Sensidyne, LP SensAlert Plus 3-Wire GP Transmitter 820-0202-01

Description
Smart Sensor Technology enables SensAlertPlus to automatically recognize and configure to the gas type and range of the sensor, using the latest calibration data. The Predictive Sensor Failure (PSF) function provides warning of approaching sensor end-of-life. Non-volatile memory stores calibration date and time, operating parameters, default settings and PSF values.
Description
Smart Sensor Technology enables SensAlertPlus to automatically recognize and configure to the gas type and range of the sensor, using the latest calibration data. The Predictive Sensor Failure (PSF) function provides warning of approaching sensor end-of-life. Non-volatile memory stores calibration date and time, operating parameters, default settings and PSF values.

Suppliers

Company
Product
Description
Supplier Links
SensAlert Plus 3-Wire GP Transmitter - 820-0202-01 - Sensidyne, LP
Clearwater, FL, USA
SensAlert Plus 3-Wire GP Transmitter
820-0202-01
SensAlert Plus 3-Wire GP Transmitter 820-0202-01
Smart Sensor Technology enables SensAlertPlus to automatically recognize and configure to the gas type and range of the sensor, using the latest calibration data. The Predictive Sensor Failure (PSF) function provides warning of approaching sensor end-of-life. Non-volatile memory stores calibration date and time, operating parameters, default settings and PSF values.

Smart Sensor Technology enables SensAlertPlus to automatically recognize and configure to the gas type and range of the sensor, using the latest calibration data. The Predictive Sensor Failure (PSF) function provides warning of approaching sensor end-of-life. Non-volatile memory stores calibration date and time, operating parameters, default settings and PSF values.

Supplier's Site

Technical Specifications

  Sensidyne, LP
Product Category Gas Instruments
Product Number 820-0202-01
Product Name SensAlert Plus 3-Wire GP Transmitter
Measurement Type %LEL or %LFL; %Volume; Trace
Application Personal Exposure Monitoring; Confined Space Entry; Continuous Emissions Monitoring; Ambient Air Monitoring; Process Gas
Gas Types Toxic; Combustible; CO2; (0-5%Volume); CO; (0-500ppm); Cl2; (0-10ppm); Hydrocarbons; (0-100%LEL); H2; (0-1000ppm); HCl; (0-21); HCN; (0-20ppm); HF; (0-21); H2S; (0-100ppm); O2; (0-25%Volume); SO2; (0-20ppm)
Electrical Outputs Current
Display Digital
Unlock Full Specs
to access all available technical data

Similar Products

Airborne Particle-Counting Hygiene Meter - PCE-RCM 12 - PCE Instruments / PCE Americas Inc.
Specs
Gas Types Toxic; Combustible; CO2; (0 ... 9999 ppm); Water Vapor; (0 ... 100 % r.H.); (Formaldehyde (HCHO))
Display Digital
Instrument Type Detector
View Details
Multi Sensor Diffusion Based Monitoring System - Model SA-4DS - Safeguard Analytics
Specs
Measurement Type %LEL or %LFL; %Volume; Trace; Leakage
Application Personal Exposure Monitoring; Confined Space Entry; Continuous Emissions Monitoring; Ambient Air Monitoring
Gas Types Toxic; Combustible; (Oxygen Deficiency, VOCs, Refrigerants)
View Details
Air Quality Monitors - 1746575 - RS Components, Ltd.
Specs
Display Digital
Sensor Technology Air quality meter
View Details
NO2 /NO Converter - ZDL03 Series - Fuji Electric Corp. of America
Fuji Electric Corp. of America
Specs
Application Confined Space Entry
Gas Types NO; NO2
Mounting Type Fixed
View Details