Point level switch for multiple point detection in conductive liquids
Your benefits
Detect up to five level limits with one probe
Two-point control and additional maximum and minimum detection
Flexible instrumentation: - with built-in electronic insert, either transistor or relay output for 2 or 3 rope (or rod) probes - for connection to a separate transmitter power supply unit
No calibration required; standard setting for the most common conductive liquids
No moving parts in the tank: - long service life - reliable operation with no wear or blockages
WHG approval
Four measuring ranges can be set 100 ω, 1 kω, 10 kω, 100 kω
Cost-effective probe for conductive liquids
Electronic inserts for: - NAMUR output - Relais output - Transistor output
Point level switch for multiple point detection in conductive liquids
Your benefits
- Detect up to five level limits with one probe
- Two-point control and additional maximum and minimum detection
- Flexible instrumentation:
- with built-in electronic insert, either transistor or relay output for 2 or 3 rope (or rod) probes
- for connection to a separate transmitter power supply unit
- No calibration required; standard setting for the most common conductive liquids
- No moving parts in the tank:
- long service life
- reliable operation with no wear or blockages
- WHG approval
- Four measuring ranges can be set 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
- Cost-effective probe for conductive liquids
- Electronic inserts for:
- NAMUR output
- Relais output
- Transistor output