Myron L Company pDS Meter EP11/PH

Description
Readings You Can Count On No water supply is completely pure. Every industrial, commercial, or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life. Myron L® Company has two proven ways to measure such impurities. Our DS Meters™ provide fast, accurate, on-the-spot measurements of total dissolved solids (TDS) or conductivity. pDS Meters™ test conductivity or TDS, plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications, some of which are listed above. Unique Field-Tested Design Our unique, durable, field-tested design has evolved over more than 40 years, making Myron L® instruments among the most reliable and popular of their kind in the world. They’re lightweight and compact, yet Myron L®’s DS and pDS Meters are also tough, with rugged, taut-band meter movements. Put our meters to the test. Even after years of rough field service, they’ll surpass your expectations of accuracy, reliability and simplicity.
Request a Quote
Description
Readings You Can Count On No water supply is completely pure. Every industrial, commercial, or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life. Myron L® Company has two proven ways to measure such impurities. Our DS Meters™ provide fast, accurate, on-the-spot measurements of total dissolved solids (TDS) or conductivity. pDS Meters™ test conductivity or TDS, plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications, some of which are listed above. Unique Field-Tested Design Our unique, durable, field-tested design has evolved over more than 40 years, making Myron L® instruments among the most reliable and popular of their kind in the world. They’re lightweight and compact, yet Myron L®’s DS and pDS Meters are also tough, with rugged, taut-band meter movements. Put our meters to the test. Even after years of rough field service, they’ll surpass your expectations of accuracy, reliability and simplicity.
Request a Quote
Datasheet
Datasheet Summary
Powered by GS/AI

The EP11/PH is a pDS Meter designed for measuring conductivity, TDS, and pH in water quality applications. It features a built-in conductivity cell with a chip- and crack-resistant polyethylene cup, a field-replaceable KCl gel-filled pH electrode with a porous liquid junction, and a 2.5-inch taut-band shock-resistant meter. It measures conductivity in ranges up to 10,000 ppm or µS and pH from 2 to 12, with automatic temperature compensation to 25°C. Accuracy is ±2% of full scale for conductivity and ±0.2 pH units. Power is supplied by a 9-volt battery with over 2000 tests per year life. Dimensions are 86 W × 114 D × 102 H mm, weighing 0.45 kg. It includes pH zero and gain controls and requires NIST-traceable calibration standards for maintenance.

Datasheet Summary
Powered by GS/AI

The EP11/PH is a pDS Meter designed for measuring conductivity, TDS, and pH in water quality applications. It features a built-in conductivity cell with a chip- and crack-resistant polyethylene cup, a field-replaceable KCl gel-filled pH electrode with a porous liquid junction, and a 2.5-inch taut-band shock-resistant meter. It measures conductivity in ranges up to 10,000 ppm or µS and pH from 2 to 12, with automatic temperature compensation to 25°C. Accuracy is ±2% of full scale for conductivity and ±0.2 pH units. Power is supplied by a 9-volt battery with over 2000 tests per year life. Dimensions are 86 W × 114 D × 102 H mm, weighing 0.45 kg. It includes pH zero and gain controls and requires NIST-traceable calibration standards for maintenance.

Suppliers

Company
Product
Description
Supplier Links
pDS Meter - EP11/PH - Myron L Company
Carlsbad, CA, USA
pDS Meter
EP11/PH
pDS Meter EP11/PH
Readings You Can Count On No water supply is completely pure. Every industrial, commercial, or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life. Myron L® Company has two proven ways to measure such impurities. Our DS Meters™ provide fast, accurate, on-the-spot measurements of total dissolved solids (TDS) or conductivity. pDS Meters™ test conductivity or TDS, plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications, some of which are listed above. Unique Field-Tested Design Our unique, durable, field-tested design has evolved over more than 40 years, making Myron L® instruments among the most reliable and popular of their kind in the world. They’re lightweight and compact, yet Myron L®’s DS and pDS Meters are also tough, with rugged, taut-band meter movements. Put our meters to the test. Even after years of rough field service, they’ll surpass your expectations of accuracy, reliability and simplicity.

Readings You Can Count On

No water supply is completely pure. Every industrial, commercial, or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life.

Myron L® Company has two proven ways to measure such impurities. Our DS Meters™ provide fast, accurate, on-the-spot measurements of total dissolved solids (TDS) or conductivity. pDS Meters™ test conductivity or TDS, plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications, some of which are listed above.

Unique Field-Tested Design

Our unique, durable, field-tested design has evolved over more than 40 years, making Myron L® instruments among the most reliable and popular of their kind in the world. They’re lightweight and compact, yet Myron L®’s DS and pDS Meters are also tough, with rugged, taut-band meter movements. Put our meters to the test. Even after years of rough field service, they’ll surpass your expectations of accuracy, reliability and simplicity.

Supplier's Site Datasheet

Technical Specifications

  Myron L Company
Product Category Conductivity Electrodes
Product Number EP11/PH
Product Name pDS Meter
Conductivity Range 0.0 to 10000 MicroSiemens/cm
Unlock Full Specs
to access all available technical data

Similar Products

Dialysate Meter DS Conductivity Meter - D-2 - Myron L Company
Specs
Electrode Accuracy 2 (+/- % FS)
Mounting Options Hand Held (Dip) or Portable
Maximum Diameter / Width 3.4 inch (86.36 mm)
View Details
DS Meter - 512M1 - Myron L Company
Myron L Company
Specs
Mounting Options Hand Held (Dip) or Portable
Maximum Diameter / Width 3.4 inch (86.36 mm)
Maximum Length 4 inch (102 mm)
View Details
750 II Conductivity/TDS Monitor/Controller - 758II - Myron L Company
Specs
Conductivity Range 0.0 to 200 MicroSiemens/cm
Electrode Accuracy 1 (+/- % FS)
Maximum Diameter / Width 4.8 inch (122 mm)
View Details
750 II Conductivity/TDS Monitor/Controller - 759II - Myron L Company
Specs
Conductivity Range 0.0 to 200 MicroSiemens/cm
Electrode Accuracy 1 (+/- % FS)
Maximum Diameter / Width 4.8 inch (122 mm)
View Details