Sichuan Odot Automation System Co., Ltd. Codesys PLC Modbus TCP Controller B2341

Description
The B2341 programming environment is Codesys, a programmable controller that follows the IEC61131-3 international standard, and supports five programming languages: ladder diagram (LD), instruction list (IL), structured text (ST), function block diagram (CFC), and sequential function diagram (SFC). The maximum number of expansion modules is 4, the user program storage supports 1 Mbytes, the power-down protection zone is 4 Kbytes, and Modbus TCP client and server are supported. It has rich instructions, reliable functions, good adaptability, compact structure, easy to expand, cost-effective, strong versatility, programming, monitoring, debugging, and on-site operation are very convenient, and the Ethernet interface on the CPU supports Modbus TCP client function, and supports access to the data of the third-party Modbus TCP server. Supports Modbus TCP server function and supports third-party Modbus TCP clients to access data. Supported I/O expansion modules include: A. Digital input module B. Digital output module C. Analog input module D. Analog output module E. Special function module
Request a Quote Datasheet
Description
The B2341 programming environment is Codesys, a programmable controller that follows the IEC61131-3 international standard, and supports five programming languages: ladder diagram (LD), instruction list (IL), structured text (ST), function block diagram (CFC), and sequential function diagram (SFC). The maximum number of expansion modules is 4, the user program storage supports 1 Mbytes, the power-down protection zone is 4 Kbytes, and Modbus TCP client and server are supported. It has rich instructions, reliable functions, good adaptability, compact structure, easy to expand, cost-effective, strong versatility, programming, monitoring, debugging, and on-site operation are very convenient, and the Ethernet interface on the CPU supports Modbus TCP client function, and supports access to the data of the third-party Modbus TCP server. Supports Modbus TCP server function and supports third-party Modbus TCP clients to access data. Supported I/O expansion modules include: A. Digital input module B. Digital output module C. Analog input module D. Analog output module E. Special function module
Request a Quote Datasheet

Suppliers

Company
Product
Description
Supplier Links
Codesys PLC Modbus TCP Controller - B2341 - Sichuan Odot Automation System Co., Ltd.
MianYang City, China
Codesys PLC Modbus TCP Controller
B2341
Codesys PLC Modbus TCP Controller B2341
The B2341 programming environment is Codesys, a programmable controller that follows the IEC61131-3 international standard, and supports five programming languages: ladder diagram (LD), instruction list (IL), structured text (ST), function block diagram (CFC), and sequential function diagram (SFC). The maximum number of expansion modules is 4, the user program storage supports 1 Mbytes, the power-down protection zone is 4 Kbytes, and Modbus TCP client and server are supported. It has rich instructions, reliable functions, good adaptability, compact structure, easy to expand, cost-effective, strong versatility, programming, monitoring, debugging, and on-site operation are very convenient, and the Ethernet interface on the CPU supports Modbus TCP client function, and supports access to the data of the third-party Modbus TCP server. Supports Modbus TCP server function and supports third-party Modbus TCP clients to access data. Supported I/O expansion modules include: A. Digital input module B. Digital output module C. Analog input module D. Analog output module E. Special function module

The B2341 programming environment is Codesys, a programmable controller that
follows the IEC61131-3 international standard, and supports five programming
languages: ladder diagram (LD), instruction list (IL), structured text (ST), function
block diagram (CFC), and sequential function diagram (SFC).

The maximum number of expansion modules is 4, the user program storage supports 1 Mbytes,
the power-down protection zone is 4 Kbytes, and Modbus TCP client and server are supported.

It has rich instructions, reliable functions, good adaptability, compact structure, easy
to expand, cost-effective, strong versatility, programming, monitoring, debugging, and
on-site operation are very convenient, and the Ethernet interface on the CPU supports
Modbus TCP client function, and supports access to the data of the third-party
Modbus TCP server.

Supports Modbus TCP server function and supports third-party Modbus TCP clients to access data.

Supported I/O expansion modules include:
A. Digital input module
B. Digital output module
C. Analog input module
D. Analog output module
E. Special function module

Supplier's Site Datasheet

Technical Specifications

  Sichuan Odot Automation System Co., Ltd.
Product Category Programmable Logic Controllers (PLC)
Product Number B2341
Product Name Codesys PLC Modbus TCP Controller
Computer Interface Options 2*RJ45
Unlock Full Specs
to access all available technical data

Similar Products

PLC Controller Modbus-TCP Modbus-RTU Codesysv3.5 - C3351 - Sichuan Odot Automation System Co., Ltd.
Sichuan Odot Automation System Co., Ltd.
Specs
Computer Interface Options 2 * RJ45 & 1 * RS485
Program Languages IEC61131-3; IEC 61131-3 (LD, IL, ST, CFC/FBD, SFC)
Maximum Channels 10
View Details
ODOT DU03L Web-Server Open PLC Profinet Master EtherCAT Master CANopen Master Controller - DU03L - Sichuan Odot Automation System Co., Ltd.
Specs
Network Options Ethernet
Program Languages IEC61131-3; IEC61499
Mounting Options DIN Rail
View Details
Codesys PLC Controller EtherCAT and CANOpen Protocol RTC - C4374 - Sichuan Odot Automation System Co., Ltd.
Specs
Computer Interface Options Single Serial Interface; 3*RJ45,1*RS485,1*CAN
Baud Rate 115200 bps
Network Options CANbus
View Details