ABB Measurement & Analytics 2-wire, field-mount conductivity transmitter, ATEX/IECEx ACA592

Description
ABB's Endura family of analytical transmitters are designed for the requirements of industrial customers. These 24 V DC transmitters are used in measurement and control applications across a broad range of industries including chemical, pulp & paper, mining and petroleum refining. The ACA592 transmitter is compatible with ABB's full range of conductivity sensors. Automatic temperature sensor recognition for both 2- and 3-wire RTD inputs for common inputs such as Pt100, Pt1000 and 3K Balco is included as standard. Data Transmitter options for all sensor types — 2-electrode sensors for low conductivity measurement — 4-electrode sensors for wide range conductivity applications and slurries — Toroidal conductivity for corrosive and heavy coating applications Through-the-glass programming (TTG) configuration Hazardous area approved — IS/NI and Exd Communications — 4 to 20 mA with HART (FDT/DTM/EDD) Continuous sensor and self-monitoring — Electronics self-check
Request a Quote Datasheet
Description
ABB's Endura family of analytical transmitters are designed for the requirements of industrial customers. These 24 V DC transmitters are used in measurement and control applications across a broad range of industries including chemical, pulp & paper, mining and petroleum refining. The ACA592 transmitter is compatible with ABB's full range of conductivity sensors. Automatic temperature sensor recognition for both 2- and 3-wire RTD inputs for common inputs such as Pt100, Pt1000 and 3K Balco is included as standard. Data Transmitter options for all sensor types — 2-electrode sensors for low conductivity measurement — 4-electrode sensors for wide range conductivity applications and slurries — Toroidal conductivity for corrosive and heavy coating applications Through-the-glass programming (TTG) configuration Hazardous area approved — IS/NI and Exd Communications — 4 to 20 mA with HART (FDT/DTM/EDD) Continuous sensor and self-monitoring — Electronics self-check
Request a Quote Datasheet

Suppliers

Company
Product
Description
Supplier Links
2-wire, field-mount conductivity transmitter, ATEX/IECEx - ACA592 - ABB Measurement & Analytics
Zurich, Switzerland
2-wire, field-mount conductivity transmitter, ATEX/IECEx
ACA592
2-wire, field-mount conductivity transmitter, ATEX/IECEx ACA592
ABB's Endura family of analytical transmitters are designed for the requirements of industrial customers. These 24 V DC transmitters are used in measurement and control applications across a broad range of industries including chemical, pulp & paper, mining and petroleum refining. The ACA592 transmitter is compatible with ABB's full range of conductivity sensors. Automatic temperature sensor recognition for both 2- and 3-wire RTD inputs for common inputs such as Pt100, Pt1000 and 3K Balco is included as standard. Data Transmitter options for all sensor types — 2-electrode sensors for low conductivity measurement — 4-electrode sensors for wide range conductivity applications and slurries — Toroidal conductivity for corrosive and heavy coating applications Through-the-glass programming (TTG) configuration Hazardous area approved — IS/NI and Exd Communications — 4 to 20 mA with HART (FDT/DTM/EDD) Continuous sensor and self-monitoring — Electronics self-check

ABB's Endura family of analytical transmitters are designed for the requirements of industrial customers. These 24 V DC transmitters are used in measurement and control applications across a broad range of industries including chemical, pulp & paper, mining and petroleum refining.

The ACA592 transmitter is compatible with ABB's full range of conductivity sensors. Automatic temperature sensor recognition for both 2- and 3-wire RTD inputs for common inputs such as Pt100, Pt1000 and 3K Balco is included as standard.

Data

  • Transmitter options for all sensor types
    — 2-electrode sensors for low conductivity measurement
    — 4-electrode sensors for wide range conductivity applications and slurries
    — Toroidal conductivity for corrosive and heavy coating applications
  • Through-the-glass programming (TTG) configuration
  • Hazardous area approved
    — IS/NI and Exd
  • Communications
    — 4 to 20 mA with HART (FDT/DTM/EDD)
  • Continuous sensor and self-monitoring
    — Electronics self-check
Supplier's Site Datasheet

Technical Specifications

  ABB Measurement & Analytics
Product Category Conductivity and Resistivity Meters
Product Number ACA592
Product Name 2-wire, field-mount conductivity transmitter, ATEX/IECEx
Water Quality Parameters Measures Conductivity / Dissolved Solids
Form Factor Panel (optional feature); Wall, Pipe
Other Output HART
Features and Functionality Automatic Temperature Compensation; Self-test / Diagnostics
Conductivity Range 0.0 to 2.00E6 µS/cm
Unlock Full Specs
to access all available technical data

Similar Products

Fluoride analyzer - Aztec AFM631 - ABB Measurement & Analytics
ABB Measurement & Analytics
Specs
Water Quality Parameters Measures Conductivity / Dissolved Solids
Form Factor Lab / Benchtop
Communication Network/Bus Compatibility PROFIBUS (optional feature)
View Details
Color analyzer - Aztec AW637 - ABB Measurement & Analytics
ABB Measurement & Analytics
Specs
Water Quality Parameters Measures Conductivity / Dissolved Solids
Form Factor Lab / Benchtop
Communication Network/Bus Compatibility Ethernet; PROFIBUS (optional feature)
View Details
Universal 4-wire, dual-input transmitter - AWT420 - ABB Measurement & Analytics
Specs
Water Quality Parameters Measures Conductivity / Dissolved Solids
Form Factor Panel
Communication Network/Bus Compatibility Ethernet (optional feature); PROFIBUS (optional feature)
View Details
Iron analyzer - Aztec AW633 - ABB Measurement & Analytics
ABB Measurement & Analytics
Specs
Water Quality Parameters Measures Conductivity / Dissolved Solids
Form Factor Lab / Benchtop
Communication Network/Bus Compatibility PROFIBUS (optional feature)
View Details