InspectorTools Q32 Digital Duc-Testing System w/Automatic Control REDFQ32120V

Description
Automated Duct Testing without a computer…for measuring duct leakage in residential & light commercial buildings. Standard Equipment Includes: Duc-Tester Module DM-2A Digital gauge 12 foot flex-duct with flanges for mounting on the return register Click on the desired test pressure and walk away; the DM-2A will run the test for you. Case for DM-2A and grill mask dispenser not included. DM-2A adjusts speed and measures duct leakage automatically. The DU220 fan unit has three flow ranges. New Home or Utility Standards The Retrotec Duc-Tester is designed specifically to measure residential duct leakage. It can then be used to locate duct leaks and to measure the results of duct sealing. Use the Model Q32 Duc-Tester to verify duct leakage for compliance with codes such as Title 24 in California. The typical 5 Ton air-conditioning system must have 120 cfm of leakage or less to pass California standards. The Q32 will easily test any residential system because it will create 600 cfm which is 5 times more than that.
Description
Automated Duct Testing without a computer…for measuring duct leakage in residential & light commercial buildings. Standard Equipment Includes: Duc-Tester Module DM-2A Digital gauge 12 foot flex-duct with flanges for mounting on the return register Click on the desired test pressure and walk away; the DM-2A will run the test for you. Case for DM-2A and grill mask dispenser not included. DM-2A adjusts speed and measures duct leakage automatically. The DU220 fan unit has three flow ranges. New Home or Utility Standards The Retrotec Duc-Tester is designed specifically to measure residential duct leakage. It can then be used to locate duct leaks and to measure the results of duct sealing. Use the Model Q32 Duc-Tester to verify duct leakage for compliance with codes such as Title 24 in California. The typical 5 Ton air-conditioning system must have 120 cfm of leakage or less to pass California standards. The Q32 will easily test any residential system because it will create 600 cfm which is 5 times more than that.

Suppliers

Company
Product
Description
Supplier Links
Q32 Digital Duc-Testing System w/Automatic Control - REDFQ32120V - InspectorTools
Ventura, CA, USA
Q32 Digital Duc-Testing System w/Automatic Control
REDFQ32120V
Q32 Digital Duc-Testing System w/Automatic Control REDFQ32120V
Automated Duct Testing without a computer…for measuring duct leakage in residential & light commercial buildings. Standard Equipment Includes: Duc-Tester Module DM-2A Digital gauge 12 foot flex-duct with flanges for mounting on the return register Click on the desired test pressure and walk away; the DM-2A will run the test for you. Case for DM-2A and grill mask dispenser not included. DM-2A adjusts speed and measures duct leakage automatically. The DU220 fan unit has three flow ranges. New Home or Utility Standards The Retrotec Duc-Tester is designed specifically to measure residential duct leakage. It can then be used to locate duct leaks and to measure the results of duct sealing. Use the Model Q32 Duc-Tester to verify duct leakage for compliance with codes such as Title 24 in California. The typical 5 Ton air-conditioning system must have 120 cfm of leakage or less to pass California standards. The Q32 will easily test any residential system because it will create 600 cfm which is 5 times more than that.

Automated Duct Testing without a computer…for measuring duct leakage in residential & light commercial buildings.
Standard Equipment Includes:

  • Duc-Tester Module
  • DM-2A Digital gauge
  • 12 foot flex-duct with flanges for mounting on the return register

Click on the desired test pressure and walk away; the DM-2A will run the test for you. Case for DM-2A and grill mask dispenser not included.
DM-2A adjusts speed and measures duct leakage automatically.
The DU220 fan unit has three flow ranges.
New Home or Utility Standards

    The Retrotec Duc-Tester is designed specifically to measure residential duct leakage. It can then be used to locate duct leaks and to measure the results of duct sealing. Use the Model Q32 Duc-Tester to verify duct leakage for compliance with codes such as Title 24 in California. The typical 5 Ton air-conditioning system must have 120 cfm of leakage or less to pass California standards. The Q32 will easily test any residential system because it will create 600 cfm which is 5 times more than that.
Supplier's Site

Technical Specifications

  InspectorTools
Product Category Leak Testing Equipment
Product Number REDFQ32120V
Product Name Q32 Digital Duc-Testing System w/Automatic Control
Unlock Full Specs
to access all available technical data

Similar Products

Leak detectors - TAPIR HL 2216 A - Busch Vacuum Solutions
Busch Vacuum Solutions
Specs
Leak Test Method Electronic Gas Detection
Local Interface Digital Front Panel
Display Type Digital Readouts
View Details
Flow and Leak Tester - T3LPF - Marposs Corp
Specs
Computer Interface Options Serial Interface
View Details
Ultrasonic Leak Detectors - 2080502 - RS Components, Ltd.
Specs
Leak Test Method Ultrasonic Leak Detector
Display Type Digital Readouts
View Details
HLD MD15 Mobile Dry Helium Leak Detector -  - Agilent Technologies - Vacuum Products
Agilent Technologies - Vacuum Products
Specs
Leak Test Method Mass Spectrometer (Helium Leak Detector)
Output Options Analog Voltage
Local Interface Digital Front Panel
View Details