This test describes a self-checking procedure for the determination of particulate contaminant five microns or greater in size in hydraulic fluids by the particle count method. A maximum variation of two to one (\u00b133% of the average of two runs) in results should be expected for replicate counts on the same sample, providing that the procedure is followed closely and the precautions presented on pages 10 and 11 of the procedure, regarding manipulation, check samples and self-checking aspects, are observed.
Description
This test describes a self-checking procedure for the determination of particulate contaminant five microns or greater in size in hydraulic fluids by the particle count method. A maximum variation of two to one (\u00b133% of the average of two runs) in results should be expected for replicate counts on the same sample, providing that the procedure is followed closely and the precautions presented on pages 10 and 11 of the procedure, regarding manipulation, check samples and self-checking aspects, are observed.

Suppliers

Company
Product
Description
Supplier Links
PROCEDURE FOR THE DETERMINATION OF PARTICULATE CONTAMINATION OF HYDRAULIC FLUIDS BY THE PARTICLE COUNT METHOD - ARP598 - SAE International
Warrendale, PA, United States
PROCEDURE FOR THE DETERMINATION OF PARTICULATE CONTAMINATION OF HYDRAULIC FLUIDS BY THE PARTICLE COUNT METHOD
ARP598
PROCEDURE FOR THE DETERMINATION OF PARTICULATE CONTAMINATION OF HYDRAULIC FLUIDS BY THE PARTICLE COUNT METHOD ARP598
This test describes a self-checking procedure for the determination of particulate contaminant five microns or greater in size in hydraulic fluids by the particle count method. A maximum variation of two to one (\u00b133% of the average of two runs) in results should be expected for replicate counts on the same sample, providing that the procedure is followed closely and the precautions presented on pages 10 and 11 of the procedure, regarding manipulation, check samples and self-checking aspects, are observed.

This test describes a self-checking procedure for the determination of particulate contaminant five microns or greater in size in hydraulic fluids by the particle count method. A maximum variation of two to one (\u00b133% of the average of two runs) in results should be expected for replicate counts on the same sample, providing that the procedure is followed closely and the precautions presented on pages 10 and 11 of the procedure, regarding manipulation, check samples and self-checking aspects, are observed.

Supplier's Site

Technical Specifications

  SAE International
Product Category Standards and Technical Documents
Product Number ARP598
Product Name PROCEDURE FOR THE DETERMINATION OF PARTICULATE CONTAMINATION OF HYDRAULIC FLUIDS BY THE PARTICLE COUNT METHOD
Unlock Full Specs
to access all available technical data

Similar Products