Panametrics Chilled Mirror Hygrometer Optica Series

Description
GE’s Optica Series chilled mirror hygrometers offer National Institute of Standards and Technologies (NIST)—traceable humidity, temperature and pressure measurements for the connected generation. Now data is accessible from anywhere, any time, from within a browser over the Internet or from your Intranet. Optica Measures Temperature Relative humidity (% RH) Dew/frost point (Td) Absolute humidity (m/v) Mass mixing ratio (m/m) Volume mixing ratio (v/v) Wet bulb (Tw) Enthalpy (h) Water vapor pressure (e) Pressure Alarm relays Analog outputs
Request a Quote
Description
GE’s Optica Series chilled mirror hygrometers offer National Institute of Standards and Technologies (NIST)—traceable humidity, temperature and pressure measurements for the connected generation. Now data is accessible from anywhere, any time, from within a browser over the Internet or from your Intranet. Optica Measures Temperature Relative humidity (% RH) Dew/frost point (Td) Absolute humidity (m/v) Mass mixing ratio (m/m) Volume mixing ratio (v/v) Wet bulb (Tw) Enthalpy (h) Water vapor pressure (e) Pressure Alarm relays Analog outputs
Request a Quote
Datasheet
Datasheet Summary
Powered by GS/AI

The Optica Series chilled mirror hygrometers provide NIST-traceable measurements of dew point, temperature, and pressure for calibration and precision humidity control. The instruments use a chilled mirror with a rhodium or platinum reflective surface and a thermoelectric cooling module to directly measure dew or frost point with an accuracy of ±0.36°F (±0.2°C), optionally enhanced to ±0.27°F (±0.15°C). A four-wire 100 Ω platinum RTD and a silicon piezoresistive pressure transducer enable calculation of additional humidity parameters such as relative humidity, enthalpy, and absolute humidity. The analyzer features Ethernet connectivity, a 6 MB data logger, Java-based web interface, color VGA or matrix display, and programmable analog outputs. Chilled mirror sensors require a flow rate of 0.5 to 5 SCFH and are field-replaceable. The unit supports multiple voltage inputs and is designed for lab, process, and environmental applications. Benchtop models may include a rack mount bracket.

Datasheet Summary
Powered by GS/AI

The Optica Series chilled mirror hygrometers provide NIST-traceable measurements of dew point, temperature, and pressure for calibration and precision humidity control. The instruments use a chilled mirror with a rhodium or platinum reflective surface and a thermoelectric cooling module to directly measure dew or frost point with an accuracy of ±0.36°F (±0.2°C), optionally enhanced to ±0.27°F (±0.15°C). A four-wire 100 Ω platinum RTD and a silicon piezoresistive pressure transducer enable calculation of additional humidity parameters such as relative humidity, enthalpy, and absolute humidity. The analyzer features Ethernet connectivity, a 6 MB data logger, Java-based web interface, color VGA or matrix display, and programmable analog outputs. Chilled mirror sensors require a flow rate of 0.5 to 5 SCFH and are field-replaceable. The unit supports multiple voltage inputs and is designed for lab, process, and environmental applications. Benchtop models may include a rack mount bracket.

Suppliers

Company
Product
Description
Supplier Links
Chilled Mirror Hygrometer - Optica Series - Panametrics
Billerica, MA, United States
Chilled Mirror Hygrometer
Optica Series
Chilled Mirror Hygrometer Optica Series
GE’s Optica Series chilled mirror hygrometers offer National Institute of Standards and Technologies (NIST)—traceable humidity, temperature and pressure measurements for the connected generation. Now data is accessible from anywhere, any time, from within a browser over the Internet or from your Intranet. Optica Measures Temperature Relative humidity (% RH) Dew/frost point (Td) Absolute humidity (m/v) Mass mixing ratio (m/m) Volume mixing ratio (v/v) Wet bulb (Tw) Enthalpy (h) Water vapor pressure (e) Pressure Alarm relays Analog outputs

GE’s Optica Series chilled mirror hygrometers offer National Institute of Standards and Technologies (NIST)—traceable humidity, temperature and pressure measurements for the connected generation. Now data is accessible from anywhere, any time, from within a browser over the Internet or from your Intranet.

Optica Measures

  • Temperature
  • Relative humidity (% RH)
  • Dew/frost point (Td)
  • Absolute humidity (m/v)
  • Mass mixing ratio (m/m)
  • Volume mixing ratio (v/v)
  • Wet bulb (Tw)
  • Enthalpy (h)
  • Water vapor pressure (e)
  • Pressure
  • Alarm relays
  • Analog outputs
Supplier's Site Datasheet

Technical Specifications

  Panametrics
Product Category Moisture Meters
Product Number Optica Series
Product Name Chilled Mirror Hygrometer
Technology ChillMirror
Application Moisture / Water Content in Gases / Air
Features Datalogger
Variables Measured DewPoint; Pressure; Temperature
Form Factor Instrument
Unlock Full Specs
to access all available technical data

Similar Products

Trace Moisture Analyzer - moisture.IQ - Panametrics
Specs
Application Moisture / Water Content in Fuel / Liquids; Moisture / Water Content in Gases / Air
Features Datalogger
Variables Measured DewPoint; Pressure (optional feature); Temperature (optional feature)
View Details
Moisture Analyzer - air.IQ - Panametrics
Specs
Technology Aluminum Oxide
Application Moisture / Water Content in Gases / Air
Features Datalogger
View Details
Aluminum Oxide Moisture Transmitter - HygroPro II - Panametrics
Specs
Technology Aluminum Oxide
Application Moisture / Water Content in Gases / Air
Variables Measured Relative Humidity; DewPoint (optional feature); Pressure (optional feature); Temperature
View Details
Aluminum Oxide Moisture Transmitter - HygroPro XP - Panametrics
Specs
Technology Aluminum Oxide
Application Moisture / Water Content in Gases / Air
Variables Measured Relative Humidity; DewPoint (optional feature); Pressure (optional feature); Temperature
View Details