Taylor Dynamometer, Inc. Mass Airflow Meter

Description
The Taylor Dynamometer Mass Air Flow Meter is designed to work with the DynPro Data Acquisition and Control System. This meter measures the amount of intake air consumed by an engine. Using the Pitot principle to measure the total and static pressure components of airflow, the pressure sensing ports sense the impact pressure of the approaching air stream allowing the transmitter to determine the volumetric flow of air. With the ports positioned at designated angles, the meter assures accurate measurement of the sensed airflow rate and eliminates the need for an airflow straightener upstream. The transmitter provides an automatic zeroing circuit capable of electronically adjusting the transmitter to zero at predetermined time intervals while simultaneously holding the transmitter output signal. The automatic zeroing circuit eliminates all output signal drift due to thermal, electronic or mechanical effects, as well as the need for initial or periodic transmitter zeroing. For Mass Air Flow Meters operated in temperature controlled spaces (with no thermal effect upon span), this automatic zeroing function essentially produces a "self calibrating" transmitter.
Description
The Taylor Dynamometer Mass Air Flow Meter is designed to work with the DynPro Data Acquisition and Control System. This meter measures the amount of intake air consumed by an engine. Using the Pitot principle to measure the total and static pressure components of airflow, the pressure sensing ports sense the impact pressure of the approaching air stream allowing the transmitter to determine the volumetric flow of air. With the ports positioned at designated angles, the meter assures accurate measurement of the sensed airflow rate and eliminates the need for an airflow straightener upstream. The transmitter provides an automatic zeroing circuit capable of electronically adjusting the transmitter to zero at predetermined time intervals while simultaneously holding the transmitter output signal. The automatic zeroing circuit eliminates all output signal drift due to thermal, electronic or mechanical effects, as well as the need for initial or periodic transmitter zeroing. For Mass Air Flow Meters operated in temperature controlled spaces (with no thermal effect upon span), this automatic zeroing function essentially produces a "self calibrating" transmitter.

Suppliers

Company
Product
Description
Supplier Links
Mass Airflow Meter -  - Taylor Dynamometer, Inc.
Milwaukee, WI, USA
Mass Airflow Meter
Mass Airflow Meter
The Taylor Dynamometer Mass Air Flow Meter is designed to work with the DynPro Data Acquisition and Control System. This meter measures the amount of intake air consumed by an engine. Using the Pitot principle to measure the total and static pressure components of airflow, the pressure sensing ports sense the impact pressure of the approaching air stream allowing the transmitter to determine the volumetric flow of air. With the ports positioned at designated angles, the meter assures accurate measurement of the sensed airflow rate and eliminates the need for an airflow straightener upstream. The transmitter provides an automatic zeroing circuit capable of electronically adjusting the transmitter to zero at predetermined time intervals while simultaneously holding the transmitter output signal. The automatic zeroing circuit eliminates all output signal drift due to thermal, electronic or mechanical effects, as well as the need for initial or periodic transmitter zeroing. For Mass Air Flow Meters operated in temperature controlled spaces (with no thermal effect upon span), this automatic zeroing function essentially produces a "self calibrating" transmitter.

The Taylor Dynamometer Mass Air Flow Meter is designed to work with the DynPro Data Acquisition and Control System. This meter measures the amount of intake air consumed by an engine. Using the Pitot principle to measure the total and static pressure components of airflow, the pressure sensing ports sense the impact pressure of the approaching air stream allowing the transmitter to determine the volumetric flow of air. With the ports positioned at designated angles, the meter assures accurate measurement of the sensed airflow rate and eliminates the need for an airflow straightener upstream. The transmitter provides an automatic zeroing circuit capable of electronically adjusting the transmitter to zero at predetermined time intervals while simultaneously holding the transmitter output signal. The automatic zeroing circuit eliminates all output signal drift due to thermal, electronic or mechanical effects, as well as the need for initial or periodic transmitter zeroing. For Mass Air Flow Meters operated in temperature controlled spaces (with no thermal effect upon span), this automatic zeroing function essentially produces a "self calibrating" transmitter.

Supplier's Site

Technical Specifications

  Taylor Dynamometer, Inc.
Product Category Flow Meters
Product Name Mass Airflow Meter
Meter Type Mass Flow Meter
Unlock Full Specs
to access all available technical data

Similar Products

Open Channel Flow Meter - UFL9000 - Holykell Technology Company Limited
Holykell Technology Company Limited
Specs
Operating Temperature -4 to 140 F (-20 to 60 C)
Process Media Type Liquid
Display Digital
View Details
FlatTrak™ 780S-UHP Ultra High Purity In-line Mass Flow Meter with Flow Conduit -  - Sierra Instruments, Inc.
Specs
Meter Technology Thermal
Meter Type Mass Flow Meter; Volumetric Flow Meter
Features Built-in Alarm Indicator; Programmable; Recorder / Totalizer Functions
View Details
Universal Flow Meter Test Kits -  - HydraCheck Inc.
Specs
Meter Type Volumetric Flow Meter
Process Media Type Liquid
Liquid Volumetric Flow Rate 1.00 to 100.00 GPM (3.79 to 379 L/min)
View Details
FLATREG MFC - 40M0401CJ1811 311000 - IMI Life Science
Specs
Meter Type Mass Flow Meter
Process Media Type Gas
View Details