SAE International ELECTROMAGNETIC INTERFERENCE MEASUREMENT ANTENNAS; STANDARD CALIBRATION METHOD ARP958A

Description
This SAE Aerospace Recommended Practice (ARP) outlines a standard method for the checkout and calibration of electromagnetic interference measurement antennas. Its application is for use when measuring a source 1 m from the antenna in a shield room versus a source at a greater distance (far field). This is the typical distance used in performing military EMC testing. Thus, this is a method of calibration. Shield room characteristics are not considered. It does not address an unknown distributed source. Yet it is close to reality since it is based on another antenna that represents a distributed source. This document presents a technique to determine antenna factors for antennas used primarily in performing measurements in accordance with 2.1 and 2.2 .
Description
This SAE Aerospace Recommended Practice (ARP) outlines a standard method for the checkout and calibration of electromagnetic interference measurement antennas. Its application is for use when measuring a source 1 m from the antenna in a shield room versus a source at a greater distance (far field). This is the typical distance used in performing military EMC testing. Thus, this is a method of calibration. Shield room characteristics are not considered. It does not address an unknown distributed source. Yet it is close to reality since it is based on another antenna that represents a distributed source. This document presents a technique to determine antenna factors for antennas used primarily in performing measurements in accordance with 2.1 and 2.2 .

Suppliers

Company
Product
Description
Supplier Links
ELECTROMAGNETIC INTERFERENCE MEASUREMENT ANTENNAS; STANDARD CALIBRATION METHOD - ARP958A - SAE International
Warrendale, PA, United States
ELECTROMAGNETIC INTERFERENCE MEASUREMENT ANTENNAS; STANDARD CALIBRATION METHOD
ARP958A
ELECTROMAGNETIC INTERFERENCE MEASUREMENT ANTENNAS; STANDARD CALIBRATION METHOD ARP958A
This SAE Aerospace Recommended Practice (ARP) outlines a standard method for the checkout and calibration of electromagnetic interference measurement antennas. Its application is for use when measuring a source 1 m from the antenna in a shield room versus a source at a greater distance (far field). This is the typical distance used in performing military EMC testing. Thus, this is a method of calibration. Shield room characteristics are not considered. It does not address an unknown distributed source. Yet it is close to reality since it is based on another antenna that represents a distributed source. This document presents a technique to determine antenna factors for antennas used primarily in performing measurements in accordance with 2.1 and 2.2 .

This SAE Aerospace Recommended Practice (ARP) outlines a standard method for the checkout and calibration of electromagnetic interference measurement antennas. Its application is for use when measuring a source 1 m from the antenna in a shield room versus a source at a greater distance (far field). This is the typical distance used in performing military EMC testing. Thus, this is a method of calibration. Shield room characteristics are not considered. It does not address an unknown distributed source. Yet it is close to reality since it is based on another antenna that represents a distributed source. This document presents a technique to determine antenna factors for antennas used primarily in performing measurements in accordance with 2.1 and 2.2 .

Supplier's Site

Technical Specifications

  SAE International
Product Category Standards and Technical Documents
Product Number ARP958A
Product Name ELECTROMAGNETIC INTERFERENCE MEASUREMENT ANTENNAS; STANDARD CALIBRATION METHOD
Unlock Full Specs
to access all available technical data

Similar Products