Conax Technologies RTD / Thermocouple Assembly for Hazardous Locations CT 600

Description
CT 600 Series sensor-terminal head assemblies are available in all thermocouple calibrations and in RTD assemblies with 100, 200, 500 and 1000 ohm platinum, 10 ohm copper or 120 ohm nickel elements. Assemblies are available with stainless steel or Inconel sheaths, a spring loaded mounting fitting (CSLW) and explosion-proof terminal head with terminal strip. Note: Sensor must be installed into either a thermowell or a port machined into a solid metal piece with a 1/2′-14 NPT mounting connection made per ANSI/ASME B1.20.1 and gauged to +1/2 to +2 turns from flush with end of start thread in accordance with CSA Std. C22.2 0.5 and UL Std. 1203, A 36′ maximum bore depth, a 0.104′ minimum wall, and a ∅0.302′ maximum bore.
Request a Quote
Description
CT 600 Series sensor-terminal head assemblies are available in all thermocouple calibrations and in RTD assemblies with 100, 200, 500 and 1000 ohm platinum, 10 ohm copper or 120 ohm nickel elements. Assemblies are available with stainless steel or Inconel sheaths, a spring loaded mounting fitting (CSLW) and explosion-proof terminal head with terminal strip. Note: Sensor must be installed into either a thermowell or a port machined into a solid metal piece with a 1/2′-14 NPT mounting connection made per ANSI/ASME B1.20.1 and gauged to +1/2 to +2 turns from flush with end of start thread in accordance with CSA Std. C22.2 0.5 and UL Std. 1203, A 36′ maximum bore depth, a 0.104′ minimum wall, and a ∅0.302′ maximum bore.
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
RTD / Thermocouple Assembly for Hazardous Locations - CT 600 - Conax Technologies
Buffalo, NY, United States
RTD / Thermocouple Assembly for Hazardous Locations
CT 600
RTD / Thermocouple Assembly for Hazardous Locations CT 600
CT 600 Series sensor-terminal head assemblies are available in all thermocouple calibrations and in RTD assemblies with 100, 200, 500 and 1000 ohm platinum, 10 ohm copper or 120 ohm nickel elements. Assemblies are available with stainless steel or Inconel sheaths, a spring loaded mounting fitting (CSLW) and explosion-proof terminal head with terminal strip. Note: Sensor must be installed into either a thermowell or a port machined into a solid metal piece with a 1/2′-14 NPT mounting connection made per ANSI/ASME B1.20.1 and gauged to +1/2 to +2 turns from flush with end of start thread in accordance with CSA Std. C22.2 0.5 and UL Std. 1203, A 36′ maximum bore depth, a 0.104′ minimum wall, and a ∅0.302′ maximum bore.

CT 600 Series sensor-terminal head assemblies are available in all thermocouple calibrations and in RTD assemblies with 100, 200, 500 and 1000 ohm platinum, 10 ohm copper or 120 ohm nickel elements. Assemblies are available with stainless steel or Inconel sheaths, a spring loaded mounting fitting (CSLW) and explosion-proof terminal head with terminal strip. Note: Sensor must be installed into either a thermowell or a port machined into a solid metal piece with a 1/2″-14 NPT mounting connection made per ANSI/ASME B1.20.1 and gauged to +1/2 to +2 turns from flush with end of start thread in accordance with CSA Std. C22.2 0.5 and UL Std. 1203, A 36″ maximum bore depth, a 0.104″ minimum wall, and a ∅0.302″ maximum bore.

Supplier's Site

Technical Specifications

  Conax Technologies
Product Category RTD Temperature Probes
Product Number CT 600
Product Name RTD / Thermocouple Assembly for Hazardous Locations
Element Material Platinum
Unlock Full Specs
to access all available technical data