Taylor Dynamometer, Inc. Emissions Gas Analyzer

Description
Taylor Dynamometer is proud to offer a cost-effective emissions analyzer for use with Taylor’s DynPro data acquisition and control system. The system offers superior functionality and an elegantly simple design for a seamless integration with the DynPro system. The Emissions Gas Analyzer uses a dual-head pump, unique onepiece particulate filter and water separator, protected hoses and a sample probe for open exhaust systems. Closed exhaust systems will require fittings (customer supplied) to be inserted into the exhaust stream. Our emissions analyzers are intended to be located near (4 to 6 feet) the source of emissions to eliminate the need for heated sample lines. Intelligent Warm-Up Mechanism The Emissions Gas Analyzer provided by Taylor Dynamometer incorporates an "intelligent" warm-up mechanism that allows the analyzer to learn its specific warm-up characteristics. This feature allows the analyzer to self-correct and compensate for its immediate environment as well as temperature changes that may cause measurement drift. The analyzer is ready for use in as little as 20 seconds.
Description
Taylor Dynamometer is proud to offer a cost-effective emissions analyzer for use with Taylor’s DynPro data acquisition and control system. The system offers superior functionality and an elegantly simple design for a seamless integration with the DynPro system. The Emissions Gas Analyzer uses a dual-head pump, unique onepiece particulate filter and water separator, protected hoses and a sample probe for open exhaust systems. Closed exhaust systems will require fittings (customer supplied) to be inserted into the exhaust stream. Our emissions analyzers are intended to be located near (4 to 6 feet) the source of emissions to eliminate the need for heated sample lines. Intelligent Warm-Up Mechanism The Emissions Gas Analyzer provided by Taylor Dynamometer incorporates an "intelligent" warm-up mechanism that allows the analyzer to learn its specific warm-up characteristics. This feature allows the analyzer to self-correct and compensate for its immediate environment as well as temperature changes that may cause measurement drift. The analyzer is ready for use in as little as 20 seconds.

Suppliers

Company
Product
Description
Supplier Links
Emissions Gas Analyzer -  - Taylor Dynamometer, Inc.
Milwaukee, WI, USA
Emissions Gas Analyzer
Emissions Gas Analyzer
Taylor Dynamometer is proud to offer a cost-effective emissions analyzer for use with Taylor’s DynPro data acquisition and control system. The system offers superior functionality and an elegantly simple design for a seamless integration with the DynPro system. The Emissions Gas Analyzer uses a dual-head pump, unique onepiece particulate filter and water separator, protected hoses and a sample probe for open exhaust systems. Closed exhaust systems will require fittings (customer supplied) to be inserted into the exhaust stream. Our emissions analyzers are intended to be located near (4 to 6 feet) the source of emissions to eliminate the need for heated sample lines. Intelligent Warm-Up Mechanism The Emissions Gas Analyzer provided by Taylor Dynamometer incorporates an "intelligent" warm-up mechanism that allows the analyzer to learn its specific warm-up characteristics. This feature allows the analyzer to self-correct and compensate for its immediate environment as well as temperature changes that may cause measurement drift. The analyzer is ready for use in as little as 20 seconds.

Taylor Dynamometer is proud to offer a cost-effective emissions analyzer for use with Taylor’s DynPro data acquisition and control system. The system offers superior functionality and an elegantly simple design for a seamless integration with the DynPro system.

The Emissions Gas Analyzer uses a dual-head pump, unique onepiece particulate filter and water separator, protected hoses and a sample probe for open exhaust systems. Closed exhaust systems will require fittings (customer supplied) to be inserted into the exhaust stream. Our emissions analyzers are intended to be located near (4 to 6 feet) the source of emissions to eliminate the need for heated sample lines.

Intelligent Warm-Up Mechanism

The Emissions Gas Analyzer provided by Taylor Dynamometer incorporates an "intelligent" warm-up mechanism that allows the analyzer to learn its specific warm-up characteristics. This feature allows the analyzer to self-correct and compensate for its immediate environment as well as temperature changes that may cause measurement drift. The analyzer is ready for use in as little as 20 seconds.

Supplier's Site

Technical Specifications

  Taylor Dynamometer, Inc.
Product Category Gas Instruments
Product Name Emissions Gas Analyzer
Unlock Full Specs
to access all available technical data

Similar Products

Vapor Flammability Analyzer - PrevEx Model SNR702 - Control Instruments Corp.
Specs
Measurement Type %LEL or %LFL
Application Ambient Air Monitoring; Process Gas
Gas Types Combustible; Hydrocarbons; (0-100% LFL); H2; (0-100% LFL); Methane (CH4) / Natural Gas; (0-100% LFL)
View Details
Infrared Gas Analyzer - ZPAH/ZPA1 Series - Fuji Electric Corp. of America
Fuji Electric Corp. of America
Specs
Application Process Gas
Gas Types CO2; (0-500ppm); CO; (0-500ppm); Methane (CH4) / Natural Gas; (0-1000ppm); SO2; (0-500ppm)
Electrical Outputs Current
View Details
Hydrogen Sulfide (H2S) Combustible Fixed Gas Detector (0-100ppm) -  - CO2Meter.com
Specs
Gas Types Combustible; (Combustible Fixed Gas Detectors - Hydrogen Sulfide (H2S) Combustible Fixed Gas Detector (0-100ppm))
Number of Gases Monitored Single
Operating Temperature -30 to 122 F (-34 to 50 C)
View Details
Multiple Impurity Lab Analyzer - 9600L - C.I. Analytics, Inc.
Specs
Measurement Type %Volume
Instrument Type Analyzer
Sensor Technology Advanced dry colorimetry Sensi-Tape® and Tri-Color adaptive optics block
View Details