MSA Safety Open Path Gas Detector Senscient ELDS™

Description
Senscient open path gas detector ensures best in class false alarm rejection. The Senscient ELDS laser-based open path gas detector is available for a wide range of toxic and flammable gases. The Senscient ELDS uses 'SimuGas' self-testing to eliminate employees entering hazardous areas for gas checks. Nuisance false alarms are virtually eliminated with its breakthrough Harmonic Fingerprint processing. Gases detected: hydrogen sulfide (H2S), sour gas (H2S/CH4), methane (CH4), ethylene (C2H4), ammonia (NH3), carbon dioxide (CO2), hydrogen chloride, (HCl), hydrogen fluoride (HF) Gas-specific Harmonic Fingerprint detection eliminates false alarms and prevents plant shutdowns SimuGas automated function checks are recorded daily and eliminate need for manual intervention Tuneable lasers scan more narrow portion of spectrum where water interference from weather conditions are minimized Bluetooth wireless technology and SITE software simplifies commissioning, diagnostics, and event log retrieval Senscient ELDS lasers are hard on fog, rain, and snow but are easy on the eyes with a Class 1 eye-safe designation. Fastest responding device for safety critical ventilation zone and cross duct applications No costly communication cable required between transmitter and receiver Significantly improves the safety, efficiency, and operational costs of your gas detection program FM 6325 performance approved for methane Markets: General Industry, Oil & Gas, Utilities
Request a Quote
Description
Senscient open path gas detector ensures best in class false alarm rejection. The Senscient ELDS laser-based open path gas detector is available for a wide range of toxic and flammable gases. The Senscient ELDS uses 'SimuGas' self-testing to eliminate employees entering hazardous areas for gas checks. Nuisance false alarms are virtually eliminated with its breakthrough Harmonic Fingerprint processing. Gases detected: hydrogen sulfide (H2S), sour gas (H2S/CH4), methane (CH4), ethylene (C2H4), ammonia (NH3), carbon dioxide (CO2), hydrogen chloride, (HCl), hydrogen fluoride (HF) Gas-specific Harmonic Fingerprint detection eliminates false alarms and prevents plant shutdowns SimuGas automated function checks are recorded daily and eliminate need for manual intervention Tuneable lasers scan more narrow portion of spectrum where water interference from weather conditions are minimized Bluetooth wireless technology and SITE software simplifies commissioning, diagnostics, and event log retrieval Senscient ELDS lasers are hard on fog, rain, and snow but are easy on the eyes with a Class 1 eye-safe designation. Fastest responding device for safety critical ventilation zone and cross duct applications No costly communication cable required between transmitter and receiver Significantly improves the safety, efficiency, and operational costs of your gas detection program FM 6325 performance approved for methane Markets: General Industry, Oil & Gas, Utilities
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Open Path Gas Detector - Senscient ELDS™ - MSA Safety
Cranberry Twp., PA, United States
Open Path Gas Detector
Senscient ELDS™
Open Path Gas Detector Senscient ELDS™
Senscient open path gas detector ensures best in class false alarm rejection. The Senscient ELDS laser-based open path gas detector is available for a wide range of toxic and flammable gases. The Senscient ELDS uses 'SimuGas' self-testing to eliminate employees entering hazardous areas for gas checks. Nuisance false alarms are virtually eliminated with its breakthrough Harmonic Fingerprint processing. Gases detected: hydrogen sulfide (H2S), sour gas (H2S/CH4), methane (CH4), ethylene (C2H4), ammonia (NH3), carbon dioxide (CO2), hydrogen chloride, (HCl), hydrogen fluoride (HF) Gas-specific Harmonic Fingerprint detection eliminates false alarms and prevents plant shutdowns SimuGas automated function checks are recorded daily and eliminate need for manual intervention Tuneable lasers scan more narrow portion of spectrum where water interference from weather conditions are minimized Bluetooth wireless technology and SITE software simplifies commissioning, diagnostics, and event log retrieval Senscient ELDS lasers are hard on fog, rain, and snow but are easy on the eyes with a Class 1 eye-safe designation. Fastest responding device for safety critical ventilation zone and cross duct applications No costly communication cable required between transmitter and receiver Significantly improves the safety, efficiency, and operational costs of your gas detection program FM 6325 performance approved for methane Markets: General Industry, Oil & Gas, Utilities

Senscient open path gas detector ensures best in class false alarm rejection. The Senscient ELDS laser-based open path gas detector is available for a wide range of toxic and flammable gases. The Senscient ELDS uses 'SimuGas' self-testing to eliminate employees entering hazardous areas for gas checks. Nuisance false alarms are virtually eliminated with its breakthrough Harmonic Fingerprint processing.

  • Gases detected: hydrogen sulfide (H2S), sour gas (H2S/CH4), methane (CH4), ethylene (C2H4), ammonia (NH3), carbon dioxide (CO2), hydrogen chloride, (HCl), hydrogen fluoride (HF)
  • Gas-specific Harmonic Fingerprint detection eliminates false alarms and prevents plant shutdowns
  • SimuGas automated function checks are recorded daily and eliminate need for manual intervention
  • Tuneable lasers scan more narrow portion of spectrum where water interference from weather conditions are minimized
  • Bluetooth wireless technology and SITE software simplifies commissioning, diagnostics, and event log retrieval
  • Senscient ELDS lasers are hard on fog, rain, and snow but are easy on the eyes with a Class 1 eye-safe designation.
  • Fastest responding device for safety critical ventilation zone and cross duct applications
  • No costly communication cable required between transmitter and receiver
  • Significantly improves the safety, efficiency, and operational costs of your gas detection program
  • FM 6325 performance approved for methane

Markets: General Industry, Oil & Gas, Utilities

Supplier's Site

Technical Specifications

  MSA Safety
Product Category Gas Instruments
Product Number Senscient ELDS™
Product Name Open Path Gas Detector
Measurement Type %Volume
Application Ambient Air Monitoring
Gas Types Toxic; NH3; CO2; HCl; HF; H2S; Methane (CH4) / Natural Gas
Electrical Outputs Current
Instrument Type Detector; Monitor
Unlock Full Specs
to access all available technical data

Similar Products

Controller Unit - 9010/9020 - MSA Safety
Specs
Measurement Type %LEL or %LFL; Trace
Application Ambient Air Monitoring
Gas Types Toxic; Combustible
View Details
Wearable Gas Detector - ALTAIRio™4 - MSA Safety
Specs
Application Process Gas
Display Digital
Instrument Type Detector
View Details
Photoacoustic Infrared Gas Monitor - Chemgard® - MSA Safety
Specs
Measurement Type %LEL or %LFL; %Volume; Trace
Application Ambient Air Monitoring
Gas Types Toxic; CO2; CO; Hydrocarbons
View Details
HVAC Gas Monitor - Z-Gard® DS MPO Dual Gas Sensor - MSA Safety
Specs
Measurement Type Trace
Application Ambient Air Monitoring
Gas Types Toxic; CO; (0-100 ppm, 0-200 ppm); NO2; (0-10 ppm)
View Details