Description
Fantech Lint Trap Replacement Screen for DBLT 4 Traps. Dryer boosting kits and lint traps. Typical residential dryers are rated at 160 cfm. However, boosting is generally needed in order to maintain a minimum airflow of 100cfm as duct length increases and bends are introduced in the duct line. Fantech models DBF 110, DBF 4XL, DBF 4XLT and RVF 4XL-DB10 are all suitable for most dryer boosting applications. Generally the models listed can be used for maximum duct length of 60 linear feet with a maximum of six elbows using four inch rigid duct. The booster switch monitors dryer operation and will activate the fan when the dryer comes on. Preset to cycle in ten minute intervals the fan will stay on until the dryer stops.
Description
Fantech Lint Trap Replacement Screen for DBLT 4 Traps. Dryer boosting kits and lint traps. Typical residential dryers are rated at 160 cfm. However, boosting is generally needed in order to maintain a minimum airflow of 100cfm as duct length increases and bends are introduced in the duct line. Fantech models DBF 110, DBF 4XL, DBF 4XLT and RVF 4XL-DB10 are all suitable for most dryer boosting applications. Generally the models listed can be used for maximum duct length of 60 linear feet with a maximum of six elbows using four inch rigid duct. The booster switch monitors dryer operation and will activate the fan when the dryer comes on. Preset to cycle in ten minute intervals the fan will stay on until the dryer stops.

Suppliers

Company
Product
Description
Supplier Links
Fantech Dryer Booster Fans - 12304 - HVACQuick.com
Medford, OR, USA
Fantech Dryer Booster Fans
12304
Fantech Dryer Booster Fans 12304
Fantech Lint Trap Replacement Screen for DBLT 4 Traps. Dryer boosting kits and lint traps. Typical residential dryers are rated at 160 cfm. However, boosting is generally needed in order to maintain a minimum airflow of 100cfm as duct length increases and bends are introduced in the duct line. Fantech models DBF 110, DBF 4XL, DBF 4XLT and RVF 4XL-DB10 are all suitable for most dryer boosting applications. Generally the models listed can be used for maximum duct length of 60 linear feet with a maximum of six elbows using four inch rigid duct. The booster switch monitors dryer operation and will activate the fan when the dryer comes on. Preset to cycle in ten minute intervals the fan will stay on until the dryer stops.

Fantech Lint Trap Replacement Screen for DBLT 4 Traps.

Dryer boosting kits and lint traps. Typical residential dryers are rated at 160 cfm. However, boosting is generally needed in order to maintain a minimum airflow of 100cfm as duct length increases and bends are introduced in the duct line. Fantech models DBF 110, DBF 4XL, DBF 4XLT and RVF 4XL-DB10 are all suitable for most dryer boosting applications. Generally the models listed can be used for maximum duct length of 60 linear feet with a maximum of six elbows using four inch rigid duct.

The booster switch monitors dryer operation and will activate the fan when the dryer comes on. Preset to cycle in ten minute intervals the fan will stay on until the dryer stops.

Supplier's Site

Technical Specifications

  HVACQuick.com
Product Category Fans and Blowers (industrial)
Product Number 12304
Product Name Fantech Dryer Booster Fans
Unlock Full Specs
to access all available technical data

Similar Products

Turbo Blowers - FDC-020A-7W - Fuji Electric Corp. of America
Fuji Electric Corp. of America
Specs
Applications / Use Pressure Blower; Product / Process Cooling; Ventilation; Materials Handling
Product Form Packaged
Environment Clean
View Details
Mini Blower PTA12060-A - PTA12060HH12B-A - Pelonis Technologies, Inc.
Specs
Product Form Packaged
Environment Clean
Drive Type Direct
View Details
Explosion-Proof Exhaust Fan - EFX - Thermon, Inc
Specs
Applications / Use Ventilation
Product Form Packaged
Draft Forced Draft
View Details
Filter Fans - 7336189 - RS Components, Ltd.
RS Components, Ltd.
Specs
Configuration Filter Fans
Air Flow Rate 176 SCFM (300 m³/hr)
View Details