RESON TC4043

Description
The TC4043 Miniature hydrophone offers a wide frequency range from 2Hz to over 160kHz. The frequency response is flat from 2Hz to 100kHz. The hydrophones directivity is typically omnidirectional up to 100kHz. The TC4043 incorporates a high quality 10dB low-noise preamplifier that provides optimal conditions for signal transmission over long cables. This preamplifiers features an insert voltage calibration circuit allowing the hydrophone to be reliably tested. The hydrophone is supplied with an integral 10m for conductor shielded cable. The cable is terminated with a four pole LEMO connector.
Description
The TC4043 Miniature hydrophone offers a wide frequency range from 2Hz to over 160kHz. The frequency response is flat from 2Hz to 100kHz. The hydrophones directivity is typically omnidirectional up to 100kHz. The TC4043 incorporates a high quality 10dB low-noise preamplifier that provides optimal conditions for signal transmission over long cables. This preamplifiers features an insert voltage calibration circuit allowing the hydrophone to be reliably tested. The hydrophone is supplied with an integral 10m for conductor shielded cable. The cable is terminated with a four pole LEMO connector.

Suppliers

Company
Product
Description
Supplier Links
TC4043 -  - RESON
Goleta, CA, USA
TC4043
TC4043
The TC4043 Miniature hydrophone offers a wide frequency range from 2Hz to over 160kHz. The frequency response is flat from 2Hz to 100kHz. The hydrophones directivity is typically omnidirectional up to 100kHz. The TC4043 incorporates a high quality 10dB low-noise preamplifier that provides optimal conditions for signal transmission over long cables. This preamplifiers features an insert voltage calibration circuit allowing the hydrophone to be reliably tested. The hydrophone is supplied with an integral 10m for conductor shielded cable. The cable is terminated with a four pole LEMO connector.

The TC4043 Miniature hydrophone offers a wide frequency range from 2Hz to over 160kHz. The frequency response is flat from 2Hz to 100kHz. The hydrophones directivity is typically omnidirectional up to 100kHz. The TC4043 incorporates a high quality 10dB low-noise preamplifier that provides optimal conditions for signal transmission over long cables. This preamplifiers features an insert voltage calibration circuit allowing the hydrophone to be reliably tested. The hydrophone is supplied with an integral 10m for conductor shielded cable. The cable is terminated with a four pole LEMO connector.

Technical Specifications

  RESON
Product Category Hydrophones
Product Name TC4043
Frequency Response 2 to 160000 Hz
Sensitivity -201 dB re V/µPa
Maximum Depth 700 m (2297 ft)
Features Integral Pre-amplifier
Unlock Full Specs
to access all available technical data

Similar Products

H23-130 Internally amplified hydrophone - H23-130 - Wilcoxon Sensing Technologies
Specs
Frequency Response 5 to 150000 Hz
Sensitivity -182 dB re V/µPa
Maximum Depth 680 m (2231 ft)
View Details
Specs
Frequency Response 10000 to 800000 Hz
Sensitivity -228 dB re V/µPa
Maximum Depth 20 m (65.62 ft)
View Details
Digital Hydrophone -  - Cable & Supplies, Inc.
Cable & Supplies, Inc.
Specs
Frequency Response 7 to 80000 Hz
Features Integral Pre-amplifier
Diameter 43 mm (1.69 inch)
View Details
Hydrophones Chain, 24-Channels - HBC24 - M.A.E. Apparecchiature Elettroniche srl
M.A.E. Apparecchiature Elettroniche srl
Specs
Frequency Response 5 to 2000 Hz
Sensitivity -201 dB re V/µPa
Maximum Depth 3048 m (10000 ft)
View Details