Real Tech, Inc. REAL CONDUCTIVITY SENSOR CON1000

Description
Real Tech’s Conductivity sensor measurement is based on the use of 4 electrodes (2 graphic and 2 platinum). An alternating current of constant voltage is established between the graphic pair of electrodes. The voltage measured between these electrodes is a function of resistance, and therefore, conductivity. The platinum electrodes regulate voltage to prevent fouling of the graphic electrodes. This robust sensor is watertight and can be used in multiple applications, wastewater to high purity. 4 electrodes technology Range 0 to 200 mS/cm Robust and Watertight Ultra-low power requirements
Datasheet
Description
Real Tech’s Conductivity sensor measurement is based on the use of 4 electrodes (2 graphic and 2 platinum). An alternating current of constant voltage is established between the graphic pair of electrodes. The voltage measured between these electrodes is a function of resistance, and therefore, conductivity. The platinum electrodes regulate voltage to prevent fouling of the graphic electrodes. This robust sensor is watertight and can be used in multiple applications, wastewater to high purity. 4 electrodes technology Range 0 to 200 mS/cm Robust and Watertight Ultra-low power requirements
Datasheet

Suppliers

Company
Product
Description
Supplier Links
REAL CONDUCTIVITY SENSOR - CON1000 - Real Tech, Inc.
Whitby, Ontario, Canada
REAL CONDUCTIVITY SENSOR
CON1000
REAL CONDUCTIVITY SENSOR CON1000
Real Tech’s Conductivity sensor measurement is based on the use of 4 electrodes (2 graphic and 2 platinum). An alternating current of constant voltage is established between the graphic pair of electrodes. The voltage measured between these electrodes is a function of resistance, and therefore, conductivity. The platinum electrodes regulate voltage to prevent fouling of the graphic electrodes. This robust sensor is watertight and can be used in multiple applications, wastewater to high purity. 4 electrodes technology Range 0 to 200 mS/cm Robust and Watertight Ultra-low power requirements

Real Tech’s Conductivity sensor measurement is based on the use of 4 electrodes (2 graphic and 2 platinum). An alternating current of constant voltage is established between the graphic pair of electrodes. The voltage measured between these electrodes is a function of resistance, and therefore, conductivity. The platinum electrodes regulate voltage to prevent fouling of the graphic electrodes. This robust sensor is watertight and can be used in multiple applications, wastewater to high purity.


  • 4 electrodes technology
  • Range 0 to 200 mS/cm
  • Robust and Watertight
  • Ultra-low power requirements
Supplier's Site Datasheet

Technical Specifications

  Real Tech, Inc.
Product Category Water Quality Testing Instruments
Product Number CON1000
Product Name REAL CONDUCTIVITY SENSOR
Water Quality Parameters Water Quality Measurement Instrument; Measures Conductivity / Dissolved Solids
Unlock Full Specs
to access all available technical data

Similar Products

Benchtop ppm Oil-in-Water - FluoroCheck II - Arjay Engineering
Specs
Water Quality Parameters Water Quality Measurement Instrument; Oil/Water
Form Factor Portable; Lab / Benchtop
Oil in Water Monitor 0 to 500 ppm
View Details
UviTec UV254 Probe -  - ABB Measurement & Analytics
ABB Measurement & Analytics
Specs
Water Quality Parameters Water Quality Measurement Instrument
Features and Functionality Self-test / Diagnostics
Display Type None
View Details
PCE Instruments / PCE Americas Inc.
Specs
Water Quality Parameters Water Quality Measurement Instrument; pH
Form Factor Hand Held ; Portable
Features and Functionality Battery Powered
View Details
Pool/Spa AHL Water Quality Meter & kit - POOLPRO™ PS9TKB - Myron L Company
Specs
Water Quality Parameters Water Quality Measurement Instrument; pH; Measures ORP/Redox; Measures Conductivity / Dissolved Solids; Suspended Solids
Form Factor Hand Held ; Portable
Features and Functionality Battery Powered
View Details