Siemens Process Instrumentation BACnet EtherNet/IP Gateway

Description
The Siemens ProtoAir gateway provides BACnet and EtherNet/IP communications for Siemens electromagnetic, Coriolis, and clamp-on ultrasonic flow meters. It is a cost effective interface available either as a stand-alone component for installation in a control panel or installed within a NEMA 4 enclosure with a power supply for field mounted applications. The gateway has two (2) serial ports, one (1) Ethernet port, and a wireless access point. One serial port connects with the flow meters via an RS-485 network and communicates Modbus RTU. The second serial port is for connection with an Automation network via BACnet MS/TP. The Ethernet port also connects with an Automation network via BACnet/IP. The gateway also serves as an EtherNet/IP adapter. The gateway supports a web server for setup and diagnostics. For setup, the user specifies the communication protocol and the flow meter profile. Profiles are pre-configured and map the instrument Modbus data to BACnet or EtherNet/ IP communication objects. The profiles provide process variable, alarm, and instrument diagnostic data. The web server is accessible via the Ethernet port or via the wireless access point. The gateway supports network security.
Datasheet
Description
The Siemens ProtoAir gateway provides BACnet and EtherNet/IP communications for Siemens electromagnetic, Coriolis, and clamp-on ultrasonic flow meters. It is a cost effective interface available either as a stand-alone component for installation in a control panel or installed within a NEMA 4 enclosure with a power supply for field mounted applications. The gateway has two (2) serial ports, one (1) Ethernet port, and a wireless access point. One serial port connects with the flow meters via an RS-485 network and communicates Modbus RTU. The second serial port is for connection with an Automation network via BACnet MS/TP. The Ethernet port also connects with an Automation network via BACnet/IP. The gateway also serves as an EtherNet/IP adapter. The gateway supports a web server for setup and diagnostics. For setup, the user specifies the communication protocol and the flow meter profile. Profiles are pre-configured and map the instrument Modbus data to BACnet or EtherNet/ IP communication objects. The profiles provide process variable, alarm, and instrument diagnostic data. The web server is accessible via the Ethernet port or via the wireless access point. The gateway supports network security.
Datasheet

Suppliers

Company
Product
Description
Supplier Links
BACnet EtherNet/IP Gateway -  - Siemens Process Instrumentation
Harleysville, PA, United States
BACnet EtherNet/IP Gateway
BACnet EtherNet/IP Gateway
The Siemens ProtoAir gateway provides BACnet and EtherNet/IP communications for Siemens electromagnetic, Coriolis, and clamp-on ultrasonic flow meters. It is a cost effective interface available either as a stand-alone component for installation in a control panel or installed within a NEMA 4 enclosure with a power supply for field mounted applications. The gateway has two (2) serial ports, one (1) Ethernet port, and a wireless access point. One serial port connects with the flow meters via an RS-485 network and communicates Modbus RTU. The second serial port is for connection with an Automation network via BACnet MS/TP. The Ethernet port also connects with an Automation network via BACnet/IP. The gateway also serves as an EtherNet/IP adapter. The gateway supports a web server for setup and diagnostics. For setup, the user specifies the communication protocol and the flow meter profile. Profiles are pre-configured and map the instrument Modbus data to BACnet or EtherNet/ IP communication objects. The profiles provide process variable, alarm, and instrument diagnostic data. The web server is accessible via the Ethernet port or via the wireless access point. The gateway supports network security.

The Siemens ProtoAir gateway provides BACnet and EtherNet/IP communications for Siemens electromagnetic, Coriolis, and clamp-on ultrasonic flow meters. It is a cost effective interface available either as a stand-alone component for installation in a control panel or installed within a NEMA 4 enclosure with a power supply for field mounted applications.

The gateway has two (2) serial ports, one (1) Ethernet port, and a wireless access point. One serial port connects with the flow meters via an RS-485 network and communicates Modbus RTU. The second serial port is for connection with an Automation network via BACnet MS/TP. The Ethernet port also connects with an Automation network via BACnet/IP. The gateway also serves as an EtherNet/IP adapter.

The gateway supports a web server for setup and diagnostics. For setup, the user specifies the communication protocol and the flow meter profile. Profiles are pre-configured and map the instrument Modbus data to BACnet or EtherNet/ IP communication objects. The profiles provide process variable, alarm, and instrument diagnostic data. The web server is accessible via the Ethernet port or via the wireless access point. The gateway supports network security.

Supplier's Site Datasheet

Technical Specifications

  Siemens Process Instrumentation
Product Category Network Equipment
Product Name BACnet EtherNet/IP Gateway
Network Equipment Gateway
Network Media Wireless
Protocol / Network BACnet/IP, BACnet MS/TP, Ethernet/IP
Unlock Full Specs
to access all available technical data

Similar Products

Port Extender for 75 Ohm VNAs - PE0312-75 - Copper Mountain Technologies
Copper Mountain Technologies
Specs
Network Equipment Repeater
Number of Ports 12 #
View Details
10 Gbit Ethernet SFP+, 850nm multimode - 1-G065 - Hottinger Brüel & Kjær A/S
Specs
Network Equipment Transceiver
View Details
Switches, Hubs - BB-ESW208-2MT-T-ND - DigiKey
Specs
Network Equipment Switch
Ports / Interfaces RJ45, ST
Number of Ports 8 #
View Details