TruPosition CM1.25 Certification Masters CM1.25

Description
Description: The CM1.25 Certification Master is used to check and certify the accuracy of the TruPosition Probe. If you have a calibration system and want to maintain files on your TruPosition Probes, then the CM1.25 Certification Master is the best and quickest way to check calibration. CM1.25 The TruPosition Probe must: be set to zero using the Zero Master. be inserted into the Certification Master. be rotated in the Master until the “A” axis reads “0.00.” the “B” axis should read “1.00 +/-.01mm be rotated in the Master until the “B” axis reads “0.00.” the “A” axis should read “1.00 +/-.01mm
Description
Description: The CM1.25 Certification Master is used to check and certify the accuracy of the TruPosition Probe. If you have a calibration system and want to maintain files on your TruPosition Probes, then the CM1.25 Certification Master is the best and quickest way to check calibration. CM1.25 The TruPosition Probe must: be set to zero using the Zero Master. be inserted into the Certification Master. be rotated in the Master until the “A” axis reads “0.00.” the “B” axis should read “1.00 +/-.01mm be rotated in the Master until the “B” axis reads “0.00.” the “A” axis should read “1.00 +/-.01mm

Suppliers

Company
Product
Description
Supplier Links
CM1.25 Certification Masters - CM1.25 - TruPosition
Wyoming, MI, United States
CM1.25 Certification Masters
CM1.25
CM1.25 Certification Masters CM1.25
Description: The CM1.25 Certification Master is used to check and certify the accuracy of the TruPosition Probe. If you have a calibration system and want to maintain files on your TruPosition Probes, then the CM1.25 Certification Master is the best and quickest way to check calibration. CM1.25 The TruPosition Probe must: be set to zero using the Zero Master. be inserted into the Certification Master. be rotated in the Master until the “A” axis reads “0.00.” the “B” axis should read “1.00 +/-.01mm be rotated in the Master until the “B” axis reads “0.00.” the “A” axis should read “1.00 +/-.01mm

Description:

The CM1.25 Certification Master is used to check and certify the accuracy of the TruPosition Probe. If you have a calibration system and want to maintain files on your TruPosition Probes, then the CM1.25 Certification Master is the best and quickest way to check calibration.

CM1.25

The TruPosition Probe must:

  1. be set to zero using the Zero Master.
  2. be inserted into the Certification Master.
  3. be rotated in the Master until the “A” axis reads “0.00.” the “B” axis should read “1.00 +/-.01mm
  4. be rotated in the Master until the “B” axis reads “0.00.” the “A” axis should read “1.00 +/-.01mm
Supplier's Site

Technical Specifications

  TruPosition
Product Category Dimensional Gages and Instruments
Product Number CM1.25
Product Name CM1.25 Certification Masters
Gage / Instrument Type Gage Block, Master, or Setting Gage
Unlock Full Specs
to access all available technical data

Similar Products

Premium Short Shank Inspection Balls - 29068 - Jergens, Inc.
Specs
Measurement Scale / Units English
View Details
Flatness Measurement, Standard Measuring Roll -  - ABB Measurement & Analytics
Specs
Measurement Scale / Units Metric
Gage / Instrument Type Gaging System or Station
Range 1.02 to 2.05 inch (26 to 52 mm)
View Details
Fitting Identification Tool (Metric/British) -  - HydraCheck Inc.
Specs
Mounting / Loading Options Handheld or Portable
Measurement Scale / Units English; Metric
Gaging Technology Mechanical
View Details
Linear Distance Measuring System - Model U304393 - Pratt & Whitney Measurement Systems, Inc.
Pratt & Whitney Measurement Systems, Inc.
Specs
Mounting / Loading Options Benchtop or Floor
Measurement Scale / Units English; Metric
Gage / Instrument Type Gaging System or Station; Indicator / Comparator; Micrometer; Length
View Details