Emerson Automation Solutions – Rosemount X-STREAM™ Process Gas Analyzer General Purpose Configuration (X2GP)

Description
The X-STREAM process gas analyzer delivers the analytical tools necessary for precise, accurate gas analysis in a wide variety of applications and environments. Its comprehensive package sets X-STREAM apart from other analyzers by offering multi-component analysis using infrared, ultraviolet and visible (NDIR/UV/VIS) photometry, paramagnetic and electrochemical oxygen, and thermal conductivity sensor technologies for consistent, precise process gas measurement. X-STREAM analyzers measure up to four components in various combinations, and its versatile design allows physical benches to be installed in their own compartment, separate from the electronics. General Purpose Configuration (X2GP) A rack-mountable analyzer features a separate purge for the physics and electronics.
Datasheet
Description
The X-STREAM process gas analyzer delivers the analytical tools necessary for precise, accurate gas analysis in a wide variety of applications and environments. Its comprehensive package sets X-STREAM apart from other analyzers by offering multi-component analysis using infrared, ultraviolet and visible (NDIR/UV/VIS) photometry, paramagnetic and electrochemical oxygen, and thermal conductivity sensor technologies for consistent, precise process gas measurement. X-STREAM analyzers measure up to four components in various combinations, and its versatile design allows physical benches to be installed in their own compartment, separate from the electronics. General Purpose Configuration (X2GP) A rack-mountable analyzer features a separate purge for the physics and electronics.
Datasheet

Suppliers

Company
Product
Description
Supplier Links
X-STREAM™ Process Gas Analyzer General Purpose Configuration (X2GP)
The X-STREAM process gas analyzer delivers the analytical tools necessary for precise, accurate gas analysis in a wide variety of applications and environments. Its comprehensive package sets X-STREAM apart from other analyzers by offering multi-component analysis using infrared, ultraviolet and visible (NDIR/UV/VIS) photometry, paramagnetic and electrochemical oxygen, and thermal conductivity sensor technologies for consistent, precise process gas measurement. X-STREAM analyzers measure up to four components in various combinations, and its versatile design allows physical benches to be installed in their own compartment, separate from the electronics. General Purpose Configuration (X2GP) A rack-mountable analyzer features a separate purge for the physics and electronics.

The X-STREAM process gas analyzer delivers the analytical tools necessary for precise, accurate gas analysis in a wide variety of applications and environments. Its comprehensive package sets X-STREAM apart from other analyzers by offering multi-component analysis using infrared, ultraviolet and visible (NDIR/UV/VIS) photometry, paramagnetic and electrochemical oxygen, and thermal conductivity sensor technologies for consistent, precise process gas measurement.

X-STREAM analyzers measure up to four components in various combinations, and its versatile design allows physical benches to be installed in their own compartment, separate from the electronics.

General Purpose Configuration (X2GP)
A rack-mountable analyzer features a separate purge for the physics and electronics.

Supplier's Site Datasheet

Technical Specifications

  Emerson Automation Solutions – Rosemount
Product Category Gas Instruments
Product Number General Purpose Configuration (X2GP)
Product Name X-STREAM™ Process Gas Analyzer
Measurement Type %Volume; Trace
Application Process Gas
Gas Types Toxic; NH3; (0-100 ppm, 0-100%); CO2; (0-50 ppm, 0-100%); CO; (0-50 ppm, 0-100%); Cl2; (0-300 ppm, 0-100&); Hydrocarbons; H2; (0-100%); H2S; (0-100%); Methane (CH4) / Natural Gas; (0-100 ppm, 0-100%); NxOx; (0-250 ppm, 0-100%); O2; (0-100%); SO2; (0-130 ppm, 0-100%); SF6; (0-20 ppm, 0-2%); Water Vapor; (0-3000 ppm, 0-8%)
Electrical Outputs Current
Display Digital
Unlock Full Specs
to access all available technical data

Similar Products

Vapor Flammability Analyzer - PrevEx Model SNR702 - Control Instruments Corp.
Specs
Measurement Type %LEL or %LFL
Application Ambient Air Monitoring; Process Gas
Gas Types Combustible; Hydrocarbons; (0-100% LFL); H2; (0-100% LFL); Methane (CH4) / Natural Gas; (0-100% LFL)
View Details
Fire and Gas System - SUPREMATouch - MSA Safety
Specs
Application Process Gas
Electrical Outputs Current
Display Digital
View Details
Oxygen Combustible Fixed Gas Detector (0-25%) -  - CO2Meter.com
Specs
Gas Types Combustible; O2; (Combustible Fixed Gas Detectors - Oxygen Combustible Fixed Gas Detector (0-25%))
Number of Gases Monitored Single
Operating Temperature -30 to 122 F (-34 to 50 C)
View Details
Infrared Gas Analyzer High Performance Model - ZPB Series - Fuji Electric Corp. of America
Specs
Application Process Gas
Gas Types CO2; (0-50ppm); CO; (0-5000); NO; (0-5000ppm); SO2; (0-5000ppm)
Electrical Outputs Current
View Details