StellarNet, Inc. BLACK-Comet C-SR Plus RED-Wave-NIR-512 DSR-CSR-512

Description
StellarNet Dual-DSR spectrometer systems combine two instruments to cover the ultra violet, visible and near infrared portions of the electromagnetic spectrum. The two instruments work as one creating a unified spectral graph over the entire wavelength region, 200-2300nm. The two instruments employ both a UV-VIS detector array and NIR-InGaAs array in order to cover the entire range. 2048 element UV-VIS detector with the option of 512 or 1024 elements in the NIR. Various models allow for ranges from 200-1700, 280-1700, or 200-2300nm depending in the measurement specifications required. Like always StellarNet spectrometers are ruggedized for field or lab process measurements. A Miniature USB-Hub provides instrument PC interface. The Dual-DSR system has many applications for spectroradiometry, food and drug QA/QC, and chemical process measurements due to its ability to probe the near infrared while simultaneously measuring sample UV and color spectrum.
Description
StellarNet Dual-DSR spectrometer systems combine two instruments to cover the ultra violet, visible and near infrared portions of the electromagnetic spectrum. The two instruments work as one creating a unified spectral graph over the entire wavelength region, 200-2300nm. The two instruments employ both a UV-VIS detector array and NIR-InGaAs array in order to cover the entire range. 2048 element UV-VIS detector with the option of 512 or 1024 elements in the NIR. Various models allow for ranges from 200-1700, 280-1700, or 200-2300nm depending in the measurement specifications required. Like always StellarNet spectrometers are ruggedized for field or lab process measurements. A Miniature USB-Hub provides instrument PC interface. The Dual-DSR system has many applications for spectroradiometry, food and drug QA/QC, and chemical process measurements due to its ability to probe the near infrared while simultaneously measuring sample UV and color spectrum.

Suppliers

Company
Product
Description
Supplier Links
BLACK-Comet C-SR Plus RED-Wave-NIR-512 - DSR-CSR-512 - StellarNet, Inc.
Tampa, FL, USA
BLACK-Comet C-SR Plus RED-Wave-NIR-512
DSR-CSR-512
BLACK-Comet C-SR Plus RED-Wave-NIR-512 DSR-CSR-512
StellarNet Dual-DSR spectrometer systems combine two instruments to cover the ultra violet, visible and near infrared portions of the electromagnetic spectrum. The two instruments work as one creating a unified spectral graph over the entire wavelength region, 200-2300nm. The two instruments employ both a UV-VIS detector array and NIR-InGaAs array in order to cover the entire range. 2048 element UV-VIS detector with the option of 512 or 1024 elements in the NIR. Various models allow for ranges from 200-1700, 280-1700, or 200-2300nm depending in the measurement specifications required. Like always StellarNet spectrometers are ruggedized for field or lab process measurements. A Miniature USB-Hub provides instrument PC interface. The Dual-DSR system has many applications for spectroradiometry, food and drug QA/QC, and chemical process measurements due to its ability to probe the near infrared while simultaneously measuring sample UV and color spectrum.

StellarNet Dual-DSR spectrometer systems combine two instruments to cover the ultra violet, visible and near infrared portions of the electromagnetic spectrum. The two instruments work as one creating a unified spectral graph over the entire wavelength region, 200-2300nm. The two instruments employ both a UV-VIS detector array and NIR-InGaAs array in order to cover the entire range. 2048 element UV-VIS detector with the option of 512 or 1024 elements in the NIR. Various models allow for ranges from 200-1700, 280-1700, or 200-2300nm depending in the measurement specifications required. Like always StellarNet spectrometers are ruggedized for field or lab process measurements. A Miniature USB-Hub provides instrument PC interface. The Dual-DSR system has many applications for spectroradiometry, food and drug QA/QC, and chemical process measurements due to its ability to probe the near infrared while simultaneously measuring sample UV and color spectrum.

Supplier's Site

Technical Specifications

  StellarNet, Inc.
Product Category Weather Instruments
Product Number DSR-CSR-512
Product Name BLACK-Comet C-SR Plus RED-Wave-NIR-512
Device Classification Sensor System
Weather Component Sensed Measures solar Radiation
Interface Options Parallel digital signal (i.e., PC parallel printer port, GPIB etc.); Digital signal interface other than parallel or serial (i.e., discrete signals, special TTL)
Instrument Display Options Video Display (CRT etc.)
Unlock Full Specs
to access all available technical data

Similar Products

Climate Meter - PCE-THB 40 - PCE Instruments / PCE Americas Inc.
PCE Instruments / PCE Americas Inc.
Specs
Device Classification Sensor System
Weather Component Sensed Measures Temperature; Measures Barometric Pressure; Measures % Relative Humidity
Instrument Display Options Digital Display
View Details
 - 8766001 - RS Components, Ltd.
RS Components, Ltd.
Specs
Weather Component Sensed Measures Barometric Pressure
Features Battery Powered
View Details
Specs
Device Classification Sensor Only
Weather Component Sensed Measures %Water or %Moisture Content
Output Options Outputs an analog voltage signal (optional feature); Outputs an analog current signal (i.e., 4-20 mA) (optional feature)
View Details
Humidity and Temperature Sensor for Demanding Climate Control - EE210 - E+E Elektronik
Specs
Device Classification Sensor Only
Weather Component Sensed Measures Temperature; Measures % Relative Humidity
Output Options Outputs an analog voltage signal (optional feature); Outputs an analog current signal (i.e., 4-20 mA) (optional feature)
View Details