Ecologix Environmental Systems Maxiline MBF HD F3AV18000012

Description
The Maxiline VMBF SE design prevents the cover from being opened until the vessel has been properly vented. A threaded spindle mechanism, operated by a hand wheel, opens the clamp so that the cover can be raised with the help of a spring assisted hinge. The entire process takes less than 30 seconds compared to the 10 MINUTES or more it takes to open a vessel with bolted closure. The vessel cannot be re-pressurized until the Qic-Lock clamp has been fully closed and the safety interlock engaged which closes the vent valve.
Description
The Maxiline VMBF SE design prevents the cover from being opened until the vessel has been properly vented. A threaded spindle mechanism, operated by a hand wheel, opens the clamp so that the cover can be raised with the help of a spring assisted hinge. The entire process takes less than 30 seconds compared to the 10 MINUTES or more it takes to open a vessel with bolted closure. The vessel cannot be re-pressurized until the Qic-Lock clamp has been fully closed and the safety interlock engaged which closes the vent valve.

Suppliers

Company
Product
Description
Supplier Links
Maxiline MBF HD - F3AV18000012 - Ecologix Environmental Systems
Alpharetta, GA, USA
Maxiline MBF HD
F3AV18000012
Maxiline MBF HD F3AV18000012
The Maxiline VMBF SE design prevents the cover from being opened until the vessel has been properly vented. A threaded spindle mechanism, operated by a hand wheel, opens the clamp so that the cover can be raised with the help of a spring assisted hinge. The entire process takes less than 30 seconds compared to the 10 MINUTES or more it takes to open a vessel with bolted closure. The vessel cannot be re-pressurized until the Qic-Lock clamp has been fully closed and the safety interlock engaged which closes the vent valve.

The Maxiline VMBF SE design prevents the cover from being opened until the vessel has been properly vented. A threaded spindle mechanism, operated by a hand wheel, opens the clamp so that the cover can be raised with the help of a spring assisted hinge. The entire process takes less than 30 seconds compared to the 10 MINUTES or more it takes to open a vessel with bolted closure. The vessel cannot be re-pressurized until the Qic-Lock clamp has been fully closed and the safety interlock engaged which closes the vent valve.

Supplier's Site

Technical Specifications

  Ecologix Environmental Systems
Product Category Scrubbers
Product Number F3AV18000012
Product Name Maxiline MBF HD
Process Type Dry Type
Unlock Full Specs
to access all available technical data

Similar Products

Dry FGD (Dry Sorbent Injection) -  - Ducon Environmental Systems 
Ducon Environmental Systems 
Specs
Pollutants Scrubbed Other Pollents; Sulfur dioxide, hydrogen chloride, and other toxic components
Process Type Dry Type
View Details
Integrated Scrubber Tail Gas Treatment Cabinet for Safe Bulk Specialty Gas System Exhaust Management -  - Shenzhen Jewellok Technology Co., Ltd.
Specs
Pollutants Scrubbed Other Pollents; Hazardous byproducts such as SiH4, NH3, and HCL
Scrubber Type Skid / Base Plate Mounted
Orientation Vertical
View Details
HE Venturi Scrubbers -  - Branch Environmental Solutions
Branch Environmental Solutions
Specs
Pollutants Scrubbed Caustic
Process Type Wet Type
Filter Type Wet Scrubber
View Details
Fume Hood with Wet Fume Scrubber - AirMax™ AC4030TE - AirClean Systems
Specs
Pollutants Scrubbed Chlorine Gas; Ammonia; Acid; Caustic
Orientation Vertical
Process Type Wet Type
View Details