Softing Industrial Automation GmbH Ethernet/IP to PROFIBUS DP/PA Master Gateway epGate PB

Description
With epGate PB it is possible to integrate up to 2 PROFIBUS PA segments and 1 PROFIBUS DP segment into Ethernet/IP systems. With epGate PB the engineering costs can be reduced since it re-uses existing power conditioners in technology upgrade projects. It enables configuration, parameterization and plant asset management using standard industry tools. Key Component for Transition to State-of-the-Art Technology Simple replacement of installed PROFIBUS DP/PA segment coupler Re-use of existing PROFIBUS segments without requiring modification Support of common control systems e.g. Emerson DetlaV or Rockwell Control Logix Support of DLR for redundant communication in the ring with EtherNet/IP Direct Connectivity to PROFIBUS Segments Single access point to PROFIBUS DP and PROFIBUS PA segments from EtherNet/IP networks Acting as EtherNet/IP device (adapter), PROFIBUS PA and PROFIBUS DP Master Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools Supports major EtherNet/IP engineering tools such as Studio 5000 and AMS Device Manager Included CommDTM allowing use in FDT/DTM frame applications EDD-based device parametrization using Siemens Simatic PDM Simple Integration Through Add-On Instructions Data access of PLC program to PROFIBUS devices without requiring detailed PROFIBUS knowledge Mapping between the two protocols generated by provided tools Use of Add-On Instructions (AOI) containing detailed PROFIBUS data type definitions Transparent communication overcoming protocol differences Optimized for usage with Allen Bradley controllers
Datasheet
Description
With epGate PB it is possible to integrate up to 2 PROFIBUS PA segments and 1 PROFIBUS DP segment into Ethernet/IP systems. With epGate PB the engineering costs can be reduced since it re-uses existing power conditioners in technology upgrade projects. It enables configuration, parameterization and plant asset management using standard industry tools. Key Component for Transition to State-of-the-Art Technology Simple replacement of installed PROFIBUS DP/PA segment coupler Re-use of existing PROFIBUS segments without requiring modification Support of common control systems e.g. Emerson DetlaV or Rockwell Control Logix Support of DLR for redundant communication in the ring with EtherNet/IP Direct Connectivity to PROFIBUS Segments Single access point to PROFIBUS DP and PROFIBUS PA segments from EtherNet/IP networks Acting as EtherNet/IP device (adapter), PROFIBUS PA and PROFIBUS DP Master Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools Supports major EtherNet/IP engineering tools such as Studio 5000 and AMS Device Manager Included CommDTM allowing use in FDT/DTM frame applications EDD-based device parametrization using Siemens Simatic PDM Simple Integration Through Add-On Instructions Data access of PLC program to PROFIBUS devices without requiring detailed PROFIBUS knowledge Mapping between the two protocols generated by provided tools Use of Add-On Instructions (AOI) containing detailed PROFIBUS data type definitions Transparent communication overcoming protocol differences Optimized for usage with Allen Bradley controllers
Datasheet

Suppliers

Company
Product
Description
Supplier Links
Ethernet/IP to PROFIBUS DP/PA Master Gateway - epGate PB - Softing Industrial Automation GmbH
Haar, Germany
Ethernet/IP to PROFIBUS DP/PA Master Gateway
epGate PB
Ethernet/IP to PROFIBUS DP/PA Master Gateway epGate PB
With epGate PB it is possible to integrate up to 2 PROFIBUS PA segments and 1 PROFIBUS DP segment into Ethernet/IP systems. With epGate PB the engineering costs can be reduced since it re-uses existing power conditioners in technology upgrade projects. It enables configuration, parameterization and plant asset management using standard industry tools. Key Component for Transition to State-of-the-Art Technology Simple replacement of installed PROFIBUS DP/PA segment coupler Re-use of existing PROFIBUS segments without requiring modification Support of common control systems e.g. Emerson DetlaV or Rockwell Control Logix Support of DLR for redundant communication in the ring with EtherNet/IP Direct Connectivity to PROFIBUS Segments Single access point to PROFIBUS DP and PROFIBUS PA segments from EtherNet/IP networks Acting as EtherNet/IP device (adapter), PROFIBUS PA and PROFIBUS DP Master Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools Supports major EtherNet/IP engineering tools such as Studio 5000 and AMS Device Manager Included CommDTM allowing use in FDT/DTM frame applications EDD-based device parametrization using Siemens Simatic PDM Simple Integration Through Add-On Instructions Data access of PLC program to PROFIBUS devices without requiring detailed PROFIBUS knowledge Mapping between the two protocols generated by provided tools Use of Add-On Instructions (AOI) containing detailed PROFIBUS data type definitions Transparent communication overcoming protocol differences Optimized for usage with Allen Bradley controllers

With epGate PB it is possible to integrate up to 2 PROFIBUS PA segments and 1 PROFIBUS DP segment into Ethernet/IP systems. With epGate PB the engineering costs can be reduced since it re-uses existing power conditioners in technology upgrade projects. It enables configuration, parameterization and plant asset management using standard industry tools.

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment coupler
  • Re-use of existing PROFIBUS segments without requiring modification
  • Support of common control systems e.g. Emerson DetlaV or Rockwell Control Logix
  • Support of DLR for redundant communication in the ring with EtherNet/IP

Direct Connectivity to PROFIBUS Segments

  • Single access point to PROFIBUS DP and PROFIBUS PA segments from EtherNet/IP networks
  • Acting as EtherNet/IP device (adapter), PROFIBUS PA and PROFIBUS DP Master
  • Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major EtherNet/IP engineering tools such as Studio 5000 and AMS Device Manager
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM

Simple Integration Through Add-On Instructions

  • Data access of PLC program to PROFIBUS devices without requiring detailed PROFIBUS knowledge
  • Mapping between the two protocols generated by provided tools
  • Use of Add-On Instructions (AOI) containing detailed PROFIBUS data type definitions
  • Transparent communication overcoming protocol differences
  • Optimized for usage with Allen Bradley controllers
Supplier's Site Datasheet

Technical Specifications

  Softing Industrial Automation GmbH
Product Category Network Equipment
Product Number epGate PB
Product Name Ethernet/IP to PROFIBUS DP/PA Master Gateway
Network Equipment Gateway
Unlock Full Specs
to access all available technical data

Similar Products

RAD Data Communications Short Range Async Modem - SRM-5D/M/TB - Classic Automation LLC
Specs
Network Equipment Modem
View Details
10 Gbit Ethernet SFP+, 850nm multimode - 1-G065 - Hottinger Brüel & Kjær A/S
Specs
Network Equipment Transceiver
View Details
Factor 201 Raspberry Pi Industrial IoT Gateway - FR201 - OnLogic Inc.
Specs
Network Equipment Gateway
Number of Ports 2 #
View Details
DIN Rail Mount RS-485 Repeater - SCM9B-D192 - Dataforth Corporation
Specs
Network Equipment Repeater
Protocol / Network Serial RS-485
Ports / Interfaces Serial
View Details