The Model 7011 deluge activation CO monitor was developed to activate the deluge type fire suppression systems. In most instances CO is liberated long before flames are present. This provides precious minutes of fire suppression water to be applied before a fire may reach an out of control situation. This unit can be installed as a stand alone fire (CO) detection to operate the deluge valve. If an operator is operating a Pyott Boone Atmospheric Monitoring System, personnel will be alerted once the Model 7011 CO Monitor has activated the fire suppression system. Fire fighters can be dispatched almost immediately. The point type heat sensors will probably still be required along with the deluge control panels, by MSHA. AC powered with battery backup LCD Display for setup, calibration and testing Programmable alarm set points and alarm delay Earliest probable fire detection available Provides the best known safety for employees and asset protection Sounder
Description
The Model 7011 deluge activation CO monitor was developed to activate the deluge type fire suppression systems. In most instances CO is liberated long before flames are present. This provides precious minutes of fire suppression water to be applied before a fire may reach an out of control situation. This unit can be installed as a stand alone fire (CO) detection to operate the deluge valve. If an operator is operating a Pyott Boone Atmospheric Monitoring System, personnel will be alerted once the Model 7011 CO Monitor has activated the fire suppression system. Fire fighters can be dispatched almost immediately. The point type heat sensors will probably still be required along with the deluge control panels, by MSHA. AC powered with battery backup LCD Display for setup, calibration and testing Programmable alarm set points and alarm delay Earliest probable fire detection available Provides the best known safety for employees and asset protection Sounder

Suppliers

Company
Product
Description
Supplier Links
Gas Monitoring - Model 7011 - Pyott-Boone Electronics (PBE Group)
North Tazewell, VA, USA
Gas Monitoring
Model 7011
Gas Monitoring Model 7011
The Model 7011 deluge activation CO monitor was developed to activate the deluge type fire suppression systems. In most instances CO is liberated long before flames are present. This provides precious minutes of fire suppression water to be applied before a fire may reach an out of control situation. This unit can be installed as a stand alone fire (CO) detection to operate the deluge valve. If an operator is operating a Pyott Boone Atmospheric Monitoring System, personnel will be alerted once the Model 7011 CO Monitor has activated the fire suppression system. Fire fighters can be dispatched almost immediately. The point type heat sensors will probably still be required along with the deluge control panels, by MSHA. AC powered with battery backup LCD Display for setup, calibration and testing Programmable alarm set points and alarm delay Earliest probable fire detection available Provides the best known safety for employees and asset protection Sounder

The Model 7011 deluge activation CO monitor was developed to activate the deluge type fire suppression systems. In most instances CO is liberated long before flames are present. This provides precious minutes of fire suppression water to be applied before a fire may reach an out of control situation. This unit can be installed as a stand alone fire (CO) detection to operate the deluge valve. If an operator is operating a Pyott Boone Atmospheric Monitoring System, personnel will be alerted once the Model 7011 CO Monitor has activated the fire suppression system. Fire fighters can be dispatched almost immediately. The point type heat sensors will probably still be required along with the deluge control panels, by MSHA.

  • AC powered with battery backup
  • LCD Display for setup, calibration and testing
  • Programmable alarm set points and alarm delay
  • Earliest probable fire detection available
  • Provides the best known safety for employees and asset protection
  • Sounder
Supplier's Site

Technical Specifications

  Pyott-Boone Electronics (PBE Group)
Product Category Gas Instruments
Product Number Model 7011
Product Name Gas Monitoring
Application Confined Space Entry
Unlock Full Specs
to access all available technical data

Similar Products

CO2 Analyzer - PCE-AC 2000 - PCE Instruments / PCE Americas Inc.
PCE Instruments / PCE Americas Inc.
Specs
Measurement Type Trace
Gas Types CO2
Display Digital
View Details
Infrared Vapor Flamability Analyzer - SNR610 - Control Instruments Corp.
Specs
Measurement Type %LEL or %LFL
Application Ambient Air Monitoring; Process Gas
Gas Types Combustible; Hydrocarbons; (0-100% LFL); Methane (CH4) / Natural Gas; (0-100% LFL)
View Details
Zirconia Oxygen Analyzer Converter - ZKMA/ZKMB Series - Fuji Electric Corp. of America
Specs
Application Confined Space Entry
Gas Types O2; (2 to 50vol%); (Zirconium Oxygen)
Display Digital
View Details
G7c Portable Cellular Connected Monitor -  - DOD Technologies Inc.
Specs
Gas Types Combustible
Display Digital
Features Audible or Visual Alarms; Data Logger
View Details