ASTM International Datasheets for Standards and Technical Documents

Standards and technical documents includes standards, codes, regulation, handbooks, manuals, comprehensive guides and other formal publications. Standards, codes, and regulation establish uniform specifications, procedures or technical criteria.
Standards and Technical Documents: Learn more

Page: 1 10 20 30 31 32 33 34 35 36 37 38 39 40 41 42 50 60 70 80 90 100 150 182
Product Name Notes
1.1 A sample of spent nuclear fuel is analyzed to determine the quantity and atomic ratios of uranium and plutonium isotopes, neodymium isotopes, and selected gamma-emitting nuclides (137Cs,...
1.1 Intent: 1.1.1 The intent of this guide is to provide general considerations for the development, verification, validation, and documentation of tank simulants for hazardous materials (for example, radioactive wastes)...
1.1 Intent: 1.1.1 The intent of this guide is to provide guidance for the measurement and calculation of physical and rheological properties of radioactive solutions, slurries, and sludges as well...
1.1 Intent: 1.1.1 The intent of this guideline is to provide general considerations for the development, verification, validation, and documentation of high-level waste (HLW) tank simulants. Due to the expense...
1.1 The non-destructive procedure described in this practice induces a depression (strain) in the sealant, creating an elongation of the sealant and a stress on the adhesive bond at the...
1.1 These test methods cover procedures for determining the tensile strength of a section of portland cement-based plaster, the bond strength between portland cement-based plaster and a solid plaster base,...
1.1 These test methods describe three bench top test methods for measuring the thermophysical responses of gypsum boards and panels when exposed to high temperatures. The test methods are: 1.1.1...
1.1 These test methods evaluate the performance of non metallic plaster bases used with Portland cement based plaster under a variety of test exposures. 1.2 Units\u2014The values stated in either...
1.1 These test methods evaluate the performance of vertical wall applications of non metallic plaster bases used with Portland Cement Based Plaster under a variety of test exposures. 1.2 Units-The...
1.1 These test methods evaluate the performance of vertical wall applications of non metallic plaster bases used with Portland cement based plaster under a variety of test exposures. 1.2 Units\u2014The...
1.1 This classification covers fiber reinforced carbon-carbon (C-C) composite structures (flat plates, rectangular bars, round rods, and tubes) manufactured specifically for structural components. The carbon-carbon composites consist of carbon/graphite fibers...
1.1 This classification covers silicon carbide-silicon carbide (SiC-SiC) composite structures (flat plates, rectangular bars, round rods, and tubes) manufactured for structural components. The SiC-SiC composites consist of continuous silicon carbide...
1.1 This document is a guide to preparing material specifications for fiber reinforced carbon-carbon (C-C) composite structures (flat plates, rectangular bars, round rods, and tubes) manufactured specifically for structural components...
1.1 This document is a guide to preparing material specifications for silicon carbide fiber/silicon carbide matrix (SiC-SiC) composite structures (flat plates, rectangular bars, round rods, and tubes) manufactured specifically for...
1.1 This guide addresses techniques used to obtain grab samples from tanks containing high-level radioactive waste created during the reprocessing of spent nuclear fuels. Guidance on selecting appropriate sampling devices...
1.1 This guide addresses techniques used to obtain samples from tanks containing high-level radioactive waste created during the reprocessing of spent nuclear fuels. Guidance on selecting appropriate sampling devices for...
1.1 This guide covers description of several methods to measure the rheological properties of fresh hydraulic cement paste. All methods are designed to determine the yield stress and plastic viscosity...
1.1 This guide covers methods for reducing efflorescence potential in new unit pavement systems. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI...
1.1 This guide covers sampling, selection, preparation, and conditioning of specimens that will be used to test material properties of dimension stone. 1.2 This guide sets forth basic recommendations for...
1.1 This guide covers the general effects of temperature during the use temperatures for aerosol foam sealant (either polyurethane or latex types). 1.2 The guide is intended to estimate the...
1.1 This guide covers the general effects of temperature during the use temperatures for aerosol foam sealant (either polyurethane or latex types). 1.2 The guide is intended to estimate the...
1.1 This guide covers the general effects of temperature from the aerosol foam sealant (either polyurethane or latex types) under the use temperatures. 1.2 The guide is intended to estimate...
1.1 This guide covers the general use of aerosol polyurethane and aerosol latex foams extruded from pressurized containers intended for building envelope air barrier sealant and adhesive applications in building...
1.1 This guide describes passive neutron measurement methods used to nondestructively estimate the amount of neutron-emitting special nuclear material compounds remaining as holdup in nuclear facilities. Holdup occurs in all...
1.1 This guide describes the steps for developing improved laboratory accelerated weathering tests for predicting the natural weathering effects on building sealant systems and for using those tests in development...
1.1 This guide identifies appropriate test methods for determining the sufficiency of radiological shielding for hot cells and shielded enclosures. 1.2 After constructing or modifying radiological shielding, it is necessary...
1.1 This guide is intended to assist in establishing procedures for determining the relative abrasion resistance of treated or untreated mortar surfaces. 1.2 This guide utilizes the rotary platform abraser,...
1.1 This guide provides general guidance for developing ASTM unit specification for masonry units manufactured with constituent materials, manufacturing methods, and combinations thereof, that are not included in a current...
1.1 This guide provides guidance on how to address the potential for deleterious alkali aggregate reaction (AAR) in concrete construction. This guide addresses the process of identifying both potentially alkali-silica...
1.1 This guide provides information for the laboratory measurement of the steady-state thermal transmission properties and heat flux of thermal insulation systems under cryogenic conditions. Thermal insulation systems may be...
1.1 This guide provides information on how to compare the relative performance and potential incompatibility of combinations of concrete-making materials. Performance tests on fresh and early-age properties of mortar mixtures...
1.1 This guide provides photographs that illustrate seal and sealant behavior consistent with the scope and areas of interest of Committee C24. 1.2 When available, photographs that better illustrate these...
1.1 This guide provides photographs that illustrate sealant behavior terms that have been defined by Committee C24. 1.2 When available, photographs that better illustrate these terms, or that illustrate additional...
1.1 This guide provides photographs that illustrate sealant behavior terms that have been defined by Committee C24. 1.2 When available, photographs that better illustrate these terms, or that illustrate additional...
1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and...
1.1 This performance based specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts. 1.2...
1.1 This practice covers a procedure for measuring and monitoring the physical dimensions of an elastomeric joint sealant in a test specimen configuration described in Test Method C719 following a...
1.1 This practice covers a procedure for quantitatively determining the extent of cracking in a sealant sample by evaluating the difference between the measured compressive and tensile modulus of a...
1.1 This practice covers procedures for fabricating and testing specimens in the laboratory and the field using a representative sample of ultra-high performance concrete (UHPC), for the purpose of determining...
1.1 This practice covers procedures for fabricating test specimens in the laboratory or field using a representative sample of fresh self-consolidating concrete (SCC). This practice is applicable to SCC with...
1.1 This practice covers procedures for obtaining representative samples of fresh concrete as delivered to the project site on which tests are to be performed to determine compliance with quality...
1.1 This practice covers procedures for sampling and for the amount of testing of hydraulic cement after it has been manufactured and is ready to be offered for sale. 1.2...
1.1 This practice covers procedures for sampling and for the amount of testing of hydraulic cement after it has been manufactured and is ready to be offered for sale. 1.2...
1.1 This practice covers the high-shear mixing of hydraulic cement pastes. 1.2 The values stated in SI units or inch-pound units are to be regarded as the standard. Within the...
1.1 This practice covers the high-shear mixing of hydraulic cement pastes. 1.2 The values stated in SI units or inch-pound units are to be regarded as the standard. Within the...
1.1 This practice covers the installation of concrete floor tile (CFT) units for application as exterior and interior flooring. Units described by this practice shall be manufactured to meet the...
1.1 This practice covers the installation of high-pressure spray polyurethane foam (SPF) as an insulation for building enclosure assemblies including: walls, ceilings, attics, floors, and crawl spaces. This practice does...
1.1 This practice covers the installation requirements of direct hung suspended t-bar type ceiling systems intended to receive gypsum panel products constructed as flat, single level, surrounded on all sides...
1.1 This practice covers the procedures to be followed in the planning, site preparation, installation, testing and backfilling of underground vertical reinforced circular precast concrete manholes and components manufactured in...
1.1 This practice covers the requirements for inspection and acceptance of installed reinforced concrete pipe by either person-entry, or remote inspection as shown in Figs. 1 and 2, respectively. 1.2...
1.1 This practice covers the requirements for inspection and acceptance of installed reinforced concrete pipe by either person-entry, or remote inspection as shown in Figs. 1 and 2, respectively. FIG.
1.1 This practice covers two procedures for making and curing cylindrical specimens of concrete under conditions that increase the rate of hydration at early ages. The procedures are: A-Warm Water...
1.1 This practice covers two procedures for making and curing cylindrical specimens of concrete under conditions that increase the rate of hydration at early ages. The procedures are: A\u2014Warm Water...
1.1 This practice describes the apparatus and procedure for evaluating relative differences in early hydration of hydraulic cementitious mixtures such as paste, mortar, or concrete, including those containing chemical admixtures,...
1.1 This practice has been prepared for use by the designer, specifier, builder, and the installer of radiant barrier systems (RBS) for use in (multi- and single-family) residential building construction,...
1.1 This practice has been prepared for use by the designer, specifier, builder, and the installer of radiant barrier systems (RBS) for use in commercial/industria l building construction not otherwise...
1.1 This practice is an alternative method to Test Method C698 for the determination of the oxygen-to-metal atom ratio (O/M) in sintered mixed oxide fuel (MOX) pellets. The method presented...
1.1 This practice is an alternative to Practice C1411 for the ion exchange separation in small mass samples (~5 μg of plutonium and up to 0.5 mg of uranium in...
1.1 This practice is intended to provide accepted procedures to designers and installers of adhered manufactured stone masonry veneer in residential and commercial construction. This information is meant to complement...
1.1 This practice is intended to provide accepted procedures to designers and installers of cement-based adhered masonry veneer in residential and commercial construction. This information is meant to complement the...
1.1 This practice prescribes the design of journal-bearing type rollers to support each end of fiber-reinforced concrete beams tested using Test Method C1399/C1399M or Test Method C1609/C1609M. The roller design...
1.1 This practice presents a laboratory guide to determine the thermal resistance of loose-fill building insulations installed in side walls behind netting at mean temperatures between -10 and 35°C (14...
1.1 This practice presents a laboratory guide to determine the thermal resistance of pneumatically installed loose-fill building insulations for enclosed applications of the building thermal envelope behind netting at mean...
1.1 This practice provides a description of the different ways to clean uranium hexafluoride (UF6) bottles. 1.2 This practice describes two kinds of sample bottles: 1S and 2S...
1.1 This practice provides instruction for the preparation of test specimens of pressure sensitive adhesive (psa) sealed joints of the type employed in insulation vapor retarder systems, for subsequent testing...
1.1 This practice provides instructions for the rapid separation of lanthanide elements using high pressure ion chromatography (HPIC) from dissolved uranium materials such as: nuclear fuels, uranium ores, hydrolyzed UF...
1.1 This practice provides the procedure for using the impulse-response method to evaluate rapidly the condition of concrete slabs, pavements, bridge decks, walls, or other plate-like structures. 1.2 The values...
1.1 This practice provides the procedure for using the impulse-response method to evaluate rapidly the condition of concrete slabs, pavements, bridge decks, walls, or other plate-like structures. 1.2 The values...
1.1 This specification addresses the minimum performance for flexible laminate protective jacket and a pressure sensitive adhesive tape for use over thermal insulation on pipes, duct, and equipment operating at...
1.1 This specification applies to ground calcium carbonate (GCC is a type of ground limestone) and other finely divided aggregate mineral filler (AMF) materials for use in concrete mixtures. The...
1.1 This specification applies to the minimum installation requirements for non metallic plaster bases used with portland cement based plaster in vertical wall applications. 1.2 Where a fire resistance rating...
1.1 This specification contains the minimum requirements for lathing and furring accessories, and fasteners, as components of interior and exterior portland cement-based plaster assemblies, used to facilitate lathing and furring...
1.1 This specification covers aluminum jacketing for thermal and acoustical insulation operating at either above or below ambient temperatures and in both indoor and outdoor locations. It does not cover...
1.1 This specification covers direct buried underground pre-insulated, hot water piping systems with an upper temperature limit of 250 °F (121 °C) used to convey pressurized fluids for district heating.
1.1 This specification covers fly ash brick intended for use in masonry, which are made from fly ash, water, and suitable mineral aggregates with or without the inclusion of other...
1.1 This specification covers insulating covers for use on exposed drain and water supply piping under accessible lavatories and sinks. The insulating covers shall have thermal insulating properties to protect...
1.1 This specification covers lightweight aggregate intended to provide water for internal curing of concrete. It includes test methods for determining the absorption and desorption properties of lightweight aggregate. Note...
1.1 This specification covers lightweight aggregate intended to provide water for internal curing of concrete. It includes test methods for determining the absorption and desorption properties of lightweight aggregate. Note...
1.1 This specification covers precast reinforced concrete box sections comprised of separate segments that once properly field assembled make the final structure. These structures are intended to be used for...
1.1 This specification covers returned fresh concrete for use in a new batch of ready-mixed concrete. Requirements for returned fresh concrete shall be either as hereinafter specified or as specified...
1.1 This specification covers spun cast prestressed concrete bases used in lighting structures. 1.2 Units-The values stated in SI units are to be regarded as standard.
1.1 This specification covers stainless steel jacketing for thermal, acoustical, and fire protective insulation operating at either above or below ambient temperatures and in both indoor and outdoor locations. It...
1.1 This specification covers steel fiber reinforced concrete pipe (SFRCP) of internal diameters 12 - 48 in., intended to be used for the conveyance of sewage, industrial wastes, and storm...
1.1 This specification covers synthetic fiber reinforced concrete pipe (Syn-FRCP) of internal diameters 12-48 in., intended to be used for the conveyance of sewage, industrial wastes, and storm water and...
1.1 This specification covers the classification, composition, and physical properties of an Interior Radiation Control Coating (IRCC) for use in building applications to reduce radiant heat transfer. The IRCC is...
1.1 This specification covers the design, testing, manufacture, selection, and installation of fabricated metal access hatches for utility, water, and wastewater structures including utility vaults, drainage structures, valve vaults, meter...
1.1 This specification covers the production of dry cast concrete as defined in 3.2.1. Requirements for quality of concrete shall be as hereinafter specified. This specification does not cover the...
1.1 This specification covers the production of dry cast concrete as defined in 3.2.1. Requirements for quality of concrete shall be either as hereinafter specified or as specified by the...
1.1 This specification covers the requirements for segmental concrete paving slabs manufactured for construction of pedestrian and roof applications for commercial and municipal projects where close dimensional tolerances for thickness,...
1.1 This specification covers wet-cast precast modular retaining wall units cast from first-purpose concrete with or without the inclusion of steel reinforcement. The precast units covered by this specification are...
1.1 This standard provides the minimum specification for use of non metallic plaster bases with portland cement based plaster in vertical wall applications. 1.2 Units-The values stated in either SI...
1.1 This test method applies to the calibration of hand-held moisture meters for gypsum board, glass faced gypsum panels and fiber-reinforced gypsum panels by means of electrical conductance and dielectric...
1.1 This test method applies to the calibration of handheld moisture meters for gypsum board, glass faced gypsum panels and fiber-reinforced gypsum panels by means of electrical conductance and dielectric...
1.1 This test method concerns measurement of selected hydraulic characteristics of hydrodynamic separators and underground settling devices critical to their function as stormwater treatment devices. 1.2 Units tested shall be...
1.1 This test method concerns measurement of selected hydraulic characteristics of hydrodynamic separators and underground settling devices critical to their function as stormwater treatment devices. 1.2 Units tested shall be...
1.1 This test method concerns measurement of the efficiency of hydrodynamic separators and underground settling devices in removing suspended sediment from simulated stormwater runoff under conditions defined herein. This test...
1.1 This test method covers a procedure for measuring the time dependence of modulus in elastomeric joint sealants in a test specimen configuration described in Test Method C719. These sealant...
1.1 This test method covers determination of the air content of freshly mixed concrete containing any type of aggregate, whether it be dense, cellular, or lightweight. 1.2 The values stated...
1.1 This test method covers determination of the air content of freshly mixed concrete containing any type of aggregate, whether it be dense, cellular, or lightweight. 1.2 The values stated...
1.1 This test method covers determination of the fineness of hydraulic cement by means of the 150-[mu]m (No. 100) and 75-[mu]m (No. 200) sieves. 1.2 This standard does not purport...
1.1 This test method covers determination of ultimate bending moment capacity and cracking moment capacity of concrete bases used as foundations for tapered steel lighting poles in accordance to Specification...
1.1 This test method covers determining the potential resistance to degradation of pervious concrete by measuring the mass loss of specimens subjected to combined action of impact and abrasion in...
1.1 This test method covers the achievement and measurement of steady-state heat flux through flat-slab specimens using a guarded-hot-plate apparatus. The method encompasses both the single-sided and the double-sided mode...
1.1 This test method covers the compaction of cylindrical specimens of roller-compacted concrete (RCC) using the gyratory compactor to determine density. 1.2 Units-The values stated in SI units or inch-pound...
1.1 This test method covers the determination of boron, silicon and technetium in hydrolyzed uranium hexafluoride (UF6) by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) after separation of the...
1.1 This test method covers the determination of boron, silicon, and technetium in hydrolyzed uranium hexafluoride (UF6) by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) after separation of the...
1.1 This test method covers the determination of density and air content of freshly mixed roller-compacted concrete (RCC) using the apparatus described in Test Method C231/C231M and the vibrating hammer...
1.1 This test method covers the determination of distribution coefficients of chemical species to quantify uptake onto solid materials by a batch sorption technique. It is a laboratory method primarily...
1.1 This test method covers the determination of distribution coefficients, Kd, of chemical species to quantify uptake onto solid materials by a batch sorption technique. It is a...
1.1 This test method covers the determination of hydrogen in nuclear-grade mixed oxides (MOX) of uranium and plutonium ((U, Pu)O2) sintered MOX fuel pellets. This test method is...
1.1 This test method covers the determination of hydrogen in nuclear-grade mixed oxides of uranium and plutonium ((U, Pu)O2) sintered fuel pellets. This test method is an alternative...
1.1 This test method covers the determination of particle size distribution of advanced ceramic powders. Experience has shown that this test method is satisfactory for the analysis of silicon carbide,...
1.1 This test method covers the determination of the air content of hydraulic cement mortar under the conditions hereinafter specified. 1.2 The values stated in SI units are to be...
1.1 This test method covers the determination of the air content of hydraulic cement mortar under the conditions hereinafter specified. 1.2 The values stated in SI units are to be...
1.1 This test method covers the determination of the bulk electrical conductivity of saturated specimens of hardened concrete to provide a rapid indication of the concrete's resistance to the penetration...
1.1 This test method covers the determination of the concentration of pinhole detections in a moisture barrier film or coating that is applied to the interior surface of metal jacketing.
1.1 This test method covers the determination of the drying shrinkage and of the combined drying and linear change of ramming and plastic refractories. 1.2 The values stated in inch-pound...
1.1 This test method covers the determination of the drying shrinkage and of the combined drying and linear change of refractory ramming mixes and plastics. 1.2 The values stated in...
1.1 This test method covers the determination of the drying shrinkage and of the combined drying and linear change of refractory ramming mixes and plastics. 1.2 The values stated in...
1.1 This test method covers the determination of the field surface infiltration rate of in place permeable unit pavement systems surfaced with solid interlocking concrete paving units, concrete grid paving...
1.1 This test method covers the determination of the heat of hydration of a hydraulic cement by measuring the heat of solution of the dry cement and the heat of...
1.1 This test method covers the determination of the hoop tensile strength including stress-strain response of continuous fiber-reinforced advanced ceramic tubes subjected to an internal pressure produced by the expansion...
1.1 This test method covers the determination of the slow crack growth (SCG) parameters of advanced ceramics in a given test environment at elevated temperatures in which the time-to-failure of...
1.1 This test method covers the determination of the thickness of a concrete pavement, slab, or structural element by measuring the length of a core drilled from a concrete structure.
1.1 This test method covers the determination of the thickness of a concrete pavement, slab, or structural element using drilled cores. 1.2 The text of this standard refers to notes...
1.1 This test method covers the determination of the thickness of a concrete pavement, slab, or structural element using drilling cores. 1.2 The values stated in either SI units or...
1.1 This test method covers the determination of the workability index of fireclay and high-alumina plastic refractories by measuring the plastic deformation of a molded test specimen when subjected to...
1.1 This test method covers the determination of the workability index of fireclay and high-alumina refractory plastics by measuring the plastic deformation of a molded test specimen when subjected to...
1.1 This test method covers the determination of uranium in urine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) after dilution in nitric acid. The method is presented in two parts.
1.1 This test method covers the determination of water ingress into the bulk (mass) of a hardened, dried concrete specimen after being submerged for 30 minutes. 1.2 The text of...
1.1 This test method covers the measurement of non-steady-state heat flow into or out of a flat slab specimen to determine the stored energy (that is, enthalpy) change as a...
1.1 This test method defines a procedure to determine the water absorption coefficient of a material by partial submersion. The scope is to evaluate the rate of absorption of water...
1.1 This test method describes a procedure for determining the flow rate of aerosol foam sealants. 1.2 Flow rate is determined in a controlled laboratory environment with manual dispensing (Method...
1.1 This test method describes the determination of the isotope amount ratios of uranium material as nitrate solutions by the modified total evaporation (MTE) method using a thermal ionization mass...
1.1 This test method determines the amount of water retained (excluding surface water) by flat or cylindrical specimens of thermal insulations after these materials have been fully immersed in liquid...
1.1 This test method determines the amount of water retained (excluding surface water) by flat specimens of thermal insulations after these materials have been fully immersed in liquid water for...
1.1 This test method determines the axial tensile strength and stress-strain response of continuous fiber-reinforced advanced ceramic composite tubes at ambient temperature under monotonic loading. This test method is specific...
1.1 This test method determines the mass loss over time due to one-dimensional drying and moisture transport in an initially saturated cylindrical specimen with both ends exposed to constant temperature...
1.1 This test method establishes the criteria for the laboratory measurement of the steady-state heat flux through flat, homogeneous specimen(s) when their surfaces are in contact with solid, parallel boundaries...
1.1 This test method for the determination of carbon in mixed oxide (MOX) pellets consists of combusting carbon with oxygen in a high-frequency induction furnace and subsequent detection of the...
1.1 This test method is an alternative to Test Method C698 for the determination of carbon in nuclear grade sintered mixed oxide (MOX) fuel pellets. The method for the determination...
1.1 This test method is designed to determine the bleed stability of freshly-mixed cementitious grout under static pressure. 1.2 The text of this standard refers to notes and footnotes that...
1.1 This test method is designed to determine the bleed stability of freshly-mixed cementitious grout under static pressure. 1.2 Units-The values stated in SI units are to be regarded as...
1.1 This test method is designed to determine the bleed stability of freshly-mixed cementitious grout under static pressure. 1.2 Units-The values stated in SI units are to be regarded as...
1.1 This test method is for the determination of the air-entraining admixture (AEA) demand of a mixture of cementitious materials, AEA, and water. 1.2 The values stated in SI units...
1.1 This test method is suitable for determining boron and silicon impurities as BF3 and SiF4 in uranium hexafluoride. This test method is an alternative to those described...
1.1 This test method is suitable for laboratory use to determine one or more of the following: 1.1.1 The bond strength of a repair or an overlay material to a...
1.1 This test method is used for determining the shear bond strength of dimension stone wall or floor assembly adhered to a substrate. 1.2 This test method was developed for...
1.1 This test method is used to determine compliance with Specification C967 for the requirements of moisture in uranium ore concentrates (UOC). A procedure is given to determine the approximate...
1.1 This test method provides a procedure for determining the density and void content of hardened pervious concrete specimens. 1.2 The values stated in either SI units or inch-pound units...
1.1 This test method provides a procedure for determining the density and void content of hardened pervious concrete specimens. 1.2 The values stated in either SI units or inch-pound units...
1.1 This test method provides a rapid test to determine the amount of methylene blue adsorbed by a specimen of fine aggregate or mineral filler and can be used both...
1.1 This test method specifies a method for the determination of loose and tapped bulk density of plutonium oxide (PuO2) powder. 1.2 This test method is applicable when...
1.1 This test method specifies a method for the determination of loose and tapped bulk density of plutonium oxide powder. 1.2 This test method is applicable when limited quantities of...
1.1 This test method specifies the determination of the volumetric uranium and plutonium concentrations, typically, in nitric acid solutions through the combination of K-Edge absorption Densitometry (KED) and K X-Ray...
1.1 This test method supplements Test Method C 201, and shall be used in conjunction with that test method to determine the thermal conductivity of insulating firebrick. 1.2 The values...
1.1 This test method supplements Test Method C201, and shall be used in conjunction with that test method to determine the thermal conductivity of insulating firebrick. 1.2 The values stated...
1.1 This test method supplements Test Method C201, and shall be used in conjunction with that test method to determine the thermal conductivity of insulating firebrick. 1.2 The values stated...
1.1 This test standard shall be used to determine the hydraulic characteristics of stormwater filtration elements. 1.2 Elements tested shall be of a size commonly manufactured, not a scale model.
Method of Panel Spalling Testing Fireclay Plastic Refractories (Withdrawn 1984)
Methods of Chemical Analysis of Refractory Materials (Withdrawn 1965)
Specification for Air-Setting Refractory Mortar (Wet Type) for Boiler and Incinerator Services (Withdrawn 1972)
Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus
This specification applies to stainless steel jacketing for thermal, acoustical, and fire protective insulation operating at either above or below ambient temperatures and in both indoor and outdoor locations. It...
This specification covers fly ash brick intended for use in masonry and made from fly ash, water, and suitable mineral aggregates with or without the inclusion of other materials, and...
This specification covers fly ash brick intended for use in masonry, which are made from fly ash, water, and suitable mineral aggregates with or without the inclusion of other materials,...
This specification covers ground calcium carbonate (GCC, a type of ground limestone) and other finely divided aggregate mineral filler (AMF) materials for use in concrete mixtures. It defines the types...
This specification covers precast reinforced concrete box sections comprised of separate segments that once properly field assembled make the final structure. These structures are intended to be used for the...
This specification covers requirements for returned fresh concrete for use in a new batch of ready-mixed concrete, as well as the requirements specified by the purchaser. If the requirements of...
This specification covers segmental concrete paving slabs manufactured for construction of pedestrian and roof applications for commercial and municipal projects where close dimensional tolerances for thickness, and/or length and width...
This specification covers spun cast prestressed concrete bases used in tapered steel lighting poles. It provides requirements for acceptability of spun prestressed concrete bases produced in accordance with this specification,...
This specification covers stainless steel jacketing for thermal, acoustical, and fire protective insulation operating at either above or below ambient temperatures and in both indoor and outdoor locations. It does...
This specification covers synthetic fiber reinforced concrete pipe (Syn-FRCP) of internal diameters 12-48 in., intended to be used for the conveyance of sewage, industrial wastes, and storm water and for...
This specification covers the design, testing, manufacture, selection, and installation of fabricated metal access hatches for utility, water, and wastewater structures including utility vaults, drainage structures, valve vaults, meter vaults,...
This specification covers the materials, manufacturing practice, and corresponding test methods for wet-cast precast modular retaining wall units cast from first-purpose concrete with or without the inclusion of steel reinforcement.
This specification covers the minimum requirements for lathing and furring accessories and fasteners used as components of interior and exterior portland cement-based plaster assemblies for facilitating lathing and furring installation,...
This specification describes the minimum requirements for the installation of non-metallic plaster bases used with portland cement-based plaster in vertical wall applications. In cases where a fire resistance rating is...
This specification describes the physical requirements for aluminum jacketing for thermal and acoustical insulation operating at either above or below ambient temperatures and in both indoor and outdoor locations. Insulation...
This specification establishes the product criteria and minimum performance requirements for concrete floor tile (CFT) used as interior and exterior flooring. The units described by this specification are manufactured from...
This specification establishes the requirements for factory-laminated gypsum panel products designed for use either on walls, ceilings, or partitions as part of a sound control system, or as a gypsum...
This specification establishes the requirements for steel fiber reinforced concrete pipe (SFRCP) of internal diameters 12-48 in., to be used in the conveyance of sewage, industrial wastes, and storm water...
This specification is concerned with insulating covers for use on exposed drain and water supply piping under accessible lavatories and sinks. The thermal insulating properties of the insulating covers are...
This standard covers the use of non-metallic plaster bases with portland cement-based plaster in vertical wall applications and provides details of requirements with respect to inspection of the material as...

<< Prev Next >>