LECO Corporation Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion Infrared and Thermal Conductivity Detection 836 Series

Description
The ONH836 Oxygen/Nitrogen/Hydr ogen Elemental Analyzer is designed for wide-range measurement of oxygen, nitrogen, and hydrogen content of inorganic materials, ferrous and nonferrous alloys, and refractory materials using the inert gas fusion technique. The instrument features a custom MS Windows®-based software interface designed specifically for touch-screen operation. Developed by combining long-term research with customer feedback, this easy-to-use software gives you complete access to instrument control, analysis settings, diagnostics, reporting, and more—without sacrificing valuable bench space. Cornerstone Mobile option provides access to data, plots, and instrument status from your smart phone, tablet, or desktop computer. Integral Sample Loading Area Minimizes atmospheric contamination during sample introduction Simplifies routine sample drop mechanism maintenance New quick-change disk filter assembly Reliable Automation Available Optional autocleaner available, minimizing need for manual cleaning between samples Optional 20-crucible batch loader available Additional Features and Benefits Boom-mounted touch interface form improved ergonomics and intuitive operation Pressure-compensated and temperature-controll ed gas dose system Novel flowpath plumbing minimizes connections to make/break/leak Compatible with SmartLine® Remote Diagnostics.
Description
The ONH836 Oxygen/Nitrogen/Hydr ogen Elemental Analyzer is designed for wide-range measurement of oxygen, nitrogen, and hydrogen content of inorganic materials, ferrous and nonferrous alloys, and refractory materials using the inert gas fusion technique. The instrument features a custom MS Windows®-based software interface designed specifically for touch-screen operation. Developed by combining long-term research with customer feedback, this easy-to-use software gives you complete access to instrument control, analysis settings, diagnostics, reporting, and more—without sacrificing valuable bench space. Cornerstone Mobile option provides access to data, plots, and instrument status from your smart phone, tablet, or desktop computer. Integral Sample Loading Area Minimizes atmospheric contamination during sample introduction Simplifies routine sample drop mechanism maintenance New quick-change disk filter assembly Reliable Automation Available Optional autocleaner available, minimizing need for manual cleaning between samples Optional 20-crucible batch loader available Additional Features and Benefits Boom-mounted touch interface form improved ergonomics and intuitive operation Pressure-compensated and temperature-controll ed gas dose system Novel flowpath plumbing minimizes connections to make/break/leak Compatible with SmartLine® Remote Diagnostics.

Suppliers

Company
Product
Description
Supplier Links
Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion Infrared and Thermal Conductivity Detection - 836 Series - LECO Corporation
St. Joseph, MI, USA
Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion Infrared and Thermal Conductivity Detection
836 Series
Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion Infrared and Thermal Conductivity Detection 836 Series
The ONH836 Oxygen/Nitrogen/Hydr ogen Elemental Analyzer is designed for wide-range measurement of oxygen, nitrogen, and hydrogen content of inorganic materials, ferrous and nonferrous alloys, and refractory materials using the inert gas fusion technique. The instrument features a custom MS Windows®-based software interface designed specifically for touch-screen operation. Developed by combining long-term research with customer feedback, this easy-to-use software gives you complete access to instrument control, analysis settings, diagnostics, reporting, and more—without sacrificing valuable bench space. Cornerstone Mobile option provides access to data, plots, and instrument status from your smart phone, tablet, or desktop computer. Integral Sample Loading Area Minimizes atmospheric contamination during sample introduction Simplifies routine sample drop mechanism maintenance New quick-change disk filter assembly Reliable Automation Available Optional autocleaner available, minimizing need for manual cleaning between samples Optional 20-crucible batch loader available Additional Features and Benefits Boom-mounted touch interface form improved ergonomics and intuitive operation Pressure-compensated and temperature-controll ed gas dose system Novel flowpath plumbing minimizes connections to make/break/leak Compatible with SmartLine® Remote Diagnostics.

The ONH836 Oxygen/Nitrogen/Hydrogen Elemental Analyzer is designed for wide-range measurement of oxygen, nitrogen, and hydrogen content of inorganic materials, ferrous and nonferrous alloys, and refractory materials using the inert gas fusion technique.

The instrument features a custom MS Windows®-based software interface designed specifically for touch-screen operation. Developed by combining long-term research with customer feedback, this easy-to-use software gives you complete access to instrument control, analysis settings, diagnostics, reporting, and more—without sacrificing valuable bench space.

Cornerstone Mobile option provides access to data, plots, and instrument status from your smart phone, tablet, or desktop computer.

Integral Sample Loading Area

  • Minimizes atmospheric contamination during sample introduction
  • Simplifies routine sample drop mechanism maintenance
  • New quick-change disk filter assembly

Reliable Automation Available

  • Optional autocleaner available, minimizing need for manual cleaning between samples
  • Optional 20-crucible batch loader available

Additional Features and Benefits

  • Boom-mounted touch interface form improved ergonomics and intuitive operation
  • Pressure-compensated and temperature-controlled gas dose system
  • Novel flowpath plumbing minimizes connections to make/break/leak
  • Compatible with SmartLine® Remote Diagnostics.
Supplier's Site

Technical Specifications

  LECO Corporation
Product Category Elemental Analyzers
Product Number 836 Series
Product Name Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion Infrared and Thermal Conductivity Detection
Elements Analyzed Hydrogen (H); Nitrogen (N) / Protein; Oxygen (O)
Unlock Full Specs
to access all available technical data

Similar Products

Inclusion identification and quantification analysis - PoDFA - ABB Measurement & Analytics
Specs
Elements Analyzed Metal / Metalloid
Sample Form Liquid / Slurry Samples
Analysis Method / Detection Technology The PoDFA Technique
View Details
Benchtop XRF Analyzer for RoHS - EA1000AIII - Hitachi High-Tech America
Specs
Elements Analyzed Metal / Metalloid; Element Range : Al - U
Test Media / Material Analyzed Ferrous Metal (Steel, Cast Iron); Nonferrous (Copper, Aluminum); Inorganic Material
Sample Form Solid Samples; Liquid / Slurry Samples
View Details
Oxygen/Nitrogen by Inert Gas Fusion Infrared and Thermal Conductivity Detection - 500 Series - LECO Corporation
Specs
Elements Analyzed Nitrogen (N) / Protein; Oxygen (O)
Test Media / Material Analyzed Inorganic Material
Analysis Method / Detection Technology Inert Gas Fusion (IGF); Infrared Detector (IR Cell); Thermal Conductivity Detector
View Details