Pyott-Boone Electronics (PBE Group) Gas Monitoring Model 7011

Description
The Model 7011 deluge activation CO monitor was developed to activate the deluge type fire suppression systems. In most instances CO is liberated long before flames are present. This provides precious minutes of fire suppression water to be applied before a fire may reach an out of control situation. This unit can be installed as a stand alone fire (CO) detection to operate the deluge valve. If an operator is operating a Pyott Boone Atmospheric Monitoring System, personnel will be alerted once the Model 7011 CO Monitor has activated the fire suppression system. Fire fighters can be dispatched almost immediately. The point type heat sensors will probably still be required along with the deluge control panels, by MSHA. AC powered with battery backup LCD Display for setup, calibration and testing Programmable alarm set points and alarm delay Earliest probable fire detection available Provides the best known safety for employees and asset protection Sounder
Description
The Model 7011 deluge activation CO monitor was developed to activate the deluge type fire suppression systems. In most instances CO is liberated long before flames are present. This provides precious minutes of fire suppression water to be applied before a fire may reach an out of control situation. This unit can be installed as a stand alone fire (CO) detection to operate the deluge valve. If an operator is operating a Pyott Boone Atmospheric Monitoring System, personnel will be alerted once the Model 7011 CO Monitor has activated the fire suppression system. Fire fighters can be dispatched almost immediately. The point type heat sensors will probably still be required along with the deluge control panels, by MSHA. AC powered with battery backup LCD Display for setup, calibration and testing Programmable alarm set points and alarm delay Earliest probable fire detection available Provides the best known safety for employees and asset protection Sounder

Suppliers

Company
Product
Description
Supplier Links
Gas Monitoring - Model 7011 - Pyott-Boone Electronics (PBE Group)
North Tazewell, VA, USA
Gas Monitoring
Model 7011
Gas Monitoring Model 7011
The Model 7011 deluge activation CO monitor was developed to activate the deluge type fire suppression systems. In most instances CO is liberated long before flames are present. This provides precious minutes of fire suppression water to be applied before a fire may reach an out of control situation. This unit can be installed as a stand alone fire (CO) detection to operate the deluge valve. If an operator is operating a Pyott Boone Atmospheric Monitoring System, personnel will be alerted once the Model 7011 CO Monitor has activated the fire suppression system. Fire fighters can be dispatched almost immediately. The point type heat sensors will probably still be required along with the deluge control panels, by MSHA. AC powered with battery backup LCD Display for setup, calibration and testing Programmable alarm set points and alarm delay Earliest probable fire detection available Provides the best known safety for employees and asset protection Sounder

The Model 7011 deluge activation CO monitor was developed to activate the deluge type fire suppression systems. In most instances CO is liberated long before flames are present. This provides precious minutes of fire suppression water to be applied before a fire may reach an out of control situation. This unit can be installed as a stand alone fire (CO) detection to operate the deluge valve. If an operator is operating a Pyott Boone Atmospheric Monitoring System, personnel will be alerted once the Model 7011 CO Monitor has activated the fire suppression system. Fire fighters can be dispatched almost immediately. The point type heat sensors will probably still be required along with the deluge control panels, by MSHA.

  • AC powered with battery backup
  • LCD Display for setup, calibration and testing
  • Programmable alarm set points and alarm delay
  • Earliest probable fire detection available
  • Provides the best known safety for employees and asset protection
  • Sounder
Supplier's Site

Technical Specifications

  Pyott-Boone Electronics (PBE Group)
Product Category Gas Instruments
Product Number Model 7011
Product Name Gas Monitoring
Application Confined Space Entry
Unlock Full Specs
to access all available technical data

Similar Products

Ammonia (NH3) Combustible Fixed Gas Detector (0-100ppm) -  - CO2Meter.com
Specs
Gas Types Combustible; (Combustible Fixed Gas Detectors - Ammonia (NH3) Combustible Fixed Gas Detector (0-100ppm))
Number of Gases Monitored Single
Operating Temperature -30 to 122 F (-34 to 50 C)
View Details
Flue Gas Oxygen Analyzer - WDG 1210 - LAND
Specs
Measurement Type %Volume
Application Continuous Emissions Monitoring
Gas Types Toxic; O2; (From 0 to 1 %, 0 to 25 %)
View Details
Toxic Gas/Oxygen Transmitter - EC-Gold - Arjay Engineering
Specs
Measurement Type %Volume; Trace
Application Ambient Air Monitoring
Gas Types Toxic; Combustible; NH3; (0-100ppm); CO; (0-500ppm); Cl2; (0-10ppm); Refrigerants; H2S; (0-100ppm); NO2; (0-20ppm); O2; (0-30%)
View Details
4001 Trimix Analyzer Power Cord -  - Analytical Industries Inc.
Analytical Industries Inc.
Specs
Instrument Type Analyzer
View Details