HVACQuick.com Greystone Low Pressure Transducer LP2A05

Description
Greystone - Low differential pressure transducer - jumper selectable. No LCD. +/-100, +/-200, 0-200, 0-400 Pa The LP2 Low Pressure Transducer can be used to measure positive, negative or differential pressure in the ranges of 1.00" W.C. to 12" W.C. (200 to 2000 Pa). • Jumper selectable 2 wire current and 3 wire voltage outputs standard • 24 Vac/dc power supply standard • Four variable jumper selectable pressure ranges, W.C. and Pa. • Functional weather resistant ABS Enclosure • Available options include LCD display and integrated static probe
Description
Greystone - Low differential pressure transducer - jumper selectable. No LCD. +/-100, +/-200, 0-200, 0-400 Pa The LP2 Low Pressure Transducer can be used to measure positive, negative or differential pressure in the ranges of 1.00" W.C. to 12" W.C. (200 to 2000 Pa). • Jumper selectable 2 wire current and 3 wire voltage outputs standard • 24 Vac/dc power supply standard • Four variable jumper selectable pressure ranges, W.C. and Pa. • Functional weather resistant ABS Enclosure • Available options include LCD display and integrated static probe

Suppliers

Company
Product
Description
Supplier Links
Greystone Low Pressure Transducer - LP2A05 - HVACQuick.com
Medford, OR, USA
Greystone Low Pressure Transducer
LP2A05
Greystone Low Pressure Transducer LP2A05
Greystone - Low differential pressure transducer - jumper selectable. No LCD. +/-100, +/-200, 0-200, 0-400 Pa The LP2 Low Pressure Transducer can be used to measure positive, negative or differential pressure in the ranges of 1.00" W.C. to 12" W.C. (200 to 2000 Pa). • Jumper selectable 2 wire current and 3 wire voltage outputs standard • 24 Vac/dc power supply standard • Four variable jumper selectable pressure ranges, W.C. and Pa. • Functional weather resistant ABS Enclosure • Available options include LCD display and integrated static probe

Greystone - Low differential pressure transducer - jumper selectable. No LCD. +/-100, +/-200, 0-200, 0-400 Pa

The LP2 Low Pressure Transducer can be used to measure positive, negative or differential pressure in the ranges of 1.00" W.C. to 12" W.C. (200 to 2000 Pa).

• Jumper selectable 2 wire current and 3 wire voltage outputs standard
• 24 Vac/dc power supply standard
• Four variable jumper selectable pressure ranges, W.C. and Pa.
• Functional weather resistant ABS Enclosure
• Available options include LCD display and integrated static probe

Supplier's Site

Technical Specifications

  HVACQuick.com
Product Category Pressure Sensors
Product Number LP2A05
Product Name Greystone Low Pressure Transducer
Device Category Sensor (optional feature)
Unlock Full Specs
to access all available technical data

Similar Products

Pressure Transducer -  - HydraCheck Inc.
HydraCheck Inc.
Specs
Device Category Sensor or Transducer
Measurement Type Differential
Operating Temperature -4 to 185 F (-20 to 85 C)
View Details
Model Z Wet/Wet Differential Pressure Transducer - SPT-Z-D - RDP Electrosense
Specs
Device Category Sensor or Transducer
Measurement Type Differential
Signal Output Analog Voltage; 2mV/V
View Details
Sensor technology - Pressure sensors - Barometric (BAP) & Manifold (MAP) sensors - KP229E3111 -  - Infineon Technologies AG
Specs
Device Category Sensor
Measurement Type Gauge
View Details
Standard Solid-State Pressure Sensor - 836P-D2GBGB30PA-D4 - Allen-Bradley / Rockwell Automation
Specs
Device Category Sensor
Measurement Type Gauge
Signal Output Analog Current
View Details