Time Mark Corporation Interval/Lockout Timer Model 392-H

Description
The Model 392 Interval Lockout Timer is useful when you wish to de-energize the relay for a set period of time. Power is applied to the coil all the time. The Dry contact must close the initiate switch and re-open to energize the relay for the On time setting. At the end of the On time, the relay will de-energize and remain de-energized for the lockout time period. Closing and re-opening the initiate switch during the timing has no effect on the operation of the relay. At the end of the Lockout time the relay can be operated as before. An SG version of this model is available using silver with gold flash contacts. The Model 392 is UL Recognized and CSA Certified.
Description
The Model 392 Interval Lockout Timer is useful when you wish to de-energize the relay for a set period of time. Power is applied to the coil all the time. The Dry contact must close the initiate switch and re-open to energize the relay for the On time setting. At the end of the On time, the relay will de-energize and remain de-energized for the lockout time period. Closing and re-opening the initiate switch during the timing has no effect on the operation of the relay. At the end of the Lockout time the relay can be operated as before. An SG version of this model is available using silver with gold flash contacts. The Model 392 is UL Recognized and CSA Certified.

Suppliers

Company
Product
Description
Supplier Links
Interval/Lockout Timer - Model 392-H - Time Mark Corporation
Tulsa, OK, USA
Interval/Lockout Timer
Model 392-H
Interval/Lockout Timer Model 392-H
The Model 392 Interval Lockout Timer is useful when you wish to de-energize the relay for a set period of time. Power is applied to the coil all the time. The Dry contact must close the initiate switch and re-open to energize the relay for the On time setting. At the end of the On time, the relay will de-energize and remain de-energized for the lockout time period. Closing and re-opening the initiate switch during the timing has no effect on the operation of the relay. At the end of the Lockout time the relay can be operated as before. An SG version of this model is available using silver with gold flash contacts. The Model 392 is UL Recognized and CSA Certified.

The Model 392 Interval Lockout Timer is useful when you wish to de-energize the relay for a set period of time. Power is applied to the coil all the time. The Dry contact must close the initiate switch and re-open to energize the relay for the On time setting. At the end of the On time, the relay will de-energize and remain de-energized for the lockout time period. Closing and re-opening the initiate switch during the timing has no effect on the operation of the relay. At the end of the Lockout time the relay can be operated as before. An SG version of this model is available using silver with gold flash contacts. The Model 392 is UL Recognized and CSA Certified.

Supplier's Site

Technical Specifications

  Time Mark Corporation
Product Category Time Delay Relays
Product Number Model 392-H
Product Name Interval/Lockout Timer
Time Range Multiple Time Ranges
Mounting Socket or Plug-in Style
Approvals / Ratings UL, CSA
Operating Temperature -20 to 140 F (-28.89 to 60 C)
Timer Type Interval
Unlock Full Specs
to access all available technical data

Similar Products

Type 12.62 - Digital time switch 16A - 126282300000 - Finder S.p.A. con unico socio
Specs
Pole and Throw Specifications Double Pole, Double Throw (DPDT)
View Details
 - 260555 - RS Components, Ltd.
RS Components, Ltd.
Specs
Time Ranges Seconds
Timer Type Off-Delay
Function Type Single Function
View Details
Time Delay Relays - 1423153-7 - TE Connectivity
Specs
Mounting Chassis Mount
Operating Temperature -67 to 185 F (-55 to 85 C)
Repeat Accuracy 5 +/- %
View Details
Mini Plug-in Timing Relay - 700-HNC44BZ25 - Allen-Bradley / Rockwell Automation
Allen-Bradley / Rockwell Automation
Specs
Timer Type ON-Delay
Function Type Multi-function
Pole and Throw Specifications 4PDT
View Details