Readings You Can Count On No water supply is completely pure. Every industrial, commercial, or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life. Myron L® Company has two proven ways to measure such impurities. Our DS Meters™ provide fast, accurate, on-the-spot measurements of total dissolved solids (TDS) or conductivity. pDS Meters™ test conductivity or TDS, plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications, some of which are listed above. Unique Field-Tested Design Our unique, durable, field-tested design has evolved over more than 40 years, making Myron L® instruments among the most reliable and popular of their kind in the world. They’re lightweight and compact, yet Myron L®’s DS and pDS Meters are also tough, with rugged, taut-band meter movements. Put our meters to the test. Even after years of rough field service, they’ll surpass your expectations of accuracy, reliability and simplicity.
Request a Quote
Description
Readings You Can Count On No water supply is completely pure. Every industrial, commercial, or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life. Myron L® Company has two proven ways to measure such impurities. Our DS Meters™ provide fast, accurate, on-the-spot measurements of total dissolved solids (TDS) or conductivity. pDS Meters™ test conductivity or TDS, plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications, some of which are listed above. Unique Field-Tested Design Our unique, durable, field-tested design has evolved over more than 40 years, making Myron L® instruments among the most reliable and popular of their kind in the world. They’re lightweight and compact, yet Myron L®’s DS and pDS Meters are also tough, with rugged, taut-band meter movements. Put our meters to the test. Even after years of rough field service, they’ll surpass your expectations of accuracy, reliability and simplicity.
Request a Quote
Datasheet
Datasheet Summary
Powered by GS/AI

The M6/PH is a pDS Meter designed for measuring conductivity, TDS, and pH in field applications. It features a built-in conductivity sensor that does not require replatinizing and a field-replaceable KCl gel-filled pH electrode with a porous liquid junction. The meter has a 2.5-inch taut-band shock-resistant display, automatic temperature compensation to 25°C, and measures conductivity in ranges of 0-50 and 0-5000 ppm or µS, with pH 2-12. Power is supplied by a 9-volt battery with over 2000 tests per year life. The unit is housed in a compact, rugged case measuring 3.4 W × 4.5 D × 4.0 H inches (86 × 114 × 102 mm) and weighs 1 lb. (0.45 kg). Accuracy is ±2% full scale for conductivity and ±0.2 pH units. Calibration is field-adjustable via pH Zero and pH Gain controls, and it uses NIST-traceable standards. The instrument includes a chip- and crack-resistant polyethylene cell cup.

Datasheet Summary
Powered by GS/AI

The M6/PH is a pDS Meter designed for measuring conductivity, TDS, and pH in field applications. It features a built-in conductivity sensor that does not require replatinizing and a field-replaceable KCl gel-filled pH electrode with a porous liquid junction. The meter has a 2.5-inch taut-band shock-resistant display, automatic temperature compensation to 25°C, and measures conductivity in ranges of 0-50 and 0-5000 ppm or µS, with pH 2-12. Power is supplied by a 9-volt battery with over 2000 tests per year life. The unit is housed in a compact, rugged case measuring 3.4 W × 4.5 D × 4.0 H inches (86 × 114 × 102 mm) and weighs 1 lb. (0.45 kg). Accuracy is ±2% full scale for conductivity and ±0.2 pH units. Calibration is field-adjustable via pH Zero and pH Gain controls, and it uses NIST-traceable standards. The instrument includes a chip- and crack-resistant polyethylene cell cup.

Suppliers

Company
Product
Description
Supplier Links
pDS Meter - M6/PH - Myron L Company
Carlsbad, CA, USA
pDS Meter
M6/PH
pDS Meter M6/PH
Readings You Can Count On No water supply is completely pure. Every industrial, commercial, or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life. Myron L® Company has two proven ways to measure such impurities. Our DS Meters™ provide fast, accurate, on-the-spot measurements of total dissolved solids (TDS) or conductivity. pDS Meters™ test conductivity or TDS, plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications, some of which are listed above. Unique Field-Tested Design Our unique, durable, field-tested design has evolved over more than 40 years, making Myron L® instruments among the most reliable and popular of their kind in the world. They’re lightweight and compact, yet Myron L®’s DS and pDS Meters are also tough, with rugged, taut-band meter movements. Put our meters to the test. Even after years of rough field service, they’ll surpass your expectations of accuracy, reliability and simplicity.

Readings You Can Count On

No water supply is completely pure. Every industrial, commercial, or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life.

Myron L® Company has two proven ways to measure such impurities. Our DS Meters™ provide fast, accurate, on-the-spot measurements of total dissolved solids (TDS) or conductivity. pDS Meters™ test conductivity or TDS, plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications, some of which are listed above.

Unique Field-Tested Design

Our unique, durable, field-tested design has evolved over more than 40 years, making Myron L® instruments among the most reliable and popular of their kind in the world. They’re lightweight and compact, yet Myron L®’s DS and pDS Meters are also tough, with rugged, taut-band meter movements. Put our meters to the test. Even after years of rough field service, they’ll surpass your expectations of accuracy, reliability and simplicity.

Supplier's Site Datasheet

Technical Specifications

  Myron L Company
Product Category Conductivity Electrodes
Product Number M6/PH
Product Name pDS Meter
Conductivity Range 0.0 to 5000 MicroSiemens/cm
Unlock Full Specs
to access all available technical data

Similar Products

CONTROLSTIK II System Conductivity Monitor/Controller - 597 - Myron L Company
Specs
Mounting Options Hand Held (Dip) or Portable
Maximum Diameter / Width 7.75 inch (197 mm)
Maximum Length 7.25 inch (184 mm)
View Details
Agri-Meter pDS pH/Conductivity Meter - AG6/PH - Myron L Company
Specs
Electrode Accuracy 2 (+/- % FS)
Mounting Options Hand Held (Dip) or Portable
Maximum Diameter / Width 3.4 inch (86.36 mm)
View Details
750 II Conductivity/TDS Monitor/Controller - 758II - Myron L Company
Specs
Conductivity Range 0.0 to 200 MicroSiemens/cm
Electrode Accuracy 1 (+/- % FS)
Maximum Diameter / Width 4.8 inch (122 mm)
View Details
750 II Conductivity/TDS Monitor/Controller - 754II - Myron L Company
Specs
Conductivity Range 0.0 to 200 MicroSiemens/cm
Electrode Accuracy 1 (+/- % FS)
Maximum Diameter / Width 4.8 inch (122 mm)
View Details