Description
The EC-Gold gas transmitter is part of the Arjay series of gas detection instruments. This employs electro- chemical sensors to target toxic gas or oxygen concentrations in ambient air. The unique design and flexible interface allows this transmitter to be used with any of the Arjay controllers or directly with your own site automation or control system. • multiple outputs and communications • robust metal housing • wide variety of sensor options The on-board sensor continuously monitors the ambient air by natural diffusion. The sensor responds proportionally to the gas concentration in the air. A signal is sent to the control panel or system for ventilation or alarms.
Request a Quote
Description
The EC-Gold gas transmitter is part of the Arjay series of gas detection instruments. This employs electro- chemical sensors to target toxic gas or oxygen concentrations in ambient air. The unique design and flexible interface allows this transmitter to be used with any of the Arjay controllers or directly with your own site automation or control system. • multiple outputs and communications • robust metal housing • wide variety of sensor options The on-board sensor continuously monitors the ambient air by natural diffusion. The sensor responds proportionally to the gas concentration in the air. A signal is sent to the control panel or system for ventilation or alarms.
Request a Quote
Datasheet
Datasheet Summary
Powered by GS/AI

The EC-Gold is a toxic gas and oxygen transmitter using electrochemical sensors for ambient air monitoring in commercial, residential, and light industrial applications. It features a protective aluminum housing with NEMA/Type 1 (IP40) rating, measures 197mm x 76mm x 76mm, and is designed for surface mounting. The unit operates on 14-24 VDC, provides 4-20 mA and RS-485 Modbus outputs, and supports calibration via an external push button without opening the enclosure. It is approved to CSA and UL standards, functions in temperatures from -20°C to +50°C, and handles humidity levels of 5-90% non-condensing. Sensor options include CO, NO₂, NH₃, H₂S, Cl₂, and O₂, with factory defaults specified for each.

Datasheet Summary
Powered by GS/AI

The EC-Gold is a toxic gas and oxygen transmitter using electrochemical sensors for ambient air monitoring in commercial, residential, and light industrial applications. It features a protective aluminum housing with NEMA/Type 1 (IP40) rating, measures 197mm x 76mm x 76mm, and is designed for surface mounting. The unit operates on 14-24 VDC, provides 4-20 mA and RS-485 Modbus outputs, and supports calibration via an external push button without opening the enclosure. It is approved to CSA and UL standards, functions in temperatures from -20°C to +50°C, and handles humidity levels of 5-90% non-condensing. Sensor options include CO, NO₂, NH₃, H₂S, Cl₂, and O₂, with factory defaults specified for each.

Suppliers

Company
Product
Description
Supplier Links
Toxic Gas/Oxygen Transmitter - EC-Gold - Arjay Engineering
Oakville, Ontario, Canada
Toxic Gas/Oxygen Transmitter
EC-Gold
Toxic Gas/Oxygen Transmitter EC-Gold
The EC-Gold gas transmitter is part of the Arjay series of gas detection instruments. This employs electro- chemical sensors to target toxic gas or oxygen concentrations in ambient air. The unique design and flexible interface allows this transmitter to be used with any of the Arjay controllers or directly with your own site automation or control system. • multiple outputs and communications • robust metal housing • wide variety of sensor options The on-board sensor continuously monitors the ambient air by natural diffusion. The sensor responds proportionally to the gas concentration in the air. A signal is sent to the control panel or system for ventilation or alarms.

The EC-Gold gas transmitter is part of the Arjay series of gas
detection instruments. This employs electro-
chemical sensors to target toxic gas or oxygen
concentrations in ambient air. The unique design
and flexible interface allows this transmitter to
be used with any of the Arjay controllers or
directly with your own site automation or
control system.

• multiple outputs and communications
• robust metal housing
• wide variety of sensor options

The on-board sensor continuously monitors the
ambient air by natural diffusion. The sensor
responds proportionally to the gas concentration
in the air. A signal is sent to the control panel or
system for ventilation or alarms.

Supplier's Site Datasheet

Technical Specifications

  Arjay Engineering
Product Category Gas Instruments
Product Number EC-Gold
Product Name Toxic Gas/Oxygen Transmitter
Measurement Type %Volume; Trace
Application Ambient Air Monitoring
Gas Types Toxic; Combustible; NH3; (0-100ppm); CO; (0-500ppm); Cl2; (0-10ppm); Refrigerants; H2S; (0-100ppm); NO2; (0-20ppm); O2; (0-30%)
Electrical Outputs Current
Features Audible or Visual Alarms
Unlock Full Specs
to access all available technical data

Similar Products

Refrigerant Gas Monitor - 4200-IR - Arjay Engineering
Specs
Measurement Type Trace
Application Ambient Air Monitoring
Gas Types NH3; Refrigerants
View Details
Toxic Gas Transmitter - HLM-2000-TX - Arjay Engineering
Specs
Measurement Type %Volume; Trace
Application Ambient Air Monitoring
Gas Types Toxic; Combustible; NH3; (0-100ppm); CO; (0-500ppm); Cl2; (0-10ppm); HCl; (0-10ppm); H2S; (0-100ppm); NO; (0-100ppm); NO2; (0-20pm); O2; (0-30%); SO2; (0-50ppm)
View Details
Toxic Gas Transmitter - HLM-2000-TX - Arjay Engineering
Specs
Measurement Type %Volume; Trace
Application Ambient Air Monitoring
Gas Types Toxic; Combustible; NH3; (0-100ppm); CO; (0-500ppm); Cl2; (0-10ppm); HCl; (0-10ppm); H2S; (0-100ppm); NO; (0-100ppm); NO2; (0-20pm); O2; (0-30%); SO2; (0-50ppm)
View Details
Industrial Grade Gas Monitor - 4200-IG - Arjay Engineering
Specs
Measurement Type %LEL or %LFL (optional feature); %Volume (optional feature); Trace (optional feature)
Application Ambient Air Monitoring
Gas Types Toxic (optional feature); Combustible (optional feature)
View Details