Sensidyne, LP Four Channel Controller 7013227-1

Description
Four Channel Controller • NEMA 4X, UL Listed Enclosure • 115/230 VAC or 24 VDC • Visual and Audible Annunciation • Discrete LED and LCD Displays • Automatic Sensor Recognition • Twelve SPDT 5 amp Alarm Relays • Common Fault Alarm Relay • 4-20 mA & RS-485 Outputs
Description
Four Channel Controller • NEMA 4X, UL Listed Enclosure • 115/230 VAC or 24 VDC • Visual and Audible Annunciation • Discrete LED and LCD Displays • Automatic Sensor Recognition • Twelve SPDT 5 amp Alarm Relays • Common Fault Alarm Relay • 4-20 mA & RS-485 Outputs

Suppliers

Company
Product
Description
Supplier Links
Clearwater, FL, USA
Four Channel Controller
7013227-1
Four Channel Controller 7013227-1
Four Channel Controller • NEMA 4X, UL Listed Enclosure • 115/230 VAC or 24 VDC • Visual and Audible Annunciation • Discrete LED and LCD Displays • Automatic Sensor Recognition • Twelve SPDT 5 amp Alarm Relays • Common Fault Alarm Relay • 4-20 mA & RS-485 Outputs

Four Channel Controller

• NEMA 4X, UL Listed Enclosure
• 115/230 VAC or 24 VDC
• Visual and Audible Annunciation
• Discrete LED and LCD Displays
• Automatic Sensor Recognition
• Twelve SPDT 5 amp Alarm Relays
• Common Fault Alarm Relay
• 4-20 mA & RS-485 Outputs

Supplier's Site

Technical Specifications

  Sensidyne, LP
Product Category Gas Instruments
Product Number 7013227-1
Product Name Four Channel Controller
Measurement Type %LEL or %LFL; %Volume; Trace
Application Personal Exposure Monitoring; Confined Space Entry; Continuous Emissions Monitoring; Ambient Air Monitoring; Process Gas
Gas Types Toxic; Combustible
Electrical Outputs Current
Display Digital
Unlock Full Specs
to access all available technical data

Similar Products

GTD-5000 Single-Point Gas Detector -  - DOD Technologies Inc.
Specs
Display Digital
Features Audible or Visual Alarms; Data Logger
Instrument Type Detector
View Details
HVAC Gas Monitor - Z-Gard® DS MPO Dual Gas Sensor - MSA Safety
Specs
Measurement Type Trace
Application Ambient Air Monitoring
Gas Types Toxic; CO; (0-100 ppm, 0-200 ppm); NO2; (0-10 ppm)
View Details
Gas Detector - Model SA-220 - Safeguard Analytics
Safeguard Analytics
Specs
Measurement Type %LEL or %LFL; %Volume; Trace; Leakage
Application Personal Exposure Monitoring; Confined Space Entry; Continuous Emissions Monitoring; Ambient Air Monitoring
Gas Types Toxic; Combustible; (Oxygen Deficiency, VOCs, Refrigerants)
View Details
Propane (C3H8) Combustible Fixed Gas Detector (0-100% LEL) -  - CO2Meter.com
Specs
Gas Types Combustible; (Combustible Fixed Gas Detectors - Propane (C3H8) Combustible Fixed Gas Detector (0-100% LEL))
Number of Gases Monitored Single
Operating Temperature -30 to 122 F (-34 to 50 C)
View Details