ASTM International Datasheets for Standards and Technical Documents
Standards and technical documents includes standards, codes, regulation, handbooks, manuals, comprehensive guides and other formal publications. Standards, codes, and regulation establish uniform specifications, procedures or technical criteria.
Standards and Technical Documents: Learn more
| Product Name | Notes |
|---|---|
| 1.1 The test procedures of this practice are applicable to any carbonless paper product that employs a coating of micro-capsules bonded to one side of the paper wherein the active... | |
| 1.1 These criteria cover thermoset plastics based on diglycidyl ethers of bisphenol A (DGEBPA) and appropriate curing agents or catalysts as opposed to thermoplastics based on epoxy structures. 1.2 These... | |
| 1.1 These criteria cover thermoset plastics based on diglycidyl ethers of bisphenol A (DGEBPA) and appropriate curing agents or catalysts as opposed to thermoplastics based on epoxy structures. 1.2 These... | |
| 1.1 These criteria cover thermoset plastics based on diglycidyl ethers of bisphenol A(DGEBPA) and appropriate curing agents or catalysts as opposed to thermoplastics based on epoxy structures. 1.2 These criteria... | |
| 1.1 These test methods cover establishment of procedures for conducting tests to determine the mechanical properties of externally and internally threaded fasteners, washers, and rivets. 1.2 Property requirements and the... | |
| 1.1 These test methods cover establishment of procedures for conducting tests to determine the mechanical properties of externally and internally threaded fasteners, washers, direct tension indicators, and rivets. 1.2 Property... | |
| 1.1 These test methods cover establishment of procedures for conducting tests to determine the mechanical properties of metric externally and internally threaded fasteners, washers, and rivets. 1.2 Property requirements and... | |
| 1.1 These test methods cover procedures for the testing of nails. The test or tests selected, and the requirements for compliance, will be as specified in the applicable product standard. | |
| 1.1 These test methods cover the ability of window assemblies of various types to restrain, delay, or frustrate forced entry. 1.2 For purposes of these test methods, window assemblies are... | |
| 1.1 These test methods cover the ability of window assemblies of various types to restrain, delay, or frustrate forced entry. 1.2 For purposes of these test methods, window assemblies are... | |
| 1.1 These test methods cover the determination of the effect of anticipated stresses and strains that vacuum cleaner hoses will receive in normal use. 1.2 These test methods apply to... | |
| 1.1 These test methods cover the determination of the radiopacity of materials and products utilizing X-ray based techniques, including fluoroscopy, angiography, CT (computed tomography) and DEXA (dual energy X-ray absorptiometry),... | |
| 1.1 These test methods cover the determination of the radiopacity of materials and products utilizing X-ray based techniques, including fluoroscopy, angiography, CT (computed tomography) and DEXA, also known as DXA,... | |
| 1.1 These test methods cover the determination of the radiopacity of materials and products utilizing X-ray based techniques, including fluoroscopy, angiography, CT (computed tomography), and DEXA (dual energy X-ray absorptiometry),... | |
| 1.1 These test methods cover the determination, by radiography, of the radiopacity of plastic in the form of film, sheet, rod, tube, and moldings. The results of these measurements are... | |
| 1.1 These test methods cover the nondestructive measurement of bulk resistivity of silicon and certain gallium-arsenide slices and of the sheet resistance of thin films of silicon or gallium-arsenide fabricated... | |
| 1.1 These test methods determine the ability of window assemblies of various types to restrain, delay, or frustrate forced entry. | |
| 1.1 These test methods determine the ability of window assemblies of various types to restrain, delay, or frustrate forced entry. 1.2 For purposes of these test methods, window assemblies are... | |
| 1.1 These test methods establish procedures for conducting tests to determine the mechanical properties of externally and internally threaded fasteners, washers, and rivets. 1.2 Property requirements and the applicable tests... | |
| 1.1 These test methods establish procedures for conducting tests to determine the mechanical properties of metric externally and internally threaded fasteners, washers, and rivets. 1.2 Property requirements and the applicable... | |
| 1.1 This classification provides guidance to engineers and users in the selection of practical vinyl chloride plastics for medical applications and further provides a method for specifying these materials by... | |
| 1.1 This consumer safety specification covers non-powder guns, commonly referred to as BB guns, air guns, and pellet guns, which propel a projectile by means of energy released by compressed... | |
| 1.1 This consumer safety specification covers projectiles and propellants manufactured for use with non-powder guns intended for target shooting, educational, and recreational purposes and is to be used in conjunction... | |
| 1.1 This guide covers the evaluation of thermoplastic polyurethanes in both solid and solution form for biomedical applications. The polymers have been reacted to completion and require no further chemical... | |
| 1.1 This guide describes design and selection considerations and installation procedures for the rehabilitation of sanitary and storm sewers by the insertion of solid wall or profile wall or corrugated... | |
| 1.1 This guide is intended for use in the selection, design, and installation of thermoplastic water pressure piping systems for use outside buildings. For specific projects, a thorough review of... | |
| 1.1 This guide is intended for use in the selection, design, and installation of thermoplastic water systems for use outside buildings. For specific projects, a thorough review of this guide... | |
| 1.1 This guide is intended for use in the selection, design, and installation of thermoplastic water-pressure piping systems. For specific projects, a thorough review of this guide is recommended for... | |
| 1.1 This performance specification establishes performance requirements for the short-term utilization of a single-use, balloon-retention catheter, French sizes 12 through 26 inclusive, used by the medical professions for providing a... | |
| 1.1 This practice covers a method for the visual evaluation of the image quality formed by a carbonless copy paper in a business form when imaged with an electric or... | |
| 1.1 This practice covers a method of testing by which the user can prepare a test for dry electrostatic toners used in copiers, which has significance to their specific copying... | |
| 1.1 This practice covers a procedure for determining the compatibility of one-time carbon paper with carbonless copy papers, interleaved into the same manifold set by forced aging. 1.2 This standard... | |
| 1.1 This practice covers a procedure for determining the compatibility of one-time carbon paper with carbonless copy papers, interleaved into the same manifold set by forced aging. This standard does... | |
| 1.1 This practice covers a procedure for evaluating the quality of molded poly(vinyl chloride) (PVC) plastic pipe fittings after exposure to heat. 1.2 Units-The values stated in either inch-pound or... | |
| 1.1 This practice covers a standardized procedure using an electric typewriter to determine the image quality of one-time carbon paper for use in carbon-interleaved business forms. 1.2 The values stated... | |
| 1.1 This practice covers a standardized procedure using an electric typewriter to determine the image quality of one-time carbon paper for use in carbon-interleaved business forms. 1.2 This standard does... | |
| 1.1 This practice covers conditions for nondestructive visual inspection of the surface finish of spooled aluminum and gold wire used for making internal semiconductor device connections and hybrid microelectronic connections. | |
| 1.1 This practice covers general and basic procedures related to the proper installation of thermoplastic, flexible, pressure piping, 36 in. nominal size and smaller, for underground irrigation systems. Because there... | |
| 1.1 This practice covers methods for extraction of medical plastics in liquids that simulate body fluids in their action on the plastics. This practice identifies two methods of extraction: one... | |
| 1.1 This practice covers methods of extraction of medical plastics and may be applicable to other materials. This practice identifies a method for obtaining "extract liquid" for use in determining... | |
| 1.1 This practice covers methods of extraction of medical plastics and may be applicable to other materials. This practice identifies a method for obtaining “extract liquid” for use in determining... | |
| 1.1 This practice covers procedures for adjusting the size ranges of an airborne discrete particle counter (DPC) to match size/concentration data from a reference DPC that has been calibrated for... | |
| 1.1 This practice covers procedures for calibrating and determining performance of an optical liquid-borne particle counter (LPC) which uses an optical system based upon light extinction measurement. This practice is... | |
| 1.1 This practice covers procedures for determination of particle concentration and particle size distribution in batch samples from filter influent and effluent liquid streams. Challenge materials may be suspensions of... | |
| 1.1 This practice covers procedures for determining operating regions that are safe from metallization burnout induced by current pulses of less than 1-s duration. Note 1-In this practice, "metallization" refers... | |
| 1.1 This practice covers procedures for determining operating regions that are safe from metallization burnout induced by current pulses of less than 1-s duration. Note 1-In this practice, “metallization” refers... | |
| 1.1 This practice covers requirements for the evaluation and specification of implantable shunts as related to resistance to flow, direction of flow, materials, radiopacity, mechanical properties, finish, sterility, and labeling... | |
| 1.1 This practice covers the care and use of intraoral mouth protectors as protective equipment for sports. Mouth protectors includes what are commonly termed mouth guards. 1.2 Mouth protectors, as... | |
| 1.1 This practice covers the care and use of intraoral mouth protectors as protective equipment for sports. 1.2 Mouth protectors, as described herein, refer to either Type I, Type II,... | |
| 1.1 This practice covers the care and use of intraoral mouthguards as protective equipment for sports. 1.2 Mouthguards, as described herein, refer to either Type I, Type II, or Type... | |
| 1.1 This practice covers the determination of toner usage, efficiency of toner deposition on an imaged copy, and dusting in those nonheat fixing copiers utilizing a single-component toner. 1.2 This... | |
| 1.1 This practice covers the determination of toner usage, efficiency of toner deposition on an imaged copy, and dusting in those nonheat fixing copiers utilizing a single-component toner. This standard... | |
| 1.1 This practice covers the instructions and precautions to be observed to ensure satisfactory performance of seams in sheet resilient flooring sealed with liquid seam sealers. 1.2 This standard does... | |
| 1.1 This practice covers the instructions and precautions to be observed to ensure satisfactory performance of seams in sheet resilient flooring sealed with liquid seam sealers. 1.2 This standard does... | |
| 1.1 This practice covers the instructions and precautions to be observed to ensure satisfactory performance of seams in sheet resilient flooring sealed with liquid seam sealers. This standard does not... | |
| 1.1 This practice covers the procedure for radiographic testing of cast metallic surgical implants and related weldments. 1.2 The values stated in inch-pound units are to be regarded as standard. | |
| 1.1 This practice covers the procedure for radiographic testing of cast metallic surgical implants and related weldments. 1.2 Units-The values stated in either SI units or inch-pound units are to... | |
| 1.1 This practice covers the procedure for radiographic testing of cast metallic surgical implants and related weldments. 1.2 The values stated in inch-pound units are to be regarded as standard. | |
| 1.1 This practice covers the procedure for radiographic testing of cast metallic surgical implants and related weldments. 1.2 This standard does not purport to address all of the safety concerns,... | |
| 1.1 This practice covers the procedure for radiographic testing of cast metallic surgical implants and related weldments. 1.2 This standard does not purport to address all of the safety problems,... | |
| 1.1 This practice covers the ranking of slip resistance of footwear sole, heel, or related materials on various walkway surfaces. 1.2 This standard does not purport to address all of... | |
| 1.1 This practice covers two tests comparing the amount of flake of film typewriter ribbons. 1.2 A short test is recommended for partially used ribbons where flake is suspected. 1.3... | |
| 1.1 This practice creates a system of categories that classify water bodies relating to the control of spills of oil and other substances that float on or into a body... | |
| 1.1 This practice describes a procedure for accelerating the crystalline phase transformation of polybutylene from the metastable Form II to the stable Form I by application of hydrostatic pressure in... | |
| 1.1 This practice describes a procedure for the determination of the temperature history of above-ground plastic gas pressure pipe encased in a metallic casing. Such temperature changes may be due... | |
| 1.1 This practice describes design and selection considerations and installation procedures for the construction of new sanitary and storm sewers by the insertion of polyethylene pipe through existing pipe and... | |
| 1.1 This practice is intended as a guide for fluorescent penetrant inspection of metallic surgical implants. 1.2 This standard does not purport to address all of the safety concerns, if... | |
| 1.1 This practice is intended as a guide for fluorescent penetrant inspection of metallic surgical implants. 1.2 This standard does not purport to address all of the safety concerns, if... | |
| 1.1 This practice is intended as a guide for fluorescent penetrant inspection of metallic surgical implants. 1.2 This standard does not purport to address all of the safety problems, if... | |
| 1.1 This practice is intended as a standard for fluorescent penetrant inspection of metallic surgical implants. 1.2 This standard does not purport to address all of the safety concerns, if... | |
| 1.1 This practice lists commonly used types of branch connections for carbon steel, chromium-molybdenum steel pipe and copper-nickel alloy tubing. Branch to run size applications are given in Tables 1,... | |
| 1.1 This practice provides a procedure for comparing the sizes of nonspherical particles in a test sample determined with different types of automatic particle counters, which operate on different measuring... | |
| 1.1 This practice provides guidance in the selection of types and thicknesses of thermal insulation materials for piping, machinery, and equipment for nonnuclear shipboard applications. Methods and materials for installation,... | |
| 1.1 This specification covers aluminum-1% magnesium alloy wire for internal connections in semiconductor devices and is limited to wires of diameter up to and including 0.002 in. (0.051 mm). For... | |
| 1.1 This specification covers coextruded acrylonitrile-butadi ene-styrene (ABS) plastic drain, waste, and vent pipe made to Schedule 40 iron pipe sizes (IPS) and produced by the coextrusion process with concentric... | |
| 1.1 This specification covers detail requirements for residential chain link fence gates, gate posts, and accessories. | |
| 1.1 This specification covers factory-made poly(vinylidene chloride) (PVDC) plastic-lined ferrous metal pipe and fittings primarily intended for conveying corrosive liquids and gases. Requirements for materials, workmanship, dimensions, construction, working pressure... | |
| 1.1 This specification covers leather protector gloves and leather protector mittens to be worn over electrical workers' rubber insulating gloves and rubber insulating mittens. 1.2 It is intended that the... | |
| 1.1 This specification covers poly(vinyl chloride)-coated steel chain-link fabric, coated before weaving. Poly(vinyl chloride) hereinafter will be designated PVC. 1.2 Fabric produced from three classes of wire coatings are covered... | |
| 1.1 This specification covers polyethylene plastics (as defined in Terminology D883) intended for use in medical device applications involving human tissue contact devices, short term indwellings of 30 days or... | |
| 1.1 This specification covers polyvinyl chloride and other conforming organic polymer-coated steel chain-link fabric, coated before weaving. Polyvinyl chloride and other organic polymer coating hereinafter will be designated as polymer... | |
| 1.1 This specification covers preformed cranioplasty plates that allow alteration for covering skull defects. | |
| 1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining system, and a form of marking for large diameters,... | |
| 1.1 This specification covers requirements and test methods for materials, workmanship, dimensions, perforations, pipe stiffness, elongation, joint separation resistance, quality of extruded polyethylene, brittleness, bond, and marking of corrugated polyethylene... | |
| 1.1 This specification covers requirements for primers for use with poly(vinyl chloride) (PVC) pipe and fittings that are to be joined by PVC solvent cements meeting the requirements of Specification... | |
| 1.1 This specification covers silicone elastomers intended for use as materials of construction for fabrication of medical devices. 1.2 Variations in ingredients, processing, and vulcanization (crosslinking/cure) systems of silicone elastomer... | |
| 1.1 This specification covers standard formats for testable semiconductor lead carrier tape suitable for hybrid applications. 1.2 This standard specifies tape width, configuration, and location of guide perforations ("sprocket holes"),... | |
| 1.1 This specification covers the chemical, mechanical, and metallurgical requirements for four grades of unalloyed titanium used for the manufacture of surgical implants. 1.2 The values stated in inch-pound units... | |
| 1.1 This specification covers the material requirements for high-purity, dense aluminum oxide for load-bearing surgical implant applications. 1.2 This specification does not cover finished parts (for example, femoral heads, acetabular... | |
| 1.1 This specification covers the material requirements for high-purity, dense aluminum oxide for load-bearing surgical implant applications. 1.2 This specification does not cover finished parts (for example, femoral heads, acetabular... | |
| 1.1 This specification covers the material requirements for high-purity, dense aluminum oxide for surgical implant applications. 1.2 The values stated in SI units are to be regarded as the standard. | |
| 1.1 This specification covers the material, dimensions, and construction of 5 and 10-gal (20 and 40-L) tanks purchased to store and dispense lubricating oils. The tanks are industrial safety cans... | |
| 1.1 This specification covers the materials, coating requirements, and inspection of fence accessories for chain-link fence for the following: 1.1.1 Post and line caps, 1.1.2 Rail and brace ends, 1.1.3... | |
| 1.1 This specification covers the minimal requirements for alpine skier goggles and faceshields, to provide a reasonable degree of protection against foreign objects striking or lodging in the eye or... | |
| 1.1 This specification covers the minimum requirements for information that shall be provided by the manufacturer or seller of new amusement rides or devices as a part of the initial... | |
| 1.1 This specification covers the requirements for a wrought cobalt-35 nickel-20 chromium-10 molybdenum alloy plate, sheet, and foil used for the manufacture of surgical implants. 1.2 The values stated in... | |
| 1.1 This specification covers the requirements for stainless steel bolts, hex cap screws, and studs 0.25 to 1.50 in., .inclusive, in nominal diameter in a number of alloys in common... | |
| 1.1 This specification covers the requirements for stainless steel bolts, hex cap screws, and studs 0.25 to 1.50 in., inclusive, in nominal diameter in a number of alloys in common... | |
| 1.1 This specification covers the requirements for stainless steel nuts 0.25 to 1.50 in. in nominal diameter inclusive in a number of alloys in common use and intended for service... | |
| 1.1 This specification covers the requirements for titanium 6 aluminum-4 vanadium ELI (extra low interstial) alloy forgings for surgical implants. 1.2 The values stated in inch-pound units are to be... | |
| 1.1 This specification covers the requirements of forged stainless steel for surgical implants when the material forged conforms to Specification F 138 (UNS S31673), Specification F 1314 (UNS S21910), or... | |
| 1.1 This specification covers thermoset plastics based on diglycidyl ethers of bisphenol A and amino functional curing agents or amine catalysts. 1.2 The epoxy encapsulants covered by this specification are... | |
| 1.1 This specification covers Ultra-High Molecular Weight Polyethylene powder (UHMWPE) and fabricated forms intended for use in surgical implants. 1.2 The requirements of this specification apply to UHMWPE in two... | |
| 1.1 This specification covers ultra-high-molecular -weight polyethylene powder (UHMWPE) intended for use in surgical implants. 1.2 The requirements of this specification apply to UHMWPE in two forms. One is virgin... | |
| 1.1 This specification covers wrought carbon steel sleeve type pipe couplings suitable for joining carbon steel pipes. 1.2 Type I couplings are intended for use on all schedules of pipe... | |
| 1.1 This specification establishes performance requirements for the short-term utilization of a single-use, balloon-retention catheter, French sizes 12 through 26 inclusive, used by the medical professions for providing a means... | |
| 1.1 This specification establishes the requirements for wrought and fabricated shapes made from Copper UNS No. C10100, conforming to the chemical requirements of Specification B 170, Grade 1, and suitable... | |
| 1.1 This specification establishes the requirements for wrought and fabricated shapes made from Copper UNS No. C10100, conforming to the chemical requirements of Specification B170, Grade 1, and suitable for... | |
| 1.1 This specification provides construction details and a replacement procedure for the standard carpet and pad to be used when testing vacuum cleaners. 1.2 The values stated in inch-pound units... | |
| 1.1 This specification provides requirements for primers for use with poly(vinyl chloride) (PVC) pipe and fittings that are to be joined by PVC solvent cements meeting the requirements of Specification... | |
| 1.1 This standard provides a guide for determining performance parameters of full-scale oil spill removal devices in recovering floating oil when tested in controlled environments. 1.2 This guide involves the... | |
| 1.1 This standard provides a guide for determining performance parameters of full-scale oil spill removal devices in recovering floating oil when tested in controlled environments. 1.2 This guide involves the... | |
| 1.1 This test method covers a procedure for evaluating the quality of molded poly(vinyl chloride) (PVC) plastic pipe fittings after exposure to heat. 1.2 The values stated in either inch-pound... | |
| 1.1 This test method covers a procedure for evaluating the quality of molded poly(vinyl chloride) (PVC) plastic pipe fittings after exposure to heat. 1.2 The values stated in either SI... | |
| 1.1 This test method covers a single aperture particle size analysis using an electronic sensing zone apparatus. Dry inks, toners, etc., are covered. Particles as small as 1.4 [mu]m and... | |
| 1.1 This test method covers aperture particle size analysis using an electronic sensing zone apparatus provided with a digital pulse processor. Dry inks, toners, and so forth, are covered. Particles... | |
| 1.1 This test method covers measurement of the diameter of silicon wafers up to 205 mm in diameter. Other semiconductor materials with a circular shape can also be measured. 1.2... | |
| 1.1 This test method covers measurement of the resistivity profile perpendicular to the surface of a silicon wafer of known orientation and type. Note 1--This test method may also be... | |
| 1.1 This test method covers measurement of the slip index of footwear sole, heel, or related materials on dry walkway surfaces in the laboratory and in the field. 1.2 The... | |
| 1.1 This test method covers measurement of the static slip resistance of footwear sole, heel, or related materials on walkway surfaces in the laboratory and in the field. 1.2 The... | |
| 1.1 This test method covers only a laboratory test for determining the relative carpet dirt removal effectiveness of household/commercial vacuum cleaners when tested under specified conditions. 1.2 This test method... | |
| 1.1 This test method covers only a laboratory test for determining the relative carpet dirt removal effectiveness of household/commercial vacuum cleaners when tested under specified conditions. 1.2 This test method... | |
| 1.1 This test method covers the determination of heel attachment strength on women's and misses' shoes through application of a static load to the heel. Shoe heels may be made... | |
| 1.1 This test method covers the determination of particle concentration and size distribution of influent and effluent challenge test materials for filter media using a suitable suspending liquid. Challenge materials... | |
| 1.1 This test method covers the determination of the adhesion strength of films to substrates by pulling wires soldered to the films. 1.2 This test method is intended to measure... | |
| 1.1 This test method covers the determination of the performance characteristics of all lithographic electrostatic masters. 1.2 This standard may involve hazardous materials, operations, and equipment. This standard does not... | |
| 1.1 This test method covers the measurement of MOSFET (Note 1) drain leakage current. Note 1-MOS is an acronym for metal-oxide semiconductor; FET is an acronym for field-effect transistor. 1.2... | |
| 1.1 This test method covers the measurement of MOSFET (see Note 1) linear threshold voltage under very low sweep rate or d-c conditions. It is a d-c conductance method applicable... | |
| 1.1 This test method covers the measurement of the unsaturated sink current of transistor-transisto r logic (TTL) devices under specified conditions. 1.2 This standard does not purport to address all... | |
| 1.1 This test method covers the measurement of the unsaturated sink current of transistor-transisto r logic (TTL) devices under specified conditions. 1.2 Units-The values stated in the International System of... | |
| 1.1 This test method determines the resistance of encapsulating compounds to fluids or greases by measuring changes in weight (Note 0) and volume under defined conditions of time and temperature. | |
| 1.1 This test method determines the resistance of encapsulating compounds to fluids or greases by measuring changes in weight (Note 1) and volume under defined conditions of time and temperature. | |
| 1.1 This test method provides a means of determining the degree to which gasket materials under compressive load adhere to metal surfaces. The test conditions described are indicative of those... | |
| Guide for Selection of Tests for Material Properties of Liquid Thermoset Encapsulating Compounds for Electronic and Microelectronic Encapsulation (Withdrawn 1996) | |
| Guide for Selection of Tests for Material Properties of Transfer Molding Compounds for Electronic and Microelectronic Encapsulation (Withdrawn 1996) | |
| Method for Identification of Metal Particulate Contamination Found in Electronic and Microelectronic Components and Systems Using the Ring Oven Technique, With Spot Tests (Withdrawn 1994) | |
| Method for Measuring Mica Stampings or Substitutes Used in Electron Devices and Lamps | |
| Method for Measuring MOSFET Saturated Threshold Voltage (Withdrawn 1985) | |
| Method for Measuring MOSFET Saturated Threshold Voltage | |
| Method for Particle Single-Point Calibration by the Median Method (Withdrawn 1988) | |
| Method of Concentrating and Measuring Trace Quantities of Copper in High-Purity Water Used in the Electronics Industry (Withdrawn 1988) | |
| Method of Concentrating and Measuring Trace Quantities of Copper in High-Purity Water Used in the Electronics Industry | |
| Method of Test for Corrosive and Adhesive Effects of Gasket Materials on Metal Surfaces (Withdrawn 1981) | |
| Method of Test for Phosphate in Electronic Grade Hydrogen Peroxide Solutions (Withdrawn 1992) | |
| Method of Test for Phosphate in Electronic Grade Hydrogen Peroxide Solutions | |
| Method of Test for Tin in Electronic Grade Hydrogen Peroxide Solutions (Withdrawn 1989) | |
| Method of Test for Tin in Electronic Grade Hydrogen Peroxide Solutions | |
| Methods for Detection and Enumeration of Microbiological Contaminants in Water Used for Processing Electron and Microelectronic Devices (Withdrawn 1991) | |
| Methods for Detection and Enumeration of Microbiological Contaminants in Water Used for Processing Electron and Microelectronic Devices | |
| Practice for Accelerated Aging of Photoresist (Withdrawn 1996) | |
| Practice for Accelerated Aging of Photoresist | |
| Practice for Cleaning Surfaces of Polished Silicon Slices (Withdrawn 1993) | |
| Practice for Determining Relative Bias of Two Particle Counters Using Comparison Procedures (Withdrawn 1990) | |
| Practice for Determining Safe Current Pulse Operating Regions for Metallization on Semiconductor Components (Withdrawn 1995) | |
| Practice for Manual Analysis of Interferometric Data by Least-Squares Fitting to a Plane Reference Surface (Withdrawn 1994) | |
| Practice for Manual Analysis of Interferometric Data by Least-Squares Fitting to a Plane Reference Surface | |
| Practice for Manual Analysis of Interferometric Data by Least-Squares Fitting to a Spherical Reference Surface and for Computer-Aided Analysis of Interferometric Data by Least-Squares Fitting to Bo... | |
| Practice for Measurement of the Coating Transfer Resistance of Mechanical Carbonless CB Paper (Withdrawn 1986) | |
| Practice for Nondestructive Ultrasonic Evaluation of Socket and Butt Joints of Thermoplastic Piping (Withdrawn 1989) | |
| Practice for On-Site Calibration of Liquid-Borne Automatic Particle Counters with Adjustable Individual Size Thresholds (Withdrawn 1987) | |
| Practice for Preparation of Photoresist for Analysis of Inorganic Contaminants (Withdrawn 1996) | |
| Practice for Preparation of Photoresist for Analysis of Inorganic Contaminants | |
| Practice for Preparing Photoplates for Measuring Flatness Deviation (Withdrawn 1996) | |
| Practice for Preparing Photoplates for Measuring Flatness Deviation | |
| Practice for Sampling Ground Meat I Blenders (Withdrawn 1995) | |
| Practice for Use of the High-Speed Printer as a Test Instrument for Carbon Paper (Withdrawn 1988) | |
| Practice for Using the Computer Impact Print-Out Unit as a Test Instrument (Withdrawn 1988) | |
| Specification for Diethyl Oxalate for Use in Fabricating Electron Devices (Withdrawn 1984) | |
| Specification for Electronic Grade Soluble Cellulose Nitrate (Withdrawn 1984) | |
| Specification for Polyethylene Gas Pressure Pipe, Tubing, and Fittings (Withdrawn 1989) | |
| Specification for Primary Amyl Acetate (Mixed Isomers) for Use in Fabricating Electron Devices (Withdrawn 1989) | |
| Specification for Safety Consideration for Household Vacuum Cleaners (Withdrawn 1988) | |
| Specification for Stainless Steel Flexible Wire for Surgical Fixation of Bone (Withdrawn 1993) | |
| Specification for Stainless Steel Flexible Wire for Surgical Fixations for Soft Tissue (Withdrawn 1995) | |
| Specification for Strength Requirements of Metal Posts and Rails for Industrial Chain Link Fence (Withdrawn 1995) | |
| Specification for Wrought Cobalt-Chromium Alloy Flexible Wire for Surgical Fixations for Bone (Withdrawn 1993) | |
| Specification for Wrought Cobalt-Chromium Alloy Flexible Wire for Surgical Fixations for Soft Tissue (Withdrawn 1993) | |
| Standard Consumer Safety Specification for Non-Powder Guns | |
| Standard Guide for Collecting Skimmer Performance Data in Controlled Environments | |
| Standard Method of Testing Full Scale Advancing Spill Removal Devices | |
| Standard Specification for Acrylonitrile-Butadi ene-Styrene (ABS) Plastic Drain, Waste, And Vent Pipe Having A Foam Core | |
| Standard Specification for Acrylonitrile-Butadi ene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core | |
| Standard Terminology of Collated and Cohered Fasteners and Their Application Tools (Withdrawn 2017) | |
| Standard Terminology of Collated and Cohered Fasteners and Their Application Tools | |
| Test Method for Adhesion Strength of Bondable Films to Substrates in Ribbon-Wire Bonds (Withdrawn 1996) | |
| Test Method for Adhesion Strength of Bondable Films to Substrates in Ribbon-Wire Bonds | |
| Test Method for Bulk Density of Germanium Dioxide (Withdrawn 1994) | |
| Test Method for Bulk Density of Germanium Dioxide | |
| Test Method for Distortion of Optical Lenses Used in Photomask Fabrication (Withdrawn 1996) | |
| Test Method for Distortion of Optical Lenses Used in Photomask Fabrication | |
| Test Method for Face Flatness by Optical Non-Contact Technique (Withdrawn 1994) | |
| Test Method for Face Flatness by Optical Non-Contact Technique | |
| Test Method for Lasting Threshold and Slope Efficiency of Neodymium-Doped Laser Rods (Withdrawn 1994) | |
| Test Method for Lasting Threshold and Slope Efficiency of Neodymium-Doped Laser Rods | |
| Test Method for Leak Rates Versus Y Stresses and M Factors for Gaskets (Withdrawn 1998) | |
| Test Method for Measuring Nonequilibrium Transient Photocurrents in P-N Junctions (Withdrawn 1995) | |
| Test Method for Measuring Small-Signal Comon Emitter Current Gain of Transistors at High Frequencies (Withdrawn 1995) | |
| Test Method for Photoresist Cleanness--Filterabi lity (Withdrawn 1996) | |
| Test Method for Wavefront Distortion of Nominally Plane Optical Elements Due to Refractive Index Inhomogeneity (Withdrawn 1994) | |
| Test Method of Measuring Specific Resistivity of Electronic Grade Solvents (Withdrawn 1998) | |
| Test Methods for Testing Photoresists Used in Microelectronic Fabrication (Withdrawn 1996) | |
| These test methods cover establishment of procedures for conducting tests to determine the mechanical properties of externally and internally threaded fasteners, washers, direct tension indicators, and rivets. These test methods... | |
| These test methods establishes the standard procedures for conducting tests to determine the mechanical properties of externally and internally threaded fasteners, washers and direct tension indicators, and rivets. For externally... | |
| This practice establishes the standard procedures for ranking the measured slip resistance data of footwear sole, heel, and other related materials on various walkway surfaces. | |
| This practice lists commonly used types of branch connections for carbon steel, chromium-molybdenum steel pipe and copper-nickel alloy tubing. The branch to run size applications are presented in details. The... | |
| This practice provides the design and dimensional details required for the proper selection of the type of, and correct installation procedures for, thermal insulation materials suitable for use on piping,... | |
| This specification covers alpha plus beta titanium alloy forgings for use in surgical implants such as orthopaedic medical devices. The products should be forged by hammering, pressing, extruding, or upsetting... | |
| This specification covers coextruded acrylonitrile-butadi ene-styrene (ABS) plastic drain, waste, and vent pipes made to Schedule 40 iron pipe sizes (IPS) with concentric inner and outer solid ABS layers and... | |
| This specification covers leather protectors for rubber insulating gloves and mittens. Leather protectors shall provide mechanical protection only for the rubber insulating gloves and mittens. Leather material shall be grain... | |
| This specification covers polyvinyl chloride and other conforming organic polymer-coated steel chain-link fabric, coated before weaving. Fabric produced from three classes of wire coatings are covered as follows: Class I... | |
| This specification covers preformed cranioplasty plates that allow alteration of dimensions to fit a particular skull defect. Cranioplasty plates shall be manufactured from unalloyed titanium, wrought cobalt-20chromium-15 tungsten-10nickel alloy, or... | |
| This specification covers requirements and test methods for materials, workmanship, dimensions, perforations, pipe stiffness, elongation, joint separation resistance, quality of extruded polyethylene, brittleness, bond, and marking of corrugated polyethylene (PE)... | |
| This specification covers requirements and test methods for poly(vinyl chloride) (PVC) large-diameter plastic gravity sewer pipe and fittings. Pipe requirements include workmanship, pipe dimensions, flattening resistance, impact resistance, pipe stiffness,... | |
| This specification covers requirements for primers for use with poly(vinyl chloride) (PVC) pipe and fittings that are to be joined by PVC solvent cements. The primer shall be an organic... | |
| This specification covers the attachment, finish, and dimensional requirements for residential chain link fence gates, including frames, posts, fabric, and hardware and accessories associated with them. | |
| This specification covers the chemical, mechanical, and metallurgical requirements for four grades of unalloyed titanium strips, sheets, plates, bars, billets, forgings, and wires used for the manufacture of surgical implants. | |
| This specification covers the material requirements for high-purity, dense aluminum oxide for load bearing surgical implant applications. It mainly addresses qualification of the material as delivered to the parts manufacturer,... | |
| This specification covers the material, design, optical, and strength requirements, and associated test procedures for goggles and faceshields used by alpine skiers, to provide a reasonable degree of protection against... | |
| This specification covers the material, dimensions, and construction of 5 and 10-gal (20 and 40-L) tanks purchased to store and dispense lubricating oils. The tanks are industrial safety cans mounted... | |
| This specification covers the materials, coating requirements, and inspection of the following fence accessories that are used for chain-link fences: post and line caps; rail and brace ends; top rail... | |
| This specification covers the minimum requirements for information that shall be provided by the manufacturer or seller of new amusement rides or devices as a part of the initial sale... | |
| This specification covers the properties for polyethylene plastics for use in medical device applications involving human tissue contact devices, short term indwellings, and fluid transfer devices. Biocompatibility tests must be... | |
| This specification covers the requirements for stainless steel forgings for surgical implants. Materials for forgings shall be bars or wire and shall be forged by hammering, pressing, rolling, extruding, or... | |
| This specification covers the requirements for stainless steel nuts in specified size, inclusive, in nominal diameter in a number of alloys in common use and intended for service applications requiring... | |
| This specification covers the requirements for wrought cobalt-35nickel-20ch romium-10molybdenum alloy for use in the manufacture of surgical implants. The alloy shall be manufactured into plates, sheets, and foils in the... | |
| This specification covers thermoset plastics based on diglycidyl ethers of bisphenol A and amino functional curing agents or amine catalysts for implantable epoxy electronic encapsulants. Encapsulants shall be classified depending... | |
| This specification covers ultra-high-molecular -weight polyethylene (UHMWPE) powder and fabricated forms for use in surgical implants. UHMWPE powder shall be of virgin polymer manufactured from a homopolymer of ethylene, while... | |
| This specification covers wrought carbon steel sleeve type pipe couplings suitable for joining carbon steel pipes. Couplings are furnished in two types as follows: Type I couplings are intended for... | |
| This specification establishes the requirements for wrought forms and fabricated shapes of oxygen-free copper with UNS No. C10100 suitable for use in electron devices. Specimens shall be appropriately sampled and... | |
| This specification provides the construction details, replacement procedures, and selection criteria for the standard test carpets and pads used when testing vacuum cleaners. The carpet types, which shall be constructed... | |
| This standard was transferred to SEMI (www.semi.org) May 2003 1.1 These test methods cover the nondestructive measurement of bulk resistivity of silicon and certain gallium-arsenide slices and of the sheet... | |
| This standard was transferred to SEMI (www.semi.org) May 2003 1.1 This practice covers the surface preparation of silicon samples prior to measurement of resistivity variations by the spreading resistance technique. | |
| This standard was transferred to SEMI (www.semi.org) May 2003 1.1 This test method covers a noncontacting, nondestructive procedure to determine the warp and total thickness variation (TTV) of clean, dry... | |
| This standard was transferred to SEMI (www.semi.org) May 2003 1.1 This test method covers measurement of the resistivity profile perpendicular to the surface of a silicon wafer of known orientation... | |
| This standard was transferred to SEMI (www.semi.org) May 2003 1.1 This test method covers techniques for determination of the length of the flatted portion of a wafer periphery. 1.2 This... |
| << Prev | Next >> |