BlueSens Gas Sensor GmbH Online Gas Analyzer BlueInOne Ferm

Description
The new online gas analyzer for bioprocesses combines the parallel measurement of CO2 and O2 with just one space-saving sensor. It can be used for fermenters of every size, from the lab to industrial scale. The BlueInOne Ferm also measures the pressure and humidity in the off gas of the bioprocess. Therefore the BlueInOne Ferm gas analyzer is neither affected by the gas flow nor by humidity in the process. This state-of-the-art combined gas analyzer stands for highest precision and reliability. Advantages: parallel measurement of O2 and CO2 Modbus OPC server available compact stainless steel housing QbD conform in-situ-measurement auto compensated humidity and pressure no gas cooler, pumps or valves needed connectable to any hose/tube or pipe status display by luminous pushbuttons Application areas: online fermentation monitoring real time process optimization from lab to industrial scale Concentration ranges: 1. CO2: 0 - 10 Vol.%, O2: 0.1 - 25 Vol.% 2. CO2: 0 - 25 Vol.%, O2: 0.1 - 25 Vol.% 3. CO2: 0 - 10 Vol.%, O2: 1 - 50 Vol.% 4. CO2: 0 - 25 Vol.%, O2: 1 - 50 Vol.% Measuring principle: IR(CO2), ZrO2 (O2) Temperature inside of the sensor unit: 580°C/1076°F (O2 sensor unit)
Description
The new online gas analyzer for bioprocesses combines the parallel measurement of CO2 and O2 with just one space-saving sensor. It can be used for fermenters of every size, from the lab to industrial scale. The BlueInOne Ferm also measures the pressure and humidity in the off gas of the bioprocess. Therefore the BlueInOne Ferm gas analyzer is neither affected by the gas flow nor by humidity in the process. This state-of-the-art combined gas analyzer stands for highest precision and reliability. Advantages: parallel measurement of O2 and CO2 Modbus OPC server available compact stainless steel housing QbD conform in-situ-measurement auto compensated humidity and pressure no gas cooler, pumps or valves needed connectable to any hose/tube or pipe status display by luminous pushbuttons Application areas: online fermentation monitoring real time process optimization from lab to industrial scale Concentration ranges: 1. CO2: 0 - 10 Vol.%, O2: 0.1 - 25 Vol.% 2. CO2: 0 - 25 Vol.%, O2: 0.1 - 25 Vol.% 3. CO2: 0 - 10 Vol.%, O2: 1 - 50 Vol.% 4. CO2: 0 - 25 Vol.%, O2: 1 - 50 Vol.% Measuring principle: IR(CO2), ZrO2 (O2) Temperature inside of the sensor unit: 580°C/1076°F (O2 sensor unit)

Suppliers

Company
Product
Description
Supplier Links
Online Gas Analyzer - BlueInOne Ferm - BlueSens Gas Sensor GmbH
Herten, Germany
Online Gas Analyzer
BlueInOne Ferm
Online Gas Analyzer BlueInOne Ferm
The new online gas analyzer for bioprocesses combines the parallel measurement of CO2 and O2 with just one space-saving sensor. It can be used for fermenters of every size, from the lab to industrial scale. The BlueInOne Ferm also measures the pressure and humidity in the off gas of the bioprocess. Therefore the BlueInOne Ferm gas analyzer is neither affected by the gas flow nor by humidity in the process. This state-of-the-art combined gas analyzer stands for highest precision and reliability. Advantages: parallel measurement of O2 and CO2 Modbus OPC server available compact stainless steel housing QbD conform in-situ-measurement auto compensated humidity and pressure no gas cooler, pumps or valves needed connectable to any hose/tube or pipe status display by luminous pushbuttons Application areas: online fermentation monitoring real time process optimization from lab to industrial scale Concentration ranges: 1. CO2: 0 - 10 Vol.%, O2: 0.1 - 25 Vol.% 2. CO2: 0 - 25 Vol.%, O2: 0.1 - 25 Vol.% 3. CO2: 0 - 10 Vol.%, O2: 1 - 50 Vol.% 4. CO2: 0 - 25 Vol.%, O2: 1 - 50 Vol.% Measuring principle: IR(CO2), ZrO2 (O2) Temperature inside of the sensor unit: 580°C/1076°F (O2 sensor unit)

The new online gas analyzer for bioprocesses combines the parallel measurement of CO2 and O2 with just one space-saving sensor. It can be used for fermenters of every size, from the lab to industrial scale. The BlueInOne Ferm also measures the pressure and humidity in the off gas of the bioprocess. Therefore the BlueInOne Ferm gas analyzer is neither affected by the gas flow nor by humidity in the process. This state-of-the-art combined gas analyzer stands for highest precision and reliability.

Advantages:

  • parallel measurement of O2 and CO2
  • Modbus OPC server available
  • compact stainless steel housing
  • QbD conform in-situ-measurement
  • auto compensated humidity and pressure
  • no gas cooler, pumps or valves needed
  • connectable to any hose/tube or pipe
  • status display by luminous pushbuttons

Application areas:

  • online fermentation monitoring
  • real time process optimization
  • from lab to industrial scale

Concentration ranges:

1. CO2: 0 - 10 Vol.%, O2: 0.1 - 25 Vol.%

2. CO2: 0 - 25 Vol.%, O2: 0.1 - 25 Vol.%

3. CO2: 0 - 10 Vol.%, O2: 1 - 50 Vol.%

4. CO2: 0 - 25 Vol.%, O2: 1 - 50 Vol.%

Measuring principle:

IR(CO2), ZrO2 (O2)

Temperature inside of the sensor unit:

580°C/1076°F (O2 sensor unit)

Supplier's Site

Technical Specifications

  BlueSens Gas Sensor GmbH
Product Category Gas Sensors
Product Number BlueInOne Ferm
Product Name Online Gas Analyzer
Unlock Full Specs
to access all available technical data

Similar Products

Sensor Stocker for PS-7/PS-8 Sensors (Holds 9) -  - DOD Technologies Inc.
Specs
Sensor Technology Electrochemical; Electrochemical
View Details
Senseair S8 Low Power CO2 Sensor -  - CO2Meter.com
Specs
Gas Types CO2; (Senseair S8 Low Power CO2 Sensor)
Number of Gases Monitored Single
View Details
Mini Oxygen Sensor Dual Hose Connection - SO-E61-XXX-DXXXC - Sensore Electronic GmbH
Specs
Sensor Technology zirconium dioxide (ZrO₂) technology
Gas Types O2; (100 ppm – 96 % O₂)
Electrical Outputs Current
View Details
Wireless Toxic Gas Sensor/Transmitter - Wireless GasPost, ACME-WS Series - Acme Engineering Products
Specs
Sensor Technology Catalytic (optional feature); Electrochemical (optional feature)
Measurement Type %LEL or %LFL; Trace
Gas Types Toxic; Combustible; NH3; (0-100 PPM); CO; (0-200 PPM); Hydrocarbons; (0-40% LEL); H2; (0-1000 PPM); H2S; (0-200 PPM); NO2; (0-10 PPM); O2; (0-25%)
View Details