The File based HDLC Record/Playback (Hdlcfunc) module is an optional application that allows HDLC Traffic Capture/Playback. It also allows transmission/recepti
on of *.HDL frames files located on the server and on client.
Ability to Tx and Rx HDLC frames (using WCS) on 12 ports simultaneously on full bandwidth TS 0-23 in a 12 ports system.
Ability to Tx on 6 ports and Rx on 6 ports simultaneously on full bandwidth (TS 0-23), in a 12 ports system
Ability to Tx on 8 ports and Rx on 8 ports simultaneously on 8TS pipe per card - 512 kbps pipe (TS 0-7) in a 16 ports system
Ability to Tx on 6 ports and Rx on 6 ports simultaneously on 16 TS pipe per card (TS0-15 1024kbps) in a 12 ports system
Ability to Tx on 46 individual TS and Rx on 46 individual TS (64K/56K) with hundred flags in a 4 ports system
Ability to Tx on 31 individual TS and Rx on 31 individual TS (64K/56K) with Ten flags in a 4 ports system
Ability to Tx on 25 individual TS and Rx on 25 individual TS (64K/56k) with one flag in a 4 ports system
The application allows:
Displays the command syntax.
Receiving HDLC frames in HDL files located on the server.
Transmitting HDLC frames from an HDL file located on the server.
Receiving HDLC frames in HDL files located on the client.
Transmitting HDLC frames from an HDL file located on the client.
Important Syntax Notation Notes
Whenever HdlcFuncT(E)1:Xxx is used in a command syntax implies that HdlcFuncT1: XXX must be used for T1 cards and HdlcFuncE1:Xxx must be used for E1 cards
All the parameters must be entered in the order defined by the syntax. [parm] means that the parameter is optional and can be omitted.
Parameters in capital like CONT, EOF, and FLAGS must be entered as is.
Parm1|Parm2|Parm3 - parameter is mandatory, one of the choices Parm1, Parm2 or Parm3 must be specified
Sub channels are specified as 0xSM - sub-channel mask, for example 0x01 or 0xFE or 0xC0
Parameters specified in a syntax with all small letters usually need to be substituted by a specific value, while parameters in all capitals must be entered as they are specified.
The File based HDLC Record/Playback (Hdlcfunc) module is an optional application that allows HDLC Traffic Capture/Playback. It also allows transmission/reception of *.HDL frames files located on the server and on client.
- Ability to Tx and Rx HDLC frames (using WCS) on 12 ports simultaneously on full bandwidth TS 0-23 in a 12 ports system.
- Ability to Tx on 6 ports and Rx on 6 ports simultaneously on full bandwidth (TS 0-23), in a 12 ports system
- Ability to Tx on 8 ports and Rx on 8 ports simultaneously on 8TS pipe per card - 512 kbps pipe (TS 0-7) in a 16 ports system
- Ability to Tx on 6 ports and Rx on 6 ports simultaneously on 16 TS pipe per card (TS0-15 1024kbps) in a 12 ports system
- Ability to Tx on 46 individual TS and Rx on 46 individual TS (64K/56K) with hundred flags in a 4 ports system
- Ability to Tx on 31 individual TS and Rx on 31 individual TS (64K/56K) with Ten flags in a 4 ports system
- Ability to Tx on 25 individual TS and Rx on 25 individual TS (64K/56k) with one flag in a 4 ports system
The application allows:
- Displays the command syntax.
- Receiving HDLC frames in HDL files located on the server.
- Transmitting HDLC frames from an HDL file located on the server.
- Receiving HDLC frames in HDL files located on the client.
- Transmitting HDLC frames from an HDL file located on the client.
Important Syntax Notation Notes
Whenever HdlcFuncT(E)1:Xxx is used in a command syntax implies that HdlcFuncT1: XXX must be used for T1 cards and HdlcFuncE1:Xxx must be used for E1 cards
All the parameters must be entered in the order defined by the syntax. [parm] means that the parameter is optional and can be omitted.
Parameters in capital like CONT, EOF, and FLAGS must be entered as is.
Parm1|Parm2|Parm3 - parameter is mandatory, one of the choices Parm1, Parm2 or Parm3 must be specified
Sub channels are specified as 0xSM - sub-channel mask, for example 0x01 or 0xFE or 0xC0
Parameters specified in a syntax with all small letters usually need to be substituted by a specific value, while parameters in all capitals must be entered as they are specified.