminals of the distribution transformer to the line side of the service equipment. | |
| This guide is applicable to the detection and location of acoustic emissions from partial discharges and other sources in oil immersed power transformers and reactors. Both electrical (partial discharge) and... | |
| This guide is applicable to the measurement of Frequency Response Analysis (FRA) of oil immersed power transformers. It is intended to provide the user with the requirements and specifications for... | |
| This guide is intended for the application of dissolved gas analysis (DGA) techniques on oil-immersed transformers and reactors applied during factory temperature rise tests. It contains recommended procedures for sampling,... | |
| This guide is intended for use in establishing a methodology to evaluate expected longterm performance of infrequently operated switch contacts used within insulating liquid transformers. These switch contacts are typically... | |
| This guide presents practical line current differential schemes using digital communication. Operating principles, synchronization methods, channel requirements, current transformer requirements, external time reference requirements, backup considerations, testing considerations and troubleshooting... | |
| This guide presents test approaches and procedures for the components and the overall protection and control system functions. Test of equipment in the system protection scheme, associated communications equipment, auxiliary... | |
| This guide provides application recommendations to assist in selection of separately mounted current-limiting fuses to be installed upstream and in series with low-voltage ac power circuit breakers. | |
| This guide provides evaluation methods and application considerations for high voltage (>1000 V) switches, as covered in IEEE Std C37.30.1, under wind loading conditions. This includes testing methods to meet... | |
| This Guide provides general and specific recommendations on specification, design and application of liquid-immersed and dry-type transformers in Distributed Photovoltaic (DPV) Power Generation Systems for commercial, industrial and utility systems. | |
| This guide provides guidance and recommended practices on the installation and maintenance of liquid-immersed power transformers rated 501 kVA and above with secondary voltages of 1000 V and above. This... | |
| This guide provides information on the selection and application considerations for the unit power transformer and unit auxiliaries power transformer. Consideration is given to connections that include direct connection and... | |
| This guide provides information to assist in evaluating the effect of solar radiation on outdoor metal-enclosed switchgear including metal-enclosed bus and control switchboards. Specific data are given in the form... | |
| This guide provides information to assist in selection of current-limiting fuses for use in low with voltage ac power circuit breakers with separately mounted current-limiting fuses. | |
| This guide provides methods for determining the value of power factor for inductive low-voltage (1000 volts ac and below) test circuits. These methods are used in determining power factor during... | |
| This guide provides requirements and guidance for the seismic qualification of metal-enclosed power switchgear assemblies including switching, interrupting, control, instrumentation, metering, and protective and regulating devices mounted therein. As used... | |
| This guide sets forth recommendations believed essential for the application of overcurrent protective devices that limit the exposure time of dry-type transformers to short-circuit currents. This guide is not intended... | |
| This is a guide for the transportation of transformers and reactors rated 10,000 kVA or larger. The guide provides information for minimizing the risk of damage and delays in the... | |
| This is a guide for the transportation of transformers and reactors rated 10,000 kVA orlarger. The guide provides information for minimizing the risk of damage and delays in themoving of... | |
| This paralleling guide describes and compares control methods of paralleling power transformers equipped with load tap changers (LTC) or series regulators. The control methods include: master/follower, circulating current, power factor,... | |
| This paralleling guide describes and compares control methods of paralleling regulating transformers. The control methods include: master/follower, circulating current, power factor, circulating reactive current and negative reactant methods. This guide... | |
| This project is to develop a standard for 50 and 60 Hz liquid immersed distribution substation transformers with ratings of 10 000 kVA and below three phase, 6667 kVA and... | |
| This recommended practice is focused on the wide-band measurement of the apparent charge of partial discharges (PD) which may occur in liquid-filled power transformers and shunt reactors excited by AC... | |
| This revision addresses substantive changes to Clause 5, 10 and 11 of existing C57.12.91-2001 to reflect current practice in the testing procedures of dry-type transformers. This revision does not address... | |
| This standard adopts the IEC 60270-2000-12 and defines methods of measuring partial discharges that may occur in energized power switchgear apparatus, in flaws, voids and interfaces of non-self restoring insulation... | |
| This standard adopts the IEC 60270-2000-12 and defines methods of measuring partial discharges that may occur in energized power switchgear apparatus, in flaws, voids and interfaces of non-self rstoring insulation... | |
| This standard applies to all liquid-immersed distribution, power and regulating transformers that are designed to operate at temperatures that exceed the normal thermal limits of C57.12.00, under continuous load, in... | |
| This Standard applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages above 1000 V... | |
| This standard applies to devices used f 1 or the purpose of controlling the ground current or the potentials to ground of an alternating current system. These devices are: groundingtransformer... | |
| This standard applies to devices used for the purpose of controlling the ground current or the potentials to ground of an alternating current system. These devices are: groundingtransformer s, ground-fault... | |
| This standard applies to metal-oxide surge arresters (MOSAs) designed to repeatedly limit the voltage surges on 48 Hz to 62 Hz power circuits (> 1000 V) by passing surge discharge... | |
| This standard applies to metal-oxide surge arresters designed to repeatedly limit the voltage surges on 48 Hz to 62 Hz power circuits (>1000 V) by passing surge discharge current and... | |
| This standard applies to single-phase instrument transformers of a nominal system voltage of 115 kV and above with capacitive insulation system for line-to-ground connection and for both indoor and outdoor... | |
| This standard applies to surge protective devices designed for application on the low-voltage supply mains (1000 V rms and less, frequency between 48 and 62 Hz) and intended to be... | |
| This standard applies to surge protective devices designed for application on the low-voltage supply mains (1000 V rms and less, frequency between 48 Hz and 62 Hz) and intended to... | |
| This standard applies to surge protectors for application on multiconductor balanced or unbalanced data, communications, and signaling circuits with voltages equal to or less than 1000 V rms, or 1200... | |
| This standard covers certain electrical, dimensional, and mechanical characteristics and safety features of single- and three-phase, 60 Hz, mineral-oil-immersed , self-cooled, overhead-type distribution transformers 500 kVA and smaller, high voltages... | |
| This standard covers certain electrical, dimensional, and mechanical characteristics and takes into consideration certain safety features of single-phase, 60 Hz., mineral-oil-immersed , self cooled, pad-mounted, compartmental-type distribution transformers. These transformers... | |
| This standard covers certain electrical, dimensional, and mechanical characteristics and takes into consideration certain safety features of single-phase, 60 Hz., mineral-oil-immersed , selfcooled, pad-mounted, compartmental-type distribution transformers. These transformers are... | |
| This standard covers certain mechanical requirements for liquid-immersed distribution transformers in respect to tank strength as well as static and dynamic tank pressure mitigation. This standard can be applied to... | |
| This standard covers electrical and mechanical performance and test requirements for tap changers installed in voltage regulating power and distribution transformers of all voltage and kVA ratings. It covers load... | |
| This standard covers electrical characteristics and mechanical features of liquid-immersed transformers 69 kV or less (but not limited to 69 kV), used for supplying electric power to direct arc-melting furnaces. | |
| This Standard covers required definitions, ratings, procedures for performing design tests, and production tests, and construction requirements for subsurface, vault, and pad-mounted load-interrupter switchgear and fused load-interrupter switchgear for ac... | |
| This standard defines test methods and performance criteria for plug-in (portable) Multiservice (Multiport) Surge Protective Devices, MSPDs, intended to protect equipment connected to one or more metallic conductive telecommunication line(s)... | |
| This standard describes the methods and conditions for seismic qualification of protective relays and auxiliaries such as test and control switches, terminal blocks, and indicating lamps for use in nuclear... | |
| This standard establishes specifications for high voltage (above 1000 volts) 1 distribution and power class expulsion, current-limiting and combination type external capacitor fuses and accessories, with rated voltages from 1... | |
| This standard establishes specifications for high voltage (above 1000 volts) distribution and power class expulsion, current-limiting and combination type external capacitor fuses and accessories, with rated voltages from 1 kV... | |
| This standard establishes specifications for high voltage (above 1000 volts) distribution class enclosed single-pole air switches and associated accessories with rated voltages from 1 through 8.3 Kv. All of these... | |
| This standard gives the basic requirements to be met by series connected, solid-state, self-restoring overcurrent protectors (OCPs) for the protection of telecommunication equipment and lines. This standard should be used... | |
| This standard is a compilation of terminology and definitions related to electric power and distribution transformers and associated apparatus. It also includes similar terminology relating to power systems and insulation... | |
| This standard is divided into six clauses. Clause 1 provides the scope and purpose of this standard. Clause 2 lists references to other standards that are useful in applying this... | |
| This standard is intended for use as a basis for establishing the performance, electrical and mechanical interchangeability, and safety of the equipment covered, and to assist in the proper selection... | |
| This standard is intended for use as a basis for establishing the performance, interchangeability, and safety of the equipment covered and to assist in the proper selection of such equipment. | |
| This standard is intended to set forth characteristics relating t 1 o performance, limited electrical and mechanical interchangeability, and to assist in the proper selection of said equipment. Specific rating... | |
| This standard is intended to set forth characteristics relating to performance, limited electrical and mechanical interchangeability, and safety of the equipment described, and to assist in the proper selection of... | |
| This standard is to be read in conjunction with IEC 62271-1:20xx17, to which it refers and which is applicable unless otherwise specified in this standard. In order to simplify the... | |
| This standard practice provides rating data, construction requirements, testing andcalculation methods for dry-type or liquid-filled semiconductor power rectifier transformers. These transformers supply non-sinusoidal load currents and are subject to higher... | |
| This standard provides a basis for the electronic reporting of transformer test data on liquid immersed distribution transformers as defined in the IEEE C57.12.2X, C57.12.3X and C57.12.4X standards series. The... | |
| This standard specifies a common profile for use of IEEE 1588-1 2008 Precision Time Protocol (PTP) in power system protection, control, automation and data communication applications utilizing an Ethernet communications... | |
| This standard specifies design test requirements for high-voltage (above 1000 V) fuses, distribution enclosed single-pole air switches, disconnecting cutouts, fuse disconnecting switches, and accessories for use on ac distribution systems. | |
| This trial-use guide consists of general recommendations for evaluation procedures and acceptance criteria for gases generated in oil- filled transformers and reactos during factory temperature rise tests. | |
| This voluntary consensus standard sets forth the requirements for outdoor power transformer application. This standard is intended for use as a basis for performance, interchangeability, and safety of equipment covered,... | |
| This voluntary consensus standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance, interchangeability, and safety of the equipment... | |
| To implement new information to reflect evolving technology and industry practices, and to clarify, reorganize, and improve the presentation of the application Guide. The scope of the revised standard will... | |
| Transformer connections, test methods, circuit configurations and failure analysis of lightning impulse and switching impulse testing of power transformers are addressed. This guide is also generally applicable to distribution and... | |
| Two types of design tests for relays and relay systems that relate to the immunity of this equipment to repetitive electrical transients are specified. Test generator characteristics, test waveforms, selection... |