Seaward Group USA Calibration Resistor CR/10

Description
This range of low cost 4 terminal calibration resistors combine high accuracy, class 0.02, long term stability and permanence of calibration in a compact unit. Constructed using carefully selected low temperature coefficient Manganin or Zeranin wire, depending upon value and mounted to ensure mechanical stability, these resistors will provide a cost effective addition to any laboratory or workshop. Typical applications include calibration referene, accurate measurement instrument calibration, and accurate shunt resistors.
Description
This range of low cost 4 terminal calibration resistors combine high accuracy, class 0.02, long term stability and permanence of calibration in a compact unit. Constructed using carefully selected low temperature coefficient Manganin or Zeranin wire, depending upon value and mounted to ensure mechanical stability, these resistors will provide a cost effective addition to any laboratory or workshop. Typical applications include calibration referene, accurate measurement instrument calibration, and accurate shunt resistors.

Suppliers

Company
Product
Description
Supplier Links
Tampa, FL, USA
Calibration Resistor
CR/10
Calibration Resistor CR/10
This range of low cost 4 terminal calibration resistors combine high accuracy, class 0.02, long term stability and permanence of calibration in a compact unit. Constructed using carefully selected low temperature coefficient Manganin or Zeranin wire, depending upon value and mounted to ensure mechanical stability, these resistors will provide a cost effective addition to any laboratory or workshop. Typical applications include calibration referene, accurate measurement instrument calibration, and accurate shunt resistors.

This range of low cost 4 terminal calibration resistors combine high accuracy, class 0.02, long term stability and permanence of calibration in a compact unit. Constructed using carefully selected low temperature coefficient Manganin or Zeranin wire, depending upon value and mounted to ensure mechanical stability, these resistors will provide a cost effective addition to any laboratory or workshop. Typical applications include calibration referene, accurate measurement instrument calibration, and accurate shunt resistors.

Technical Specifications

  Seaward Group USA
Product Category Calibration Instruments
Product Number CR/10
Product Name Calibration Resistor
Calibration Signal DC Current
Unlock Full Specs
to access all available technical data

Similar Products

Continuous Emissions Monitoring Calibration System - Series 2020 CEMCS - Environics, Inc.
Specs
Calibrator Style Portable (optional feature); Fixed
AC Voltage Range 110 to 220 volts
Description (Voltage) 110 to 240 VAC, 50/60 Hz
View Details
Multifunction Calibrator - PCE-123 - PCE Instruments / PCE Americas Inc.
PCE Instruments / PCE Americas Inc.
Specs
Calibrator Style Handheld
Calibration Signal DC Voltage; DC Current; Signal / Waveform Generator Output
DC Voltage Range 0.0 to 1 volts
View Details
Pressure Calibrators - 2534992 - RS Components, Ltd.
Specs
Calibrator Style Battery Powered
Environmental Properties Pressure / Vacuum
View Details
Temperature Calibration Source - Landcal - LAND
Specs
Calibrator Style Fixed
Environmental Properties Thermocouple
Digital Interface Serial Interface