Description
The PROCAP I 3-A and II 3-A meet rigorous USDA, FDA and 3-A material and design standards for sanitary food and dairy processing. They can be used for high and low-level detection in bins, silos, tanks, hoppers, chutes, and other vessels used for the storage or manufacture of food or dairy products. They operate by detecting the presence or absence of material in contact with the probe, sensing minute changes (as low as 0.5 pF) in capacitance caused by the difference in the dielectric constant of the material versus the air. They are available with a wide assortment of probes and extensions to meet a variety of processing needs.
Request a Quote
Description
The PROCAP I 3-A and II 3-A meet rigorous USDA, FDA and 3-A material and design standards for sanitary food and dairy processing. They can be used for high and low-level detection in bins, silos, tanks, hoppers, chutes, and other vessels used for the storage or manufacture of food or dairy products. They operate by detecting the presence or absence of material in contact with the probe, sensing minute changes (as low as 0.5 pF) in capacitance caused by the difference in the dielectric constant of the material versus the air. They are available with a wide assortment of probes and extensions to meet a variety of processing needs.
Request a Quote
Datasheet
Datasheet Summary
Powered by GS/AI

The PROCAP I 3-A and II 3-A are capacitance level sensors designed for sanitary food and dairy applications, featuring a 1" or 2" sanitary 316 SS mounting fitting. They operate with a universal power supply (PROCAP I: 24-240 VAC/VDC; PROCAP II: 115/230 VAC, 50/60 Hz, 2.2 VA) and provide a DPDT relay output rated at 10 A at 250 VAC. The sensors include Pro-Shield technology to compensate for material buildup, a visual LED status indicator, adjustable sensitivity to less than 1 picofarad, and a dual time delay up to 30 seconds. They are rated for ambient temperatures from -40°F to +158°F (-40°C to +70°C) and use Delrin-sleeved probes with a maximum temperature rating of 250°F (121°C). The enclosure is die-cast aluminum with a powder coat finish and FDA-recognized construction, but no regulatory approvals are listed.

Datasheet Summary
Powered by GS/AI

The PROCAP I 3-A and II 3-A are capacitance level sensors designed for sanitary food and dairy applications, featuring a 1" or 2" sanitary 316 SS mounting fitting. They operate with a universal power supply (PROCAP I: 24-240 VAC/VDC; PROCAP II: 115/230 VAC, 50/60 Hz, 2.2 VA) and provide a DPDT relay output rated at 10 A at 250 VAC. The sensors include Pro-Shield technology to compensate for material buildup, a visual LED status indicator, adjustable sensitivity to less than 1 picofarad, and a dual time delay up to 30 seconds. They are rated for ambient temperatures from -40°F to +158°F (-40°C to +70°C) and use Delrin-sleeved probes with a maximum temperature rating of 250°F (121°C). The enclosure is die-cast aluminum with a powder coat finish and FDA-recognized construction, but no regulatory approvals are listed.

Suppliers

Company
Product
Description
Supplier Links
Capacitance Level Sensor Probe for Sanitary Applications - PROCAP I 3-A & II 3-A - BinMaster, Inc.
Lincoln, NE, United States
Capacitance Level Sensor Probe for Sanitary Applications
PROCAP I 3-A & II 3-A
Capacitance Level Sensor Probe for Sanitary Applications PROCAP I 3-A & II 3-A
The PROCAP I 3-A and II 3-A meet rigorous USDA, FDA and 3-A material and design standards for sanitary food and dairy processing. They can be used for high and low-level detection in bins, silos, tanks, hoppers, chutes, and other vessels used for the storage or manufacture of food or dairy products. They operate by detecting the presence or absence of material in contact with the probe, sensing minute changes (as low as 0.5 pF) in capacitance caused by the difference in the dielectric constant of the material versus the air. They are available with a wide assortment of probes and extensions to meet a variety of processing needs.

The PROCAP I 3-A and II 3-A meet rigorous USDA, FDA and 3-A material and design standards for sanitary food and dairy processing. They can be used for high and low-level detection in bins, silos, tanks, hoppers, chutes, and other vessels used for the storage or manufacture of food or dairy products. They operate by detecting the presence or absence of material in contact with the probe, sensing minute changes (as low as 0.5 pF) in capacitance caused by the difference in the dielectric constant of the material versus the air. They are available with a wide assortment of probes and extensions to meet a variety of processing needs.

Supplier's Site Datasheet

Technical Specifications

  BinMaster, Inc.
Product Category Level Sensors
Product Number PROCAP I 3-A & II 3-A
Product Name Capacitance Level Sensor Probe for Sanitary Applications
Device Classification Sensor System
Number of Switch Points Range 1 (#)
Media Type Liquid; Dry material (Bulk solids and powders)
Level Measurement Type Single Point or Multi-Point Level
Unlock Full Specs
to access all available technical data

Similar Products

Level Control Diaphragm Switch for Hazardous Locations - BM65 - BinMaster, Inc.
Specs
Device Classification Sensor System
Number of Switch Points Range 1 (#)
Media Type Dry material (Bulk solids and powders)
View Details
Continuous Level Sensor, 3DLevelScanner - 3DLS S / M / MV - BinMaster, Inc.
Specs
Device Classification Sensor System
Measuring Range ? to 2400 inch (? to 60960 mm)
Media Type Dry material (Bulk solids and powders)
View Details
Fail-Safe Rotary Level Indicator - BMRX-300 - BinMaster, Inc.
Specs
Device Classification Sensor System
Number of Switch Points Range 1 (#)
Media Type Dry material (Bulk solids and powders)
View Details
Vibrating Probe Level Sensor - VRX61 - BinMaster, Inc.
Specs
Device Classification Sensor Only
Media Type Dry material (Bulk solids and powders)
Level Measurement Type Single Point or Multi-Point Level
View Details