IEEE - Institute of Electrical and Electronics Engineers, Inc. Datasheets for Standards and Technical Documents
Standards and technical documents includes standards, codes, regulation, handbooks, manuals, comprehensive guides and other formal publications. Standards, codes, and regulation establish uniform specifications, procedures or technical criteria.
Standards and Technical Documents: Learn more
| Product Name | Notes |
|---|---|
| "A proper design of the substation bus insures a safe and reliable operation of the substation and the power system. Two different types of buses are used in substations, the... | |
| "This International Standard addresses the creation, analysis and sustainment of architectures of systems through the use of architecture descriptions. A conceptual model of architecture description is established. The required contents... | |
| "This standard specifies interchange and arithmetic formats and methods for binary and decimal floating-point arithmetic in computer programming environments. This standard specifies exception conditions and their default handling. An implementation... | |
| A mechanism for prioritization of management frames is provided and a protocol to communicate management frame prioritization policy is specified in this amendment. | |
| A method of calculating the current-temperature relationship of bare overhead lines, given the weather conditions, is presented. Along with a mathematical method, sources of the values to be used in... | |
| A method of calculating the current-temperature relationship of bare overhead lines, giventhe weather conditions, is presented. Along with a mathematical method, sources of the values to be used in the... | |
| A proper design of the substation bus insures a safe and reliable operation of the substation and the power system. Two different types of buses are used in substations, the... | |
| Additional computer specific requirements to supplement the criteria and requirements of IEEE Std 603-2009 are specified. Within the context of this standard, the term computer is a system that includes... | |
| Additional specific requirements to supplement the criteria and requirements of IEEE Std 603 are specified for programmable digital devices. Within the context of this standard, the term programmable digital device... | |
| all indoor and outdoor cable terminations used on alternating-current cables having laminated insulation rated 2.5 kV through 765 kV or extruded insulation rated 2.5 kV through 500 kV are covered,... | |
| Amendment to IEEE Std 802.11(TM)-2012.This amendment specifies enhancements to the IEEE 802.11 medium access control (MAC) for robust audio video (AV) streaming, while maintaining coexistence with other types of traffic. | |
| An electric penetration assembly is an assembly of insulated electric conductors, conductor seals, module seals (if any), and aperture seals that provides the passage of the electric conductors through a... | |
| Applications information on fixed voltage and gated thyristor surge protective components (SPCs) is provided. Key device parameters and their sensitivities are explained. Several worked telecommunication circuit design examples are given... | |
| As the demand and supply for 3D technologies growing, the development of accurate quality assessment techniques shall be used to develop the industries of the 3D display devices and signal... | |
| Basic requirements, direction, and methods for qualifying Class lE connection assemblies for service in nuclear power generating stations and other nuclear facilities are provided in this standard. These requirements include... | |
| Common requirements for testing of AC capacitive current switching devices with nominal system voltage above 1000 V are provided in this standard | |
| Correcting the axis labels of a figure J1 located in annex J. | |
| Corrections are made by this corrigendum to material already published in IEEE Std 529-1980. | |
| Corrections made to Clause 11, Clause 17, Annex C, and Annex H in IEEE Std 80-2013. (Incorporated into IEEE Std 80-2013.) | |
| Corrections made to Clause 11, Clause 17, Annex C, and Annex H in IEEE Std 80-2013. | |
| Corrections to Equation 16, and Equation 18 through Equation 20 are addressed in this corrigendum. | |
| Criteria are established in this standard for variable selection, performance, design, and qualification of accident monitoring instrumentation for anticipated operational, design basisevents and Severe Accidents. | |
| Criteria are established in this standard for variable selection, performance, design, and qualification of accident monitoring instrumentation, and include requirements for display alternatives for accident monitoring instrumentation, documentation of design... | |
| Criteria are provided for the design of an integrated security system for nuclear power generating stations. Requirements are included for the overall system, interfaces, subsystems, and individual electrical and electronic... | |
| Criteria are provided for the design of an integrated security system for nuclear powergenerating stations. Requirements are included for the overall system, interfaces, subsystems, andindividual electrical and electronic equipment. This... | |
| Criteria for the minimum requirements 1 in the selection design, installation, and qualification of raceway systems for Class 1 E circuits for nuclear power generating stations is provided. It also... | |
| Criteria for the minimum requirements in the selection design, installation, and qualification of raceway systems for Class 1E circuits for nuclear power generating stations are provided in this standard. Methods... | |
| Criteria for variable selection, performance, design, and qualification of accident monitoring instrumentation are established in this standard. Included requirements for display alternatives for accident monitoring instrumentation, documentation of design bases,... | |
| Criteria that establish protection requirements for Class 1E power systems and equipment are prescribed in this standard. The purpose of and the means for obtaining protection from electrical and mechanical... | |
| Definitions are provided for the purpose of promoting clarity and consistency in the use of radar terminology. The definitions represent the consensus of a panel of radar experts. | |
| Definitions, service conditions, ratings, interchangeable construction features, and tests are established for loadbreak and deadbreak separable insulated connector systems for use on power distribution systems rated 2.5 kV through 35... | |
| Design tests for shield resistance, simulated touch current, and a simulated fault-current initiation for insulation shields used on cable accessories, specifi cally 15 kV through 35 kV class joints, and... | |
| Direction for the implementation of the requirements of IEC/IEEE 60780-323 as they apply to the specific features of safety-related actuator qualification are provided. This standard establishes criteria for qualification of... | |
| Electrical ratings and test requirements of cable joints used with extruded andlaminated dielectric shielded cable rated in preferred voltage steps from 2.5 kV to 500 kV areestablished in this standard. | |
| Enhancements to the IEEE 802.11 physical layers (PHYs) and medium access control (MAC) sublayer to support operation in the white spaces in television bands are defined. | |
| Excitation system and power system stabilizer models suitable for use in large-scale system stability studies are presented. Important excitation limiters and supplementary controls are also included. The model structures presented... | |
| General considerations are presented for the electrical protection of telecommunication facilities serving electric supply locations. This document contains material which is common to the 487-family of Standards (i.e., dot-series) including... | |
| General recommendations for performing maintenance work on energized power lines are pro-vided. Technical explanations as required to cover certain laboratory testing of tools and equipment, field maintenance and care of... | |
| General recommendations for performing maintenance work on energized power lines are provided. Technical explanations as required to cover certain laboratory testing of tools and equipment, field maintenance and care of... | |
| General recommendations for the selection of methods, equipment, and tools that have been found to be practical for the stringing of overhead transmission line conductors and overhead groundwires are provided. | |
| General requirements and methods for qualifying electric cables and splices for nuclear facilities are provided. Cable, wire, and splices within or integral to other devices (e.g., instruments, panels, motors) should... | |
| Goals for the design of electrical systems that include both linear and nonlinear loads are established in this recommended practice. The voltage and current waveforms that may exist throughout the... | |
| Guidance for the calculation of power station ground potential rise (GPR) and longitudinal induction (LI) voltages is provided, as well as guidance for their appropriate reduction from worst-case values, for... | |
| Guidance on basic qualification principles 1 and appropriate methods of demonstrating the qualification of equipment used in nuclear facilities is provided in this standard. The principles, methods, and procedures described... | |
| Guidance on basic qualification principles and appropriate methods of demonstrating the qualification of equipment used in nuclear facilities is provided in this standard. The principles, methods, and procedures described are... | |
| High-potential test voltages for excitation systems used with synchronous machines are established. Test voltages are established based on whether equipment is connected to the exciter power circuit or is electrically... | |
| IEC/IEEE 60079-30-1 is intended to provide a comprehensive overview of the essentialrequirement s and testing appropriate to electric surface heating equipment used in explosiveatmospheres . The requirements of this part... | |
| IEEE 45 has grown due to new technology and methods. As a result, the document has been divided into a base document (IEEE 45) and eight sub-documents IEEE 45.1 through... | |
| IEEE Project 7010 Well-being Metrics for Autonomous and intelligent Systems is a standard for measuring the impact of artificial intelligence or autonomous and intelligent systems (A/IS) on humans. The overall... | |
| IEEE Standard 519, IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems [B1], provides procedures for controlling harmonics on the power system along with recommended limits for... | |
| IEEE Standard 592-1990, IEEE Standard for Exposed Semiconducting Shields on High-Voltage Cable Joints and Separable Insulated Connectors, provides design tests for shield resistance and a simulated fault-current initiation for exposed... | |
| IEEE STD 422 provides guidance for the design and installation of cable raceway systems for all types of electric generating facilities except for nuclear power plants and nuclear facilities, and... | |
| IEEE-45-8 is a member of the IEEE 45 Series and associated with eight sub-documents (IEEE-45.1 through 45.8). Although intended to provide a consensus of recommended practices for cable systems on... | |
| Implementation independent specification for a software interface to information systems containing data pertinent to the diagnosis and maintenance of complex systems consisting of hardware, software, or any combination thereof. These... | |
| In this guide is the application of Damped AC (DAC) for field testing 1 of power cables isdescribed. DAC voltage withstand testing and diagnostic tests and measurements that areperformed in... | |
| Information to assist in determining the electrical parameters of communication and control cables necessary to improve the overall reliability of these cables when used in high-voltage environments is the objective... | |
| It provides recommendations for the design, installation, maintenance and repair of trace heating equipment and associated control and monitoring equipment. It does not cover devices that operate by induction heating,... | |
| Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead-acid storage batteries used for standby service are provided. This... | |
| Means for improved safeguarding of personnel while operating or maintaining equipment located in electrolytic cell line working zones are provided in this standard. Related requirements for equipment and electrical conductor... | |
| Means for improved safeguarding of personnel while operating or maintaining equipment located in electrolytic cell line working zones are provided. Included are related requirements for equipment and electrical conductor installations. | |
| Methods for defining the dc load and for sizing a lead-acid battery to supply that load for stationary battery applications in full float operations are described. Some factors relating to... | |
| Methods for defining the dc load and for sizing a lead-acid battery to supply that load for stationary battery applications in full-float operations are described in this recommended practice. Some... | |
| Methods for defining the dc load and for sizing a lead-acid battery to supply that load for stationary battery applications in full-float operations are described. Some factors relating to cell... | |
| Methods for qualifying static battery chargers, inverters and uninterruptible power supply (UPS) systems for Class 1E installations outside containment in nuclear power generating stations are described in this standard. Similar... | |
| Minimum functional and design criteria for the power, instrumentation, and control portions of nuclear power generating station safety systems are established. The criteria are to be applied to those systems... | |
| Modifications to both the IEEE 802.11(TM) physical layer (PHY) and the medium access control (MAC) sublayer to enable operation of license-exempt IEEE 802.11 wireless networks in frequency bands below 1... | |
| Modifications to IEEE Std 802.11™-2016, above the physical layer (PHY), to enable delivery of preassociation service discovery information to IEEE 802.11 stations (STAs) are defined in this amendment., above the... | |
| P344 will remain as Recommended Practice | |
| Practices are provided for establishing procedures that will yield data to demonstrate that the equipment can meet its performance requirements during and/or following one safe shutdown earthquake event preceded by... | |
| Procedures for demonstrating the adequacy of new Class 1E transformers, located in amild environment of a nuclear power generating station, to perform their required safety functionsunder postulated service conditions are... | |
| Protocols, procedures, and managed objects to enhance the ability of IEEE 802.11™ media to provide transit links internal to IEEE 802.1Q™ bridged networks are specified in this amendment to IEEE... | |
| Protocols, procedures, and managed objects to enhance the ability of IEEE 802.11(TM) media to provide transit links internal to IEEE 802.1Q(TM) bridged networks are specified in this amendment to IEEE... | |
| Provides a consensus of recommended practices for system testing in marine electrical engineering as applied specifically to vessels, shipboard systems, and equipment | |
| Qualification methods for Class 1E vented lead acid batteries and racks to be used in nuclear power generating stations outside primary containment are described in this standard. Qualifications required by... | |
| Recommendations are provided for selection, 1 application, and installation of electrical power, signal, control, data, and specialty marine cable systems on shipboard. | |
| Recommendations for the design of electrical power generation, distribution, propulsion, loads systems and equipment on merchant, commercial and naval vessels | |
| Recommendations for the design, selection, and installation of switchboards onmerchant vessels with electrical apparatus for lighting, signaling, communication, power, andpropulsion are provided. | |
| Recommendations for the grouping of ships and their predominant mission systems to define and highlight unique features and requirements of a ship’s electrical power system driven by the ship’s mission... | |
| Recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of vented lead-acid batteries are provided. Required safety practices are also included. These recommended practices... | |
| Recommended practices for evaluating and measuring the performance of IEEE Std 802.11 Wireless Local Area Network (WLAN) devices and networks at the component and application level are described. A set... | |
| Review and update the definitions of excitation systems terminology, and the supporting bibliography and figures of typical excitation system configurations. | |
| Safe and reliable methods for the electrical protection of telecommunication facilities serving electric supply locations through the use of metallic wire-line components in part of thetelecommunication circuit and optical fiber... | |
| Safe and reliable methods for the electrical protection of telecommunication facilities serving electric supply locations through the use of optical fiber systems for the entire facility are presented in this... | |
| Seismic design recommendations for substations, including qualification of different equipment types are discussed. Design recommendations consist of seismic criteria, qualification methods and levels, structural capacities, performance requirements for equipment operation,... | |
| Specific test requirements for qualifying electrical resistance trace heating for commercial service. A basis for electrical and thermal design is included. Heating device characteristics are addressed, and installation and maintenance... | |
| Specific testing requirements for qua 30 lifying electrical resistance heating cables and heating devices for use in industrial applications, as well as a basis for electrical and thermal design, are... | |
| Specific testing requirements for qualifying electrical resistance trace heating for use in industrial applications in ordinary locations, as well as a basis for electrical and thermal design, are included in... | |
| Specific testing requirements for qualifying electrical resistance trace heating for use inindustrial applications in ordinary locations, as well as a basis for electrical and thermal design,are included in this standard. | |
| Specification and test requirements for a non-gyroscopic inertial angular sensor which may measure angular jerk, acceleration, rate or displacement with or without response down to zero frequency. A standard specification... | |
| Standard Docs | |
| Std. 404-2000, IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2 500v to 500 000v, will be revised to incorporate: 1) design tests for joint environmental seals; | |
| Technical corrections are addressed in this corrigendum. (NOTE: This corrigendum was not published as an individual standard. It was incorporated into IEEE Std 738-2012 at the time of publication) | |
| Terms and definitions relating to inertial sensors are presented in this standard. Usage as understood by the inertial sensor community is given preference over general technical usage of the terms... | |
| The C62.42 guide series covers surge protective components (SPCs) used in power and telecom surge protective devices (SPDs) and equipment ports. This part on Gas Discharge Tube (GDT) technology SPCs... | |
| The criteria for the application and testing of diesel-generator units as Class 1E standby power supplies in nuclear power generating stations are described in this standard. | |
| The criteria for the application and testing of diesel-generator units as Class 1E standby power supplies in nuclear power generating stations are described. | |
| The design criteria of the preferred power supply (PPS) and its interfaces with the Class 1E power system, switchyard, transmission system, and alternate ac (AAC) source are described. This standard... | |
| The design, installation, and protection of wire and cable systems in substations are covered in this guide, with the objective of minimizing cable failures and their consequences. | |
| The generation and practical use of medical three-dimensional (3D) modeling for diagnostics and therapeutic applications is described in this standard. Volume rendering and surface rendering techniques for 3D reconstruction from... | |
| The IEEE 802.11™ directional multi-gigabit (DMG) physical layer (PHY) and the medium access control (MAC) layer are modified by this amendment to IEEE Std 802.11™-2016 to enable operation in the... | |
| The IEEE 802.11(TM) directional multi-gigabit (DMG) physical layer (PHY) and the medium access control (MAC) layer are modified by this amendment to IEEE Std 802.11(TM)-2016 to enable operation in the... | |
| The independence requirements of the circuits and equipment comprising or associated with Class 1E systems are described in this standard. Criteria for the independence that can be achieved by physical... | |
| The independence requirements of the circuits and equipment comprising or associated with Class 1E systems are described. Criteria for the independence that can be achieved by physical separation and electrical... | |
| The inductive environment that exists in the vicinity of electric power and wire-line telecommunications systems and the interfering effects that may be produced are addressed. An interface that permits either... | |
| The measurement of thermal resistivity of soil and backfill materials to include concrete, engineered backfills, grout, rock, sand, and any other material used to encase the cable system installed in... | |
| The most common shield/sheath-bondin g systems now in use on medium through extra high-voltage (5 kV to 500 kV) single-conductor shielded power cables and the methods ofcalculating the corresponding shield/sheath... | |
| The promotion of clarity and consistency in the use of radar terminology is the purpose of the definitions provided in this guide. The consensus of a panel of radar experts... | |
| The purpose of the amendment is to improve the 802.11 wireless local area network (LAN) user experience by providing significantly higher basic service set (BSS) throughput for existing WLAN application... | |
| The purpose of the amendment is to improve the 802.11 wireless local area network(LAN) user experience by providing significantly higher basic service set (BSS) throughput forexisting WLAN application areas and... | |
| The purpose of this amendment is to improve the IEEE 802.11 wireless local area network (WLAN) user experience by providing significantly higher basic service set (BSS) throughput for existing WLAN... | |
| The purpose of this amendment is to improve the IEEE 802.11(tm) wireless local area network (WLAN) user experience by providing significantly higher basic service set (BSS)throughput for existing WLAN application... | |
| The purpose of this amendment is to incorporate all the technical corrections and changes to improve the document after RevCom has approved it. This will provide a correct and more... | |
| The recommendations for controls, control applications, control apparatus, and automation on shipboards are established by this document. These recommendations reflect the present-day technologies, engineering methods, and engineering practices. This document... | |
| The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated, dielectric-insulated power cable systems rated 5 kV to 500 kV are presented in this guide. | |
| The scope is the correction of Figure 1, Figure 2, Figure A. 1 and Figure B.1 of IEC/IEEE 62582-2:2011. | |
| The scope of the project is to cover measurements of the electrical properties of naturally occurring solids. Not covered are methods which rely on mapping earth structure anomalies unless directly... | |
| The scope of this project are enhancements to the 802.11 Medium Access Control (MAC) layer to minimize or eliminate the amount of time data connectivity between the Station (STA) and... | |
| The scope of this standard is to define the methodology for the application of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption... | |
| The standard applies to wires and cables, used principally for power system communications and control purposes, which are located within electric supply locations or are installed within the zone of... | |
| The Standard for Industrial Hard Real-Time Communication is an adoption of the EPSG DS 301--Ethernet POWERLINK--Communica tion Profile Specification. Ethernet POWERLINK is a communication profile for Real-Time Ethernet (RTE). It... | |
| The Standard Letter Designations for Radar-Frequency Bands was first issued in 1976 and was written to remove the confusion that developed from the misapplication to radar of letter band designations... | |
| The standard provides criteria for the performance of periodic surveillance testing of nuclear power generating station safety systems. The scope of periodic surveillance testing consists of functional tests and checks,... | |
| The world is witnessing a rapid advance in stereoscopic 3D (S3D), and ultra-highdefinition (UHD) technology. As a result, the need for accurate quality and visual-comfort assessment techniques to foster the... | |
| This amendment defines mechanisms that provide IEEE Std 802.11 networks with fastinitial link setup methods that do not degrade the security offered by Robust Security NetworkAssociation (RSNA) already defined in... | |
| This amendment defines modifications to both the 802.11 physical layers (PHY) and the 802.11 Medium Access Control Layer (MAC) so that modes of operation can be enabled that are capable... | |
| This amendment defines modifications to both the 802.11 physical layers (PHY) and the 802.11 Medium Access Control Layer (MAC) to enable operation in the 60 GHz frequency band capable of... | |
| This amendment defines modifications to both the IEEE 802.11 physical layer (PHY) and the medium access control (MAC) sublayer for high efficiency operation in frequency bands between 1 GHz and... | |
| This amendment defines modifications to both the IEEE 802.11 physical layer (PHY) and the medium access control (MAC) sublayer for wake-up radio operation. | |
| This amendment defines modifications to both the IEEE 802.11 physical layer (PHY) and the medium access control (MAC) sublayer to enable operation of license-exempt 802.11 wireless networks in frequency bands... | |
| This amendment defines modifications to the IEEE P802.11ad Physical (PHY) layer and the Medium Access Control (MAC) layer to enable operation in the Chinese millimeter wave frequency band at around... | |
| This amendment defines standardized modifications to both the IEEE 802.11 physical layers (PHY) and the IEEE 802.11 medium access control layer (MAC) that enables at least one mode of operation... | |
| This amendment is based on the current edition of IEEE Std 802.11, 1999 (Reaff 2003) Edition and IEEE Std 802.11g, 2003 and IEEE Std 802.11h, 2003. Defines the MAC procedures... | |
| This amendment provides a mechanism for prioritization of management frames and specifies a protocol to communicate management frame prioritization policy. | |
| This amendment specifies enhancements to the 802.11 MAC (Medium Access Control) for robust audio video streaming, while maintaining co-existence with other types of traffic. | |
| This amendment specifies the extensions to IEEE Std 802.11 for Wireless Local Area Networks providing mechanisms for Radio Resource Measurement. | |
| This amendment specifies the extensions to IEEE Std 802.11 for Wireless Local Area Networksproviding wireless communications while in a vehicular environment. | |
| This amendment specifies the extensions to IEEE Std 802.11® for Wireless Local Area Networks providing mechanisms for Radio Resource Measurement. | |
| This amendment specifies the extensions to IEEE Std 802.11¿ for Wireless Local Area Networks providing wireless communications while in a vehicular environment | |
| This amendment specifies the extensions to IEEE Std 802.11™ for Wireless Local Area Networks providing wireless communications while in a vehicular environment. | |
| This amendment specifies the extensions to IEEE Std 802.11™ for Wireless Local Area Networks providing wireless communications while in a vehicular environment | |
| This application guide covers procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V. The breaking capability limits... | |
| This document complements the architecture-related processes identified in ISO/IEC/IEEE 15288, ISO/IEC/IEEE 12207, and ISO 15704 with activities and tasks that enable architects and others to more effectively and efficiently implement... | |
| This document defines enhancements to the 802.11 PHYs and MAC to support operation in the TV bands white spaces. | |
| This document describes qualification methods for Class 1E lead storage batteries and racks to be used in nuclear power generating stations outside of primary containment. Qualification required in IEEE Std. | |
| This document is a guide for the design, installation , and protection of wire and cable systems in substations with the objective of minimizing cable failures and their consequences. | |
| This document is intended to serve as basic reference for the specification and design of field discharge circuits for synchronous machines. It is also intended to provide detailed information about... | |
| This document provides standard and recommended practices for ensuring the quality of measured data for high frequency electrical interconnect at bandwidths up to 50 GHz. This might include but is... | |
| This guide covers the measurement of thermal resistivity of soil and backfill materials to include concrete, engineered backfills, grout, rock, sand and any other material used to encase the cable... | |
| This guide describes the dc voltage tests procedures for the measurement of theinsulation resistance and polarization index of insulated stator and rotor windings and how tointerpret the results. | |
| This guide describes the most common sheath-bonding systems now in use on high voltage single-conductor shielded power cables and the methods of calculating sheath voltages and currents, particularly as applied... | |
| This guide describes very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems. Whenever possible,... | |
| This guide encompasses the application of surge protective devices (secondary arresters) fromthe secondary terminals of the distribution transformer to the line side of the service equipment. | |
| This Guide includes cable and raceway systems for fossil fuel electric generating stations and the portions of nuclear generating stations that are not “nuclear safety related”. | |
| This guide includes criteria, definitions, and test procedures for evaluating the dynamic performance of excitation control systems for synchronous machines as applied by electric utilities. | |
| This guide is intended to provide to the specification writer the information to prepare a specification for the purchase of an excitation system. This guide is presented in narrative form... | |
| This guide lists the various field test methods that are currently available or under development. The guide covers shielded, insulated power cable systems rated 5 kV and above. The guide... | |
| This Guide provides general and specific recommendations on specification, design and application of liquid-immersed and dry-type transformers in Distributed Photovoltaic (DPV) Power Generation Systems for commercial, industrial and utility systems. | |
| This insulation maintenance guide is applicable to rotating electric machines rated from 35 KVA and higher. The procedures detailed herein may also be useful for insulation maintenance of other types... | |
| This international standard (standard) describes HVSC systems, on board the ship and on shore, to supply the ship with electrical power from shore. This standard is applicable to the design,... | |
| This International Standard addresses the creation, analysis and sustainment of architectures of systems through the use of architecture descriptions. A conceptual model of architecture description is established. The required contents... | |
| This International Standard applies to outdoor and indoor bushings of any voltage used on d.c. systems, of capacitance graded or gas insulated types for use as components of oil-filled converter... | |
| This International Standard contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using tensile elongation techniques in the detail necessary to produce accurate and... | |
| This International Standard contains methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using the indenter modulus technique in the detail necessary to produce accurate... | |
| This International Standard contains requirements for application of the IEC/IEEE 62582- series of methods for condition monitoring in electrical equipment important to safety of nuclear power plants. It also includes... | |
| This International Standard IEC/IEEE 62704-3 describes the concepts, techniques, benchmark phone models, validation procedures, uncertainties and limitations of the finite difference time domain (FDTD) technique when used for determining the... | |
| This International Standard IEC/IEEE 62704-3 describes the concepts, techniques, phone models, validation procedures, uncertainties and limitations of the finite difference time domain (FDTD) technique when used for determining the peak... | |
| This part of IEC 60079 specifies general and testing requirements for electrical resistance trace heaters for application in explosive gas atmospheres. The standard covers trace heaters that may comprise either... | |
| This part of IEC 61850 specifies a precision time protocol (PTP) profile of IEC 61588:2009, IEEE Std 1588-2008 applicable to power utility automation which allows compliance with the highest synchronization... | |
| This part of IEC 62271 applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages... | |
| This part of IEC 62271 is applicable to three-phase a.c. high-voltage generator circuitbreakers,here after called generator circuit-breaker, designed for indoor or outdoor installationand for operation at frequencies of 50 Hz... | |
| This part of IEC/IEEE 62582 specifies methods for condition monitoring of organic and polymeric materials in instrumentation and control systems using oxidation induction techniques in the detail necessary to produce... | |
| This part of IEC/IEEE 62704 defines the methodology for the application of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (SAR)... | |
| This project will define Radio Resource Measurement enhancements to provide interfaces to higher layers for radio and network measurements. | |
| This project will present the fundamentals of reliability analysis that should be used in planning, designing and operating reliable industrial and commercial power systems. The reliability fundamentals would include: probability... | |
| This recommended practice 1 describes very low frequency (VLF) withstand and diagnostic tests that are performed on the stator windings of ac electric machines | |
| This recommended practice covers electrical safety considerations for shipboard electrical systems and equipment including a review of fundamental concepts pertaining to electrical safety and establishing electrical safety programs and work... | |
| This recommended practice describes very low frequency (VLF) withstand and diagnostic tests that are performed on the stator windings of ac electric machines | |
| This recommended practice intends to establish goals for the design of electrical systems that include both linear and nonlinear loads. The voltage and current waveforms that may exist throughout the... | |
| This recommended practice presents engineering design practices for special high-voltage protection systems intended to protect wire-line telecommunication facilities serving electric supply locations. The following topics are included in this document:... | |
| This recommended practice provides 1 considerations for the pre-installation, installation, inspection, and testing of Class 1E power, instrumentation, and control equipment and systems of a nuclear facility while in the... | |
| This revision specifies technical corrections and clarifications to IEEE 802.11-1999 as reaffirmed in 2003 for wireless local area networks (WLANS) as well as enhancements to the existing MAC and PHY... | |
| This revision specifies technical corrections and clarifications to IEEE Std 802.11 for wireless local area networks (WLANS) as well as enhancements to the existing medium access control (MAC) and physical... | |
| This revision specifies technical corrections and clarifications to IEEE Std 802.11 forwireless local area networks (WLANS) as well as enhancements to the existing medium accesscontrol (MAC) and physical layer (PHY)... | |
| This standard applies to the avalanche breakdown diodes used for surge protection on systems with voltages equal to or less than 1000 V rms or 1200 V dc. The avalanche... | |
| This standard covers means of safeguarding personnel while operating or maintaining equipment located in electrolytic cell line working zones.Included are related requirements for equipment and electrical conductor installations. The general... | |
| This standard covers the requirements for phase-shifting transformers of all types. The scopeexcludes transformers with a fixed unregulated phase shift.This standard is limited to matters particular to phase-shifting transformers and... | |
| This standard describes qualification methods for Class 1E vented lead acid batteries and racks to be used in nuclear power generating stations outside primary containment. Qualification required by IEEE Std... | |
| This standard describes qualification methods for Class 1E vented lead acid batteries andracks to be used in nuclear power generating stations outside primary containment. Qualificationrequire d by IEEE Std 308(TM)... | |
| This standard describes the concepts, techniques, vehicle models, validation procedures, uncertainties and limitations of the finite-difference time-domain technique (FDTD) when used for determining the spatial-peak specific absorption rate (SAR) in... | |
| This standard describes the generation and practical use of medical three-dimensional (3D) modeling for diagnostics and therapeutic applications. It includes volume rendering and surface rendering techniques for 3D reconstruction from... | |
| This standard establishes requirements for initiating, planning, controlling, and executing the Software Quality Assurance processes of a software development or maintenance project. This standard is harmonized with the software life... | |
| This standard establishes uniform procedures for the measurement of radio noise generated by corona from overhead power lines and substations. Measurement procedures in this standard are also valid for other... | |
| This standard is applicable to electrical equipment important to safety and its interfaces thatare necessary to perform a safety function, or whose failure could adversely affect, the safetyfunctions of other... | |
| This standard is applicable to three-phase a.c. high-voltage generator circuit breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and... | |
| This standard is to be read in conjunction with IEC 62271-1:20xx17, to which it refers and which is applicable unless otherwise specified in this standard. In order to simplify the... | |
| This standard presents engineering design procedures for the electrical protection of communication facilities serving electric supply locations through the use of neutralizing transformers. | |
| This standard presents safe and reliable methods for the electrical protection of telecommunication facilities serving electric supply locations through the use of metallic wire-line components in part of the telecommunication... | |
| This standard presents safe and reliable methods for the electrical protection of telecommunication facilities serving electric supply locations through the use of optical fiber systems for the entire facility. | |
| This standard provides a framework for introducing nanomaterials such as graphene into large scale, high volume manufacturing in established semiconductor factories (fabs). Since semiconductor fabs must incorporate practices that maintain... | |
| This standard provides continuation and further development of previous synchrophasor standards, notably the IEEE C37.118 series. It defines synchrophasor, frequency, and rate of change of frequency (ROCOF) measurements as used... | |
| This standard provides continuation and further development of previous synchrophasor standards,notably the IEEE C37.118 series. It defines synchrophasor, frequency, and rate of change offrequency (ROCOF) measurements as used in this... | |
| This standard provides criteria for qualification of commonly- used Class 1E connection assemblies for service in nuclear power generating stations. The proposed revision will address (1) current qualification methodology and... | |
| This standard provides direction for the design and installation of safety-related electrical cable systems, including associated circuits, in nuclear power generating stations. Also provided is guidance for the design, installation... | |
| This standard provides general requirements and methods for qualifying electric cables, and splices for nuclear facilities. Cable, wire, and splices within or integral to other devices (e.g., instruments, panels, motors,... | |
| This standard provides guidance on basic 1 qualification principles and appropriate methods of demonstrating the qualification of equipment used in nuclear facilities. The principles, methods, and procedures described are intended... | |
| This standard provides guidance on basic qualification principles and appropriate methods of demonstrating the qualification of equipment used in nuclear facilities. The principles, methods, and procedures described are intended to... | |
| This standard provides requirements for the application of the single-failure criterion to the electrical power, instrumentation, and control portions of nuclear power generating safety systems. | |
| This standard provides test procedures and requirements for all indoor and outdoor cable terminations used on alternating-current shielded cables having laminated insulation rated 2.5 kV through 765 kV and extruded... | |
| This standard provides the principal design criteria, design features, and testing requirements for the protection of Class 1E power systems and equipment supplied from those systems. It identifies special protection... | |
| This standard sets forth the minimum acceptable requirements for the performance of reliability analyses for safety systems when used to address the reliability considerations discussed in industry standards and guidelines. | |
| This standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance, interchangeability, and safety of the equipment covered and... | |
| This standard specifies interchange and arithmetic formats and methods for binary and decimal floating-point arithmetic in computer programming environments. Exception conditions are defined and default handling of these conditions is... | |
| This standard specifies interchange and arithmetic formats and methods for binary and decimal floating-point arithmetic in computer programming environments. This standard specifies exception conditions and their default handling. An implementation... | |
| This standard specifies the design requirements for new and/or modified Class 1E control boards, panels, and racks and establishes the methods to verify that these requirements have been satisfied. Methods... | |
| To provide a recommended practice for the design and operation of electric systems in health care facilities. The term health care facility, as used here, encompasses buildings or parts of... | |
| Uniform procedures are established for manual and automatic measurement of audible noise from overhead transmission lines. Their purpose is to allow valid evaluation and comparison of the audible noise performance... | |
| Uniform procedures for the measurement of power frequency electric and magnetic fields from alternating current (ac) overhead power lines and for the calibration of the meters used in these measurements... | |
| Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. | |
| Workable methods for protecting wire-line telecommunication circuits entering electric supply locations are presented. This document covers: the electric supply location environment; protection apparatus; service types, reliability, service performance objective classifications,... |
| << Prev | Next >> |