Newport MKS Device Alignment Stage, Four-Axis, 3 mm Linear, 8° Angular, 8-32 & 1/4-20 9071

Description
The 9071 Four-Axis Tilt Aligner allows you to intuitively align optical tubes that comprise an input and an output (e. g., electro-optic or acousto-optic modulators or lenses). Center one end to the laser beam, then adjust the other until the beam emerges. All motions are independent and connected to a single base, so you won't induce coupled motion while making adjustments. These stages are great for aligning New Focus® modulators. 8-32 and 1/4-20 Threads. Patent Number 5,303,035
Request a Quote
Description
The 9071 Four-Axis Tilt Aligner allows you to intuitively align optical tubes that comprise an input and an output (e. g., electro-optic or acousto-optic modulators or lenses). Center one end to the laser beam, then adjust the other until the beam emerges. All motions are independent and connected to a single base, so you won't induce coupled motion while making adjustments. These stages are great for aligning New Focus® modulators. 8-32 and 1/4-20 Threads. Patent Number 5,303,035
Request a Quote

Suppliers

Company
Product
Description
Supplier Links
Device Alignment Stage, Four-Axis, 3 mm Linear, 8° Angular, 8-32 & 1/4-20 - 9071 - Newport MKS
Irvine, CA, United States
Device Alignment Stage, Four-Axis, 3 mm Linear, 8° Angular, 8-32 & 1/4-20
9071
Device Alignment Stage, Four-Axis, 3 mm Linear, 8° Angular, 8-32 & 1/4-20 9071
The 9071 Four-Axis Tilt Aligner allows you to intuitively align optical tubes that comprise an input and an output (e. g., electro-optic or acousto-optic modulators or lenses). Center one end to the laser beam, then adjust the other until the beam emerges. All motions are independent and connected to a single base, so you won't induce coupled motion while making adjustments. These stages are great for aligning New Focus® modulators. 8-32 and 1/4-20 Threads. Patent Number 5,303,035

The 9071 Four-Axis Tilt Aligner allows you to intuitively align optical tubes that comprise an input and an output (e. g., electro-optic or acousto-optic modulators or lenses). Center one end to the laser beam, then adjust the other until the beam emerges. All motions are independent and connected to a single base, so you won't induce coupled motion while making adjustments. These stages are great for aligning New Focus® modulators. 8-32 and 1/4-20 Threads. Patent Number 5,303,035

Supplier's Site

Technical Specifications

  Newport MKS
Product Category Linear Slides and Linear Stages
Product Number 9071
Product Name Device Alignment Stage, Four-Axis, 3 mm Linear, 8° Angular, 8-32 & 1/4-20
Stroke or X-Axis Travel 0.1181 inch (3 mm)
Unlock Full Specs
to access all available technical data

Similar Products

Air Bearing Stage, Wafer Positioning, DynamYX ® 300 - DYNAMYX300 - Newport MKS
Specs
Stroke or X-Axis Travel 3.78 inch (96 mm)
Y-Axis Travel 13.39 inch (340 mm)
Rated Speed 15.75 in/sec (24 m/min)
View Details
Linear Stage, 0.5 in. Travel, 4-40, 8-32, 1/4-20, Vacuum, No Baseplate - 9066-COM-V - Newport MKS
Specs
Axis Configuration X Axis Only
Stroke or X-Axis Travel 0.5000 inch (12.7 mm)
Device Type Crossed Roller Slide
View Details
XY Linear Stage, Triple Divide, 1 in, X Pico, Y Micro, 8-32,1/4-20 - 9064-XY-PN - Newport MKS
Specs
Axis Configuration X-Y Axes
Stroke or X-Axis Travel 1 inch (25.4 mm)
Rated Speed 7.87E-4 in/sec (0.0012 m/min)
View Details
Optical Post Lab Jack, 3 mm Travel, 4.4 N Load, 8-32 Thread - 9201 - Newport MKS
Specs
Axis Configuration Z Axis Only
Stroke or X-Axis Travel 0.1181 inch (3 mm)
View Details