INTEC Energy Systems SCHNEIDER Three-Pass Boilers w/ Superheated Steam Generation

Description
In order to generate superheated steam, SCHNEIDER-Three Pass Boilers can be equipped with different superheater systems. For lower steam temperatures (superheating by 40 to 60 K), the superheater is installed within the front reversing chamber..This arrangement does not call for any particular measures when starting up the boiler, such as cooling of the superheater or any flue gas side bypass dampers, since the flue gas temperature in the front reversing chamber is significantly below the scaling temperature of the material used for the superheater tubes. These superheaters are called “steam dryers” and are operated without temperature control. For higher steam temperatures, the superheater is installed within the rear reversing chamber. As a result, higher steam temperatures are achieved. A superheater of this temperature level is operated with temperature control, various control systems are available. In order to avoid the superheater tubes to be burnt in this temperature level, the start up must be carried out very carefully. Depending on arrangement and design the start up must be on the lowest possible load before connecting the boiler to the grid, or a sophisticated cooling system must be installed.
Description
In order to generate superheated steam, SCHNEIDER-Three Pass Boilers can be equipped with different superheater systems. For lower steam temperatures (superheating by 40 to 60 K), the superheater is installed within the front reversing chamber..This arrangement does not call for any particular measures when starting up the boiler, such as cooling of the superheater or any flue gas side bypass dampers, since the flue gas temperature in the front reversing chamber is significantly below the scaling temperature of the material used for the superheater tubes. These superheaters are called “steam dryers” and are operated without temperature control. For higher steam temperatures, the superheater is installed within the rear reversing chamber. As a result, higher steam temperatures are achieved. A superheater of this temperature level is operated with temperature control, various control systems are available. In order to avoid the superheater tubes to be burnt in this temperature level, the start up must be carried out very carefully. Depending on arrangement and design the start up must be on the lowest possible load before connecting the boiler to the grid, or a sophisticated cooling system must be installed.

Suppliers

Company
Product
Description
Supplier Links
SCHNEIDER Three-Pass Boilers w/ Superheated Steam Generation -  - INTEC Energy Systems
Bruchsal, Germany
SCHNEIDER Three-Pass Boilers w/ Superheated Steam Generation
SCHNEIDER Three-Pass Boilers w/ Superheated Steam Generation
In order to generate superheated steam, SCHNEIDER-Three Pass Boilers can be equipped with different superheater systems. For lower steam temperatures (superheating by 40 to 60 K), the superheater is installed within the front reversing chamber..This arrangement does not call for any particular measures when starting up the boiler, such as cooling of the superheater or any flue gas side bypass dampers, since the flue gas temperature in the front reversing chamber is significantly below the scaling temperature of the material used for the superheater tubes. These superheaters are called “steam dryers” and are operated without temperature control. For higher steam temperatures, the superheater is installed within the rear reversing chamber. As a result, higher steam temperatures are achieved. A superheater of this temperature level is operated with temperature control, various control systems are available. In order to avoid the superheater tubes to be burnt in this temperature level, the start up must be carried out very carefully. Depending on arrangement and design the start up must be on the lowest possible load before connecting the boiler to the grid, or a sophisticated cooling system must be installed.

In order to generate superheated steam, SCHNEIDER-Three Pass Boilers can be equipped with different superheater systems.

For lower steam temperatures (superheating by 40 to 60 K), the superheater is installed within the front reversing chamber..This arrangement does not call for any particular measures when starting up the boiler, such as cooling of the superheater or any flue gas side bypass dampers, since the flue gas temperature in the front reversing chamber is significantly below the scaling temperature of the material used for the superheater tubes. These superheaters are called “steam dryers” and are operated without temperature control.

For higher steam temperatures, the superheater is installed within the rear reversing chamber. As a result, higher steam temperatures are achieved. A superheater of this temperature level is operated with temperature control, various control systems are available. In order to avoid the superheater tubes to be burnt in this temperature level, the start up must be carried out very carefully.

Depending on arrangement and design the start up must be on the lowest possible load before connecting the boiler to the grid, or a sophisticated cooling system must be installed.

Supplier's Site

Technical Specifications

  INTEC Energy Systems
Product Category Boilers (industrial)
Product Name SCHNEIDER Three-Pass Boilers w/ Superheated Steam Generation
Unlock Full Specs
to access all available technical data

Similar Products

Packaged Hot Water Boilers - HW, VW Series - Thermon, Inc
Specs
Type Hot Water
Orientation Horizontal
Features ASME
View Details
Small Standard Electric Steam Superheaters - ES-25/50/60 Series - Acme Engineering Products
Specs
Type Steam
Technology Steam Generator
Orientation Vertical (optional feature); Horizontal (optional feature)
View Details
 - Tobago (TWZ) - Crown Boiler Co.
Crown Boiler Co.
Specs
Type Hot Water
Technology Cast Iron
Fuel Type / Heat Source Oil
View Details