Taylor Dynamometer custom engineers Water Recirculation / Cooling Systems for single test cells or complete test facilities with multiple test cells and multiple heat source requirements. Water systems can be designed with above or below ground bulk water storage for use with a variety of cooling devices. The Evaporative Cooling Tower is the most cost effective solution in most cases.
Taylor Water Recirculation / Cooling System Benefits:
Reduced dynamometer operating costs through water conservation
Reduced dynamometer maintenance costs with controlled, high- quality water supply
Assured environmental-friend
liness by discharging through evaporation rather than drainage
Assured dynamometer performance due to proper water pressure, volume, and cooling
The Water Recirculating / Cooling Systems designed by Taylor are intended primarily for use with dynamometers, though they can be used to conserve water with any heat-generating, water-cooled process equipment as well. Our engineers can easily accommodate your needs and ensure sufficient capacity is designed into the system.
Water Recirculation System (WRS) from Taylor Includes:
WRS Command and Control Center: The WRS command center contains the system controller, motor starters and accessory connections. The WRS command center can be programmed for the desired system start-up temperatures, failure notification, emergency shutdown and many other convenient options to best suit your application.
Pumps and motors: Taylor Dynamometer will supply you with the best possible pumps for the application requirements. Some of the different styles of pumps used are centrifugal, vertical turbine, and centrifugal self-priming. All pumps are sized specifically to the application, related cooling volume and pressure requirements for proper system operation.
Evaporative Cooling Tower, Chiller, Heat Exchanger or Radiator: The Evaporative Cooling Towers, Chillers, Heat Exchangers and Radiators used by Taylor are all designed for optimum heat transfer and efficiency. All components used are suitable for outdoor service and may be installed on an unobstructed rooftop or on ground level. Systems may also be designed for indoor installation.
Specifications, Installation requirements, piping schematics: Taylor Dynamometer will provide specifications for each pump, motor and cooling device along with informational forms and Installation Information.
Taylor Dynamometer custom engineers Water Recirculation / Cooling Systems for single test cells or complete test facilities with multiple test cells and multiple heat source requirements. Water systems can be designed with above or below ground bulk water storage for use with a variety of cooling devices. The Evaporative Cooling Tower is the most cost effective solution in most cases.
Taylor Water Recirculation / Cooling System Benefits:
- Reduced dynamometer operating costs through water conservation
- Reduced dynamometer maintenance costs with controlled, high- quality water supply
- Assured environmental-friendliness by discharging through evaporation rather than drainage
- Assured dynamometer performance due to proper water pressure, volume, and cooling
The Water Recirculating / Cooling Systems designed by Taylor are intended primarily for use with dynamometers, though they can be used to conserve water with any heat-generating, water-cooled process equipment as well. Our engineers can easily accommodate your needs and ensure sufficient capacity is designed into the system.
Water Recirculation System (WRS) from Taylor Includes:
- WRS Command and Control Center: The WRS command center contains the system controller, motor starters and accessory connections. The WRS command center can be programmed for the desired system start-up temperatures, failure notification, emergency shutdown and many other convenient options to best suit your application.
- Pumps and motors: Taylor Dynamometer will supply you with the best possible pumps for the application requirements. Some of the different styles of pumps used are centrifugal, vertical turbine, and centrifugal self-priming. All pumps are sized specifically to the application, related cooling volume and pressure requirements for proper system operation.
- Evaporative Cooling Tower, Chiller, Heat Exchanger or Radiator: The Evaporative Cooling Towers, Chillers, Heat Exchangers and Radiators used by Taylor are all designed for optimum heat transfer and efficiency. All components used are suitable for outdoor service and may be installed on an unobstructed rooftop or on ground level. Systems may also be designed for indoor installation.
- Specifications, Installation requirements, piping schematics: Taylor Dynamometer will provide specifications for each pump, motor and cooling device along with informational forms and Installation Information.