Fluidwell bv Datasheets for Flow Computers, Totalizers, and Indicators
Flow computers, totalizers, and rate indicators integrate the functions of flow and temperature measurement, computation, data acquisition, input / output (I/O) standardization, and closed loop control. They require external sensor inputs and may be used as local rate indicators.
Flow Computers, Totalizers, and Indicators: Learn more
| Product Name | Notes |
|---|---|
| he F016 is a local indicator which displays the actual flow rate, total and accumulated total. In addition to the average K-Factor or Span, eight linearization points can be entered... | |
| The D010 is a local, panel mount indicator to display the actual flow rate. The measuring and time unit to be displayed are simply selected through an alfa-numerical configuration menu. | |
| The D011 is a local, panel mount indicator to display the running total and accumulated total. Total can be reset to zero by pressing the CLEAR button twice. A non-resettable... | |
| The D012 is a local, panel mount indicator to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button... | |
| The D013 is a versatile, panel mount flow rate indicator and totalizer with continous flow rate monitoring feature. It offers the facility to set one low flow rate and one... | |
| The D014 is a local, panel mount indicator to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button... | |
| The D016 is a loca,l panel mount indicator with linearization to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the... | |
| The D090 is a local, panel mount indicator to display the actual process value, range and loop current. The measuring unit to be displayed is simply selected through an alfa-numerical... | |
| The E018 is one of the top models in our range of explosion proof flow computers. In addition to the average K-Factor, 16 linearization points can be entered. The unit... | |
| The E110 is a popular model in our range of explosion proof flow rate indicators, complete with pulse and analog output signals. The E-series is distinguished by its high quality... | |
| The E112 is a popular model in our range of explosion proof flow rate indicators. In addition to the average K-Factor, 16 linearization points can be entered. The unit will... | |
| The E126-EG delivers accurate measurement while withstanding the harshest conditions. It measures the actual flow, temperature and pressure and converts it with an ideal gas formula to gas volume at... | |
| The E126-EL delivers accurate measurement while withstanding the harshest conditions.The corrected volumetric flow is calculated by using the thermal expansion coefficient algorithm stored in the flowcomputer. The reference temperature can... | |
| The F010 is a local indicator with large 26mm (1") high digits which displays the actual flow rate. The measuring and time unit to be displayed below the flow rate... | |
| The F011 is a local indicator which displays the running total and accumulated total simultaneously. Total can be reset to zero by pressing the CLEAR button twice. The accumulated total... | |
| The F012 is our most popular model. This local indicator displays the actual flow rate, total and accumulated total. Total can be reset to zero by pressing the CLEAR button... | |
| The F013 is a versatile flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the ability to set one low flow rate and one high flow... | |
| The F014 is a local indicator which displays the actual flow rate, total and accumulated total. A scaled pulse, related to the accumulated total is generated for re-transmitting the count... | |
| The F018 is a local indicator with linearization, that displays the actual flow rate, resettable total and non-resettable accumulated total. The F-Series is known worldwide as a range of user-friendly... | |
| The F090-A-PL is an economical loop powered general purpose indicator with large 26mm (1") high digits. The measuring unit to be displayed is simply selected through an alphanumeric configuration menu. | |
| The F093 is a local indicator to monitor the tachometer engine speed with running hours simultaneously. The running hours can be reset to zero by pressing the CLEAR button twice. | |
| The F110 is the most popular model in our range of flow rate / totalizers, complete with pulse and analog output signals. Even demanding applications are catered for with our... | |
| The F111 incorporates two flow rate / totalizers in one enclosure, including a pulse output for each flow. There is no relationship between the flows, even different pulse signal input... | |
| The F112 is a versatile flow rate indicator and totalizer with the ability to precisely linearize the flow meter signal. In addition to the average K-Factor or Span, fifteen linearization... | |
| The F113 is a versatile flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the ability to set two low flow rate and two high flow... | |
| The F114 flow computer calculates the actual ratio between two separate flows. It offers the ability to set one low ratio and one high ratio alarm value. Special precautions are... | |
| The F115 has been developed for applications where the direction of flow is an issue. It is required to offer two pulse signals from the flow meter which are 90° | |
| The F116 flow computer has been developed to calculate differential / consumption or total volume. The usual difficulties encountered in such applications include: pulsating flows, very low consumption readings, vibration... | |
| The F117 has been developed for applications where the totalized quantity has to be monitored and not the flow rate. When a start command is given, the totalizer is reset... | |
| The F118 is a versatile flow rate indicator and totalizer with the ability to precisely linearize the flow meter signal. In addition to the average K-Factor or Span, ten linearization... | |
| The F126-EG flow computer has been developed to calculate corrected gas volume at normal conditions. The corrected volumetric flow is calculated by measuring the uncorrected volumetric flow, actual line temperature... | |
| The F126-EL flow computer has been developed to calculate corrected liquid volume at normal conditions. The corrected volumetric flow is calculated by measuring the uncorrected volumetric flow and actual line... | |
| The F127 flow computer has been developed to calculate corrected differential liquid volume at normal conditions. This is calculated by measuring the uncorrected volumetric flow and actual line temperature in... | |
| The F193 is a versatile large digit Modbus display. All displayed information and signal outputs are controlled through the Modbus ASCII / RTU communication protocol. Information of nine different tanks... | |
| The F195 has been developed for the valve position indication and monitoring in hydraulic systems. By using a bi-directional flow meter to measure the volume displaced by the actuator, an... | |
| The F197 is a manual set-point generator. The operator enters an analog or a scaled output value or a percentage which will be transmitted as a (0)4 – 20mA or... |