Det-Tronics Gas Panel GP16

Description
Designed to meet life-safety requirements as a combustible or toxic gas controller, the GP16 Gas Panel is a pre-configured Eagle Quantum Premier® (EQP) System that incorporates combustible and/or toxic gas detectors. GP16 offers three communication options: 1) Local Operating Network (LON) communication, 2) 4-20 mA and LON combined, 3) 4-20 mA only. The touch screen and alarm sounder on the front of the panel offer fast display and annunciation of system conditions. Flexible The Model GP16 is a good fit for applications that require some combination of up to 16 toxic/combustible gas detectors and/or 4-20 mA devices. System options accommodate multiple types of field devices and communication protocols. Functional The Human-Machine Interface (HMI) touch screen provides an interactive window for alarm and fault logs, configurable tag names, and real-time gas readings. The system is pre-wired, pre-configured, and device ready -- built to your specifications. Even the system high- and low-alarm limits are preset. Reliable Built-in reliability optimizes availability and reduces maintenance costs. The Det-Tronics EQP System components and field devices carry 3rd-party approvals to industry life-safety standards around the world.
Description
Designed to meet life-safety requirements as a combustible or toxic gas controller, the GP16 Gas Panel is a pre-configured Eagle Quantum Premier® (EQP) System that incorporates combustible and/or toxic gas detectors. GP16 offers three communication options: 1) Local Operating Network (LON) communication, 2) 4-20 mA and LON combined, 3) 4-20 mA only. The touch screen and alarm sounder on the front of the panel offer fast display and annunciation of system conditions. Flexible The Model GP16 is a good fit for applications that require some combination of up to 16 toxic/combustible gas detectors and/or 4-20 mA devices. System options accommodate multiple types of field devices and communication protocols. Functional The Human-Machine Interface (HMI) touch screen provides an interactive window for alarm and fault logs, configurable tag names, and real-time gas readings. The system is pre-wired, pre-configured, and device ready -- built to your specifications. Even the system high- and low-alarm limits are preset. Reliable Built-in reliability optimizes availability and reduces maintenance costs. The Det-Tronics EQP System components and field devices carry 3rd-party approvals to industry life-safety standards around the world.

Suppliers

Company
Product
Description
Supplier Links
Minneapolis, MN, USA
Gas Panel
GP16
Gas Panel GP16
Designed to meet life-safety requirements as a combustible or toxic gas controller, the GP16 Gas Panel is a pre-configured Eagle Quantum Premier® (EQP) System that incorporates combustible and/or toxic gas detectors. GP16 offers three communication options: 1) Local Operating Network (LON) communication, 2) 4-20 mA and LON combined, 3) 4-20 mA only. The touch screen and alarm sounder on the front of the panel offer fast display and annunciation of system conditions. Flexible The Model GP16 is a good fit for applications that require some combination of up to 16 toxic/combustible gas detectors and/or 4-20 mA devices. System options accommodate multiple types of field devices and communication protocols. Functional The Human-Machine Interface (HMI) touch screen provides an interactive window for alarm and fault logs, configurable tag names, and real-time gas readings. The system is pre-wired, pre-configured, and device ready -- built to your specifications. Even the system high- and low-alarm limits are preset. Reliable Built-in reliability optimizes availability and reduces maintenance costs. The Det-Tronics EQP System components and field devices carry 3rd-party approvals to industry life-safety standards around the world.

Designed to meet life-safety requirements as a combustible or toxic gas controller, the GP16 Gas Panel is a pre-configured Eagle Quantum Premier® (EQP) System that incorporates combustible and/or toxic gas detectors.
GP16 offers three communication options: 1) Local Operating Network (LON) communication, 2) 4-20 mA and LON combined, 3) 4-20 mA only.
The touch screen and alarm sounder on the front of the panel offer fast display and annunciation of system conditions.

Flexible

  • The Model GP16 is a good fit for applications that require some combination of up to 16 toxic/combustible gas detectors and/or 4-20 mA devices.
  • System options accommodate multiple types of field devices and communication protocols.

Functional

  • The Human-Machine Interface (HMI) touch screen provides an interactive window for alarm and fault logs, configurable tag names, and real-time gas readings.
  • The system is pre-wired, pre-configured, and device ready -- built to your specifications. Even the system high- and low-alarm limits are preset.

Reliable

  • Built-in reliability optimizes availability and reduces maintenance costs.
  • The Det-Tronics EQP System components and field devices carry 3rd-party approvals to industry life-safety standards around the world.
Supplier's Site

Technical Specifications

  Det-Tronics
Product Category Gas Instruments
Product Number GP16
Product Name Gas Panel
Application Process Gas
Electrical Outputs Current
Display Digital
Features Audible or Visual Alarms; Controller
Unlock Full Specs
to access all available technical data

Similar Products

Data Logger Software for XP-3300 Gas Detectors -  - DOD Technologies Inc.
Specs
Features Intrinsically Safe
Instrument Type Detector
Mounting Type Portable
View Details
4-Point Centralized Gas Detection System - CEL4 Series - Acme Engineering Products
Specs
Measurement Type Trace
Application Ambient Air Monitoring
Gas Types Toxic; Combustible; CO2 (optional feature); CO (optional feature); Cl2 (optional feature); Hydrocarbons (optional feature); H2 (optional feature); H2S (optional feature); Methane (CH4) / Natural Gas (optional feature); NO2 (optional feature); O2 (optional feature); SO2 (optional feature)
View Details
Airborne Particle-Counting Hygiene Meter - PCE-RCM 12 - PCE Instruments / PCE Americas Inc.
Specs
Gas Types Toxic; Combustible; CO2; (0 ... 9999 ppm); Water Vapor; (0 ... 100 % r.H.); (Formaldehyde (HCHO))
Display Digital
Instrument Type Detector
View Details
Portable 5% CO2 Safety Detector -  - CO2Meter.com
Specs
Gas Types CO2; (Search Results - Portable 5% CO2 Safety Detector)
Number of Gases Monitored Single
View Details