Thyracont Vacuum Instruments GmbH Smartline™ Vacuum Transducer VSM72

Description
Absolute Pressure 1000 mbar to 5 x 10-9 mbar (=hPa), 750 Torr to 5 x 10-9 Torr The compact VSM72 Pirani/cold cathode combination transducer measures absolute pressure from atmosphere to ultrahigh vacuum. The intelligent, micro processor driven Smartline transducers automatically control the appropriate interaction of both vacuum sensors regarding measurement ranges and switching points to achieve high accuracy. Benefits Combination sensor with wide measuring range Patented pulsed Pirani sensor with extended range allows operation of the cold cathode at lower pressure and increase of lifetime Robust cold cathode sensor, insensitive against inrush of air Logarithmic signal output 0 - 10 V and RS485 interface Replaceable sensor head Excellent ignition behavior Correct pressure readings by means of separate gas type correction factors for Pirani and cold cathode sensors Two independent, dry relay switch points Typical Applications Analysis instruments Coating plants and vapor deposition Mass spectrometry Process engineering Sputtering plants Vacuum furnaces
Description
Absolute Pressure 1000 mbar to 5 x 10-9 mbar (=hPa), 750 Torr to 5 x 10-9 Torr The compact VSM72 Pirani/cold cathode combination transducer measures absolute pressure from atmosphere to ultrahigh vacuum. The intelligent, micro processor driven Smartline transducers automatically control the appropriate interaction of both vacuum sensors regarding measurement ranges and switching points to achieve high accuracy. Benefits Combination sensor with wide measuring range Patented pulsed Pirani sensor with extended range allows operation of the cold cathode at lower pressure and increase of lifetime Robust cold cathode sensor, insensitive against inrush of air Logarithmic signal output 0 - 10 V and RS485 interface Replaceable sensor head Excellent ignition behavior Correct pressure readings by means of separate gas type correction factors for Pirani and cold cathode sensors Two independent, dry relay switch points Typical Applications Analysis instruments Coating plants and vapor deposition Mass spectrometry Process engineering Sputtering plants Vacuum furnaces

Suppliers

Company
Product
Description
Supplier Links
Smartline™ Vacuum Transducer - VSM72 - Thyracont Vacuum Instruments GmbH
Passau, Germany
Smartline™ Vacuum Transducer
VSM72
Smartline™ Vacuum Transducer VSM72
Absolute Pressure 1000 mbar to 5 x 10-9 mbar (=hPa), 750 Torr to 5 x 10-9 Torr The compact VSM72 Pirani/cold cathode combination transducer measures absolute pressure from atmosphere to ultrahigh vacuum. The intelligent, micro processor driven Smartline transducers automatically control the appropriate interaction of both vacuum sensors regarding measurement ranges and switching points to achieve high accuracy. Benefits Combination sensor with wide measuring range Patented pulsed Pirani sensor with extended range allows operation of the cold cathode at lower pressure and increase of lifetime Robust cold cathode sensor, insensitive against inrush of air Logarithmic signal output 0 - 10 V and RS485 interface Replaceable sensor head Excellent ignition behavior Correct pressure readings by means of separate gas type correction factors for Pirani and cold cathode sensors Two independent, dry relay switch points Typical Applications Analysis instruments Coating plants and vapor deposition Mass spectrometry Process engineering Sputtering plants Vacuum furnaces

Absolute Pressure 1000 mbar to 5 x 10-9 mbar (=hPa), 750 Torr to 5 x 10-9 Torr

The compact VSM72 Pirani/cold cathode combination transducer measures absolute pressure from atmosphere to ultrahigh vacuum.
The intelligent, micro processor driven Smartline transducers automatically control the appropriate interaction of both vacuum sensors regarding measurement ranges and switching points to achieve high accuracy.

Benefits

  • Combination sensor with wide measuring range
  • Patented pulsed Pirani sensor with extended range allows operation of the cold cathode at lower pressure and increase of lifetime
  • Robust cold cathode sensor, insensitive against inrush of air
  • Logarithmic signal output 0 - 10 V and RS485 interface
  • Replaceable sensor head
  • Excellent ignition behavior
  • Correct pressure readings by means of separate gas type correction factors for Pirani and cold cathode sensors
  • Two independent, dry relay switch points

Typical Applications

  • Analysis instruments
  • Coating plants and vapor deposition
  • Mass spectrometry
  • Process engineering
  • Sputtering plants
  • Vacuum furnaces
Supplier's Site

Technical Specifications

  Thyracont Vacuum Instruments GmbH
Product Category Vacuum Sensors
Product Number VSM72
Product Name Smartline™ Vacuum Transducer
Device Category Sensor (optional feature)
Unlock Full Specs
to access all available technical data

Similar Products

Ceracore UTC30 Pressure Transducer - UTC30 - Endress + Hauser – Sensors & Components
Endress + Hauser – Sensors & Components
Specs
Device Category Sensor or Transducer; Switch (optional feature)
Sensor Technology Capacitive Ceramic
Signal Output Analog Voltage; Switch; Digital SPI or UART, Temperature
View Details
Pneumatic Pressure Sensors - 1754654 - RS Components, Ltd.
Specs
Device Category Sensor
Vacuum Range 0.0 torr (29.92 in Hg vac)
Pressure Measurement Differential; Gauge; Vacuum; Relative Pressure, Vacuum, Differential
View Details
Pressure sensors & Load sensors - Pressure measuring cells - PEWA700 - Angst+Pfister Sensors and Power
Specs
Device Category Sensor
Signal Output Analog Voltage; Analogue, Digital
Features Temperature Compensated
View Details
Pressure sensor - SDE3-V1Z-B-HQ4-2N-M8 - Festo Corporation
Specs
Device Category Sensor
Sensor Technology Piezoelectric
Display Type Digital Numerical Display; Illuminated LCD
View Details
2 suppliers