RainWise, Inc. Wet/Dry Bulb Temperature Sensor T/WD

Description
Wet Bulb / Dry Bulb Temperature Sensor The RainWise Wet Bulb/Dry Bulb Thermometer consists of two calibrated temperature sensors in a fan aspirated housing. Both of the sensors are exposed to the aspirated air. One of them is encased in a fabric wick. This wick is wetted from a small sump. This sump is filled from a reservoir prior to each reading by a remotely located pump. Product Features This assembly is mounted in a housing that utilizes the standard RainWise Monopod mount. For applications not involving the Monopod , a NEMA 4X enclosure is provided adapted to the mount. The outputs from the temperature sensors, when interfaced with a RainWise logger will provide relative humidity as well as wet and dry bulb temperatures. In operation, when a reading is taken, the fan is first turned on for several minutes. At the same time the pump is turned on for 10 seconds to fill the sump and finally the microprocessor monitors the wet bulb readings and determines when a minimum is reached. 5 Year Guarantee
Datasheet
Description
Wet Bulb / Dry Bulb Temperature Sensor The RainWise Wet Bulb/Dry Bulb Thermometer consists of two calibrated temperature sensors in a fan aspirated housing. Both of the sensors are exposed to the aspirated air. One of them is encased in a fabric wick. This wick is wetted from a small sump. This sump is filled from a reservoir prior to each reading by a remotely located pump. Product Features This assembly is mounted in a housing that utilizes the standard RainWise Monopod mount. For applications not involving the Monopod , a NEMA 4X enclosure is provided adapted to the mount. The outputs from the temperature sensors, when interfaced with a RainWise logger will provide relative humidity as well as wet and dry bulb temperatures. In operation, when a reading is taken, the fan is first turned on for several minutes. At the same time the pump is turned on for 10 seconds to fill the sump and finally the microprocessor monitors the wet bulb readings and determines when a minimum is reached. 5 Year Guarantee
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Wet/Dry Bulb Temperature Sensor - T/WD - RainWise, Inc.
Trenton, ME, USA
Wet/Dry Bulb Temperature Sensor
T/WD
Wet/Dry Bulb Temperature Sensor T/WD
Wet Bulb / Dry Bulb Temperature Sensor The RainWise Wet Bulb/Dry Bulb Thermometer consists of two calibrated temperature sensors in a fan aspirated housing. Both of the sensors are exposed to the aspirated air. One of them is encased in a fabric wick. This wick is wetted from a small sump. This sump is filled from a reservoir prior to each reading by a remotely located pump. Product Features This assembly is mounted in a housing that utilizes the standard RainWise Monopod mount. For applications not involving the Monopod , a NEMA 4X enclosure is provided adapted to the mount. The outputs from the temperature sensors, when interfaced with a RainWise logger will provide relative humidity as well as wet and dry bulb temperatures. In operation, when a reading is taken, the fan is first turned on for several minutes. At the same time the pump is turned on for 10 seconds to fill the sump and finally the microprocessor monitors the wet bulb readings and determines when a minimum is reached. 5 Year Guarantee

Wet Bulb / Dry Bulb Temperature Sensor

The RainWise Wet Bulb/Dry Bulb Thermometer consists of two calibrated temperature sensors in a fan aspirated housing. Both of the sensors are exposed to the aspirated air. One of them is encased in a fabric wick. This wick is wetted from a small sump. This sump is filled from a reservoir prior to each reading by a remotely located pump.

Product Features

This assembly is mounted in a housing that utilizes the standard RainWise Monopod mount. For applications not involving the Monopod , a NEMA 4X enclosure is provided adapted to the mount.
The outputs from the temperature sensors, when interfaced with a RainWise logger will provide relative humidity as well as wet and dry bulb temperatures.
In operation, when a reading is taken, the fan is first turned on for several minutes. At the same time the pump is turned on for 10 seconds to fill the sump and finally the microprocessor monitors the wet bulb readings and determines when a minimum is reached.
5 Year Guarantee

Supplier's Site Datasheet

Technical Specifications

  RainWise, Inc.
Product Category Hygrometers and Humidity Measurement Instruments
Product Number T/WD
Product Name Wet/Dry Bulb Temperature Sensor
Variables Measured Temperature
Unlock Full Specs
to access all available technical data

Similar Products

Electronic Hygrotherm ETF 012 - 01230.0-00 - STEGO
Specs
Variables Measured Relative Humidity; Temperature
Form Factor Instrument
Relative Humidity Range 50 to 90 %
View Details
Datalogging Humidity Detector - PCE-HT110 - PCE Instruments / PCE Americas Inc.
PCE Instruments / PCE Americas Inc.
Specs
Features Battery Powered
Variables Measured Relative Humidity; Temperature
Form Factor Meter
View Details
Dewpoint Transmitter - AcuDew - Shaw Moisture Meters
Shaw Moisture Meters
Specs
Variables Measured DewPoint
Form Factor Meter
Dew Point Range -184 to 68 F (-120 to 20 C)
View Details