Reznor Reznor® MAPSIII Series Packaged Rooftop Units Model RDCB720

Description
The MAPS® III Series packaged rooftop units are designed to cool, dehumidify, and heat high volumes of outside air year round for makeup air and ventilation applications. In addition, MAPS III can provide significant capacities of space conditioning. The RDCB utilizes environmentally-frie ndly R-410A refrigerant in all circuits for higher efficiency, and to be covered under changing regulations. Model RDCB units are designed to provide an average cooling supply air temperature of 50° to 55°F in humid to temperate climates with superior gas heating modulation - up to 16:1 during winter operation. The model RDCB units are designed from the ground up to handle the realities of outside air heating and cooling. They have multiple stages of cooling for exceptional part-load performance and either staged heat or advanced high efficiency 8:1 electronic modulation. They have the most technologically advanced controls and flexibility for application in BMS networks as well as stand alone configurations. The forward curved and plenum fans can handle high static pressures.
Description
The MAPS® III Series packaged rooftop units are designed to cool, dehumidify, and heat high volumes of outside air year round for makeup air and ventilation applications. In addition, MAPS III can provide significant capacities of space conditioning. The RDCB utilizes environmentally-frie ndly R-410A refrigerant in all circuits for higher efficiency, and to be covered under changing regulations. Model RDCB units are designed to provide an average cooling supply air temperature of 50° to 55°F in humid to temperate climates with superior gas heating modulation - up to 16:1 during winter operation. The model RDCB units are designed from the ground up to handle the realities of outside air heating and cooling. They have multiple stages of cooling for exceptional part-load performance and either staged heat or advanced high efficiency 8:1 electronic modulation. They have the most technologically advanced controls and flexibility for application in BMS networks as well as stand alone configurations. The forward curved and plenum fans can handle high static pressures.

Suppliers

Company
Product
Description
Supplier Links
Reznor® MAPSIII Series Packaged Rooftop Units - Model RDCB720 - Reznor
Memphis, TN, USA
Reznor® MAPSIII Series Packaged Rooftop Units
Model RDCB720
Reznor® MAPSIII Series Packaged Rooftop Units Model RDCB720
The MAPS® III Series packaged rooftop units are designed to cool, dehumidify, and heat high volumes of outside air year round for makeup air and ventilation applications. In addition, MAPS III can provide significant capacities of space conditioning. The RDCB utilizes environmentally-frie ndly R-410A refrigerant in all circuits for higher efficiency, and to be covered under changing regulations. Model RDCB units are designed to provide an average cooling supply air temperature of 50° to 55°F in humid to temperate climates with superior gas heating modulation - up to 16:1 during winter operation. The model RDCB units are designed from the ground up to handle the realities of outside air heating and cooling. They have multiple stages of cooling for exceptional part-load performance and either staged heat or advanced high efficiency 8:1 electronic modulation. They have the most technologically advanced controls and flexibility for application in BMS networks as well as stand alone configurations. The forward curved and plenum fans can handle high static pressures.

The MAPS® III Series packaged rooftop units are designed to cool, dehumidify, and heat high volumes of outside air year round for makeup air and ventilation applications. In addition, MAPS III can provide significant capacities of space conditioning. The RDCB utilizes environmentally-friendly R-410A refrigerant in all circuits for higher efficiency, and to be covered under changing regulations. Model RDCB units are designed to provide an average cooling supply air temperature of 50° to 55°F in humid to temperate climates with superior gas heating modulation - up to 16:1 during winter operation. The model RDCB units are designed from the ground up to handle the realities of outside air heating and cooling. They have multiple stages of cooling for exceptional part-load performance and either staged heat or advanced high efficiency 8:1 electronic modulation. They have the most technologically advanced controls and flexibility for application in BMS networks as well as stand alone configurations. The forward curved and plenum fans can handle high static pressures.

Supplier's Site

Technical Specifications

  Reznor
Product Category Industrial Heaters
Product Number Model RDCB720
Product Name Reznor® MAPSIII Series Packaged Rooftop Units
Heater Type Air Heater; ForcedAir; RoomSpace; Specialty Industrial Heaters; 100% O/A Heating/Cooling/MUA System
Unlock Full Specs
to access all available technical data

Similar Products

Tape Heater - AWH Series - Backer Hotwatt Inc.
Backer Hotwatt Inc.
Specs
Heater Type Flexible Heater
Fuel / Energy Source Electric
Maximum Operating Temperature 1400 F (760 C)
View Details
EKOHEAT Induction Heater - 125/25 - Ambrell Induction Heating Solutions
Ambrell Induction Heating Solutions
Specs
Heater Type Induction
Fuel / Energy Source Electric
Heating Capacity 125.00 kW (426 MBH)
View Details
Tube & Pipe End Heating System - IROSS™ Fluxmanager® Phase 3™ - Inductotherm Group
Specs
Heater Type Induction
Fuel / Energy Source Electric
Phase Three Phase AC Voltage
View Details
Finned Tubular Heating -  - WATTCO
Specs
Heater Type Tubular Heaters
Fuel / Energy Source Electric
Maximum Operating Temperature 1200 F (649 C)